User's Manual Part 2

DSPbR Series User’s Manual
Document Number 00000.B Page 21/75
number and if there are corresponding RFFE and RFBE board configuration files from a previous module or
saved configuration, the inserted modules configuration will be updated by the CSC accordingly.
A label bearing the respective module’s model number, version and serial number identifies each module. This
label is adhered to the side of the module and is not visible without removing the module from the slot.
A user definable removable yellow plastic labelling system has been provided on the external surface of the
BPFM bolted to the RFFE and RFBE modules to assist the user to identify allocated ports once the user has
configured the DSPbR using the web browser.
3.3.1 PSU Inlet Module
The PSU inlet module is a power-conditioning module. There are three versions of this module; 240VAC,
110VAC and a 48VDC. Both the 240AC and 110VAC inlet modules have an IEC320-C19 socket into which the
provided and respective mains power cord is plugged. The inlet module provides a degree of mains surge
protection.
Although the AC PSU module accommodates an input voltage range from 110V to 240V, the appropriate 110V
or 240V AC inlet module has to be fitted.
3.3.2 PSU Module
The PSU module is designed as modular and removable from the front of the repeater. Preceding the AC PSU
is the appropriate inlet module. Currently, two PSU modules are available, 110VAC/60Hz to 240 VAC/50Hz AC
and a 48VDC version.
To remove the PSU module, unscrew the six front mount screws from the front of the unit as illustrated in
Figure-4.
Figure 4 DSPbR AC PSU

Summary of content (2 pages)