A762 Proximity Locator for GOJO® LTX® Dispenser discover. track. monitor.
Preface 4 Trademarks 4 FCC Compliance 4 CE Compliance 5 Copyright Statement 5 Preface Trademarks RF CodeTM and the RF Code logo are trademarks of RF Code, Inc All other product names are copyright and registered trademarks or trade names of their respective owners. Information in this document is provided solely to enable system and software implementors to use RF Code products.
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications.
Proximity Logic Details The A762 Proximity Locator works in conjunction with A750 Room Locators and R142 Proximity Badge tags. A750 Room Locators are positioned to cover specific areas, such as rooms, closets or entire floors. The IR-enabled R142 tags can report specific location data when it transmits its RF location payload to an RF Code reader. As a person moves from one room to another, their badge tag will transmit the location code it detected from the last seen A750.
Installation and Configuration Figure 2: A762 Antenna Pattern Installation and Configuration To configure the A762 Proximity Locator you will need to use the Proximity Locator Utility which is provided on the CD that came with the A762 Proximity Locator. A USB Type A to micro-B cable (not provided) is needed to connect the A762 Proximity Locator hardware to a Windows platform running the Proximity Locator Utility.
After installing the application from the CD, select Start > All Programs > RF Code > Proximity Locator Utility to launch the application and display the main screen. The A762’s USB cable needs to be plugged into an available USB port on the computer on which the utility software is running. Configuration It is suggested that you use the utility to configure your Proximity Locator before mounting the LTX dispenser to the surface.
he Test Continuously check-box, when selected, will continuously display the latest Tag IDs, Tag RSSI, T Device RSSI and Combined RSSI readings of the tags that are in proximity to the Proximity Locator device. Install the A762 Proximity Locator inside the GOJO LTX Dispenser per GOJO instructions and procedures. Mounting 7. Device Diagnostics: To utilize the diagnostics tool, access the Device > Diagnostic menu option. The diagnostics window will appear.
The A762 unit is approved for use within the ranges set forth below. • Operation: -20 to +70 degrees Celsius • Humidity: 10% to 90% RH non-condensing Standard Warranty Limitations xcept as provided herein, the entire liability of RF Code and its suppliers under this limited warranty will be that RF E Code will use reasonable efforts to repair or replace, without charge, all defective Products returned to RF Code by Customer, all as more particularly described in the End User Warranty.
discover. track. monitor.