of of Re:connect M 203 EIB/ KNX Bridge Dominating Entertainment. Revox of Switzerland.
Re:connect M203 EIB/ KNX Revox EIB Protocol This Operating manual describes the layout and the setting options on the M203 EIB-Bridge pages. The description does not include the Revox EIB Protocol that the EIB programmer must adhere to, so that the M203 EIB-Bridge can recognise the incoming EIB Group addresses and convert them into functions for the Revox Multiroom System.
Re:connect M203 EIB/ KNX Table of Contents Revox EIB Protocol 1 Table of Contents 2 M203 EIB Bridge 3 Installation 3 Connection plan 3 Connections 4 M51 Link IN 4 M51 Link OUT 4 Serial interface RS 232 5 IR-Link 6 Connection example EIB-Part 7 Connection example Revox MR-Part 8 Setup key 9 #1 Slot Selection 9 #2 EIB Address 10 #2 EIB Debugger 11 Released EIB products 12 Overview Revox Multiroom System 13 Technical Data 14 Guarantee 14 Included in delivery 14 2
Re:connect M203 EIB/ KNX M203 EIB-Bridge The M203 EIB-Bridge establishes the bridge between on the one side the Revox Multiroom System and on the other side, the EIB Domestic facility management system. The data exchange occurs between the M203 EIB serial interface and a serial EIB data interface for bus couplers. The M203 EIB-Bridge is only designed to handle communication with an EIB data interface and cannot receive any other protocols.
Re:connect M203 EIB/ KNX Connection: M203 with M51 Connection: M203 with external interfaces Socket: M51 LINK IN Socket: M51 LINK OUT The M203 interface is connected to the M51 LINK IN socket on the back of the M51 with the telephone cable supplied. The M51 LINK OUT can be used to connect additional external interfaces to the M203 interface. These could, for example, be the M201 IR interface, a M200 Domotic interface, a M202 Ethernet interface or simply an additional M203.
Re:connect M203 EIB/ KNX Connection: M203 with serial interface Socket: RS232 Using the RS232 serial interface, the M203 EIB-Bridge can communicate with a serial data interface from an EIB system. If the customer requires it, the keypad units shown for controlling the Revox Multiroom System, are programmed through an EIB tool, e.g. ETS3. The basis for the programming is the EIB protocol, which describes the communication between EIB bus connectors and the M203 EIB-Bridge. Only Type FT 1.
Re:connect M203 EIB/ KNX Connection: M203 with IR controller Socket IR- LINK The maximum number of IR receivers that can be switched in parallel per M203 is 3. Connect the small M204 IR receiver, which is available in four different models, to the IR Link. Now you can locate the M51 in a concealed location or outside the normal range of your remote control, without having to forego any of the convenience of using the remote control.
Re:connect M203 EIB/ KNX Connection example – EIB part 7
Re:connect M203 EIB/ KNX Connection example – Revox MR part The EIB wall-mounted keypad units are installed in the required (additional) rooms, which make up the Revox Multiroom System. Each Additional room amplifier can be addressed over the M203 EIB-Bridge. Additionally, the Additional room amplifier can be integrated into a scene control.
Re:connect M203 EIB/ KNX Setup key Slot Selection Using the Setup key, you can call the M203 menu, which appears in the M51 display. If a second M203 (M200) is connected to the M51 Link output, a different address must be assigned through the slot selection so that both M203s don’t occupy the same slot address. This would cause errors. In the case of a double assignment, neither of the two M203s would be shown in the M51 Version list.
Re:connect M203 EIB/ KNX Setup #2 - EIB Adresse The definition of the middle (Y) and lower (Z) group addresses is handled by the Revox protocol. An individual group address YZ results from each combination of (Multiroom) zone, room and function. The easiest way of calculating the individual YZ group addresses is to use the Excel Configuration guide that can be downloaded from the Revox Homepage, ww.revox.de / Download/ Re:connect.
Re:connect M203 EIB/ KNX Important information Setp #2 – EIB Debugger • Parallel operation The Revox M217 Wallmounted display and/or the M218 wall-mounted control panel can be installed parallel to an EIB Controller. Both controllers have the same priority. The M217 wall-mounted display modifies the address within a zone. There is an information window in the middle of page #2, which gives an overview of the activity on the EIB data interface.
Re:connect M203 EIB/ KNX Approved data interfaces and BCUs The following data interfaces, including BCUs, have been tested and released by Revox: GIRA FT1.2 Serial data interface GIRA Part no.: 0504 xx Suitable BCU: BCU2.1 GIRA Part no.: 0645 xx Merten Combi-interface with integrated BCU2: Merten Part no.: 6816 L Because other EIB products from other companies are also certified, it is theoretically possible to work with them.
Re:connect M203 EIB/ KNX Revox Multiroom System overview The following Operating manuals contain a detailed description of the Revox Multiroom System. • Multiroom Module (MK 1 – 3) • M219 Additional room amp. • M217 Wall-mounted display The overview shows the maximum number of (Additional) rooms in a Revox Multiroom System, if no M217 Wall-mounted display is used and if the room control is done through the EIB system.
Re:connect M203 EIB/ KNX Technical data IR-LINK: + IN - Positive voltage 10-20V (DC) IR signal Ground (GND) Dimensions: 113 x 25 x 50 mm (WxHxD) Weight: 150 g Power consumption: 35 mA (without IR receiver) Max. cable length: 100 m (M203- M51) Max. cable length: 30 m (M203 - IR receiver) E & OE Product subject to technical modifications. Description: Version M203-3 0.70 Guarantee Included in delivery The guarantee period is 24 months from the date of purchase.
Re:connect M203 EIB/ KNX GERMANY Revox GmbH, Am Krebsgraben 15, D-78048 VS-Villingen Telefon +49 7721 8704 0, Fax +49 7721 8704 29 info@revox.de, www.revox.de SCHWEIZ Revox Schweiz AG, Wehntalerstrasse 190, CH-8105 Regensdorf Telefon +41 44 871 66 11, Fax +41 44 871 66 19 info@revox.ch, www.revox.ch Zentralservice Revox GmbH, Am Krebsgraben 15, D-78048 VS-Villingen Telefon +49 7721 8704 43, Fax +49 7721 8704 49 info@revox.de Manual M203 EIB/ KNX Bridge / Part no.: 10.30.