Quick Instruction Guide
SPB411
Revogi Innovation Co.,Ltd.
Smart Meter
Smart meter, based on BLE (Bluetooth 4.0), is kind of smart
product which you can use the smart phone/tablet to control ,e.g.
the on-off status of electrical appliance and check the power
consumption details.
Description
Power meter on work
Power meter off work
Off
On
Meter Indicator
Function
Button
Power Touch Button
LED Status
Work as a physical switch to turn the
smart meter power on /off
Specification
100-120V~ / 60Hz / 15A
37.5X45X24 mm
100-120 V~ / 60Hz / 15A
SPB411
Input:
System required:
Model:
Dimention:
Output:
Weight:50g
Android system :more than 800 x480
resolution, Android 4.3+;
IOS:iOS6+
Installation
Download App
Scan with smart device,Or search “Meterplug” on Google Play and
Apple store.
Plug the smart meter into outlet
Products introduction
Rules
Create Rule
Week
Tap to show the power consumption in the past week.
Tap to show the power consumption in the past 30 days.
Day
Tap to show the power consumption in the past 24 hours.
Month
ON
Tap to turn off the power of Smart Meter.
Tap to turn on power of Smart Meter.
Check the watts of the current device powered by Smart
Meter
OFF
Watts
Energy
Power
Tap" " to add the rule about the working time of the Smart
Meter,up to 5 rule can be added.
Enjoy!
Operate the APP
Operate the app, the smart meter will be automatically paired with
the smart phone/tablet
Functions
Smart Meter interface
Real-time power details for the smart meter.
Graphs of daily, weekly, monthly and yearly power
consumption of the smart meter.
Set specific everyday working time for the smart meter.
Set the countdown to turn off the smart meter.
Device name(can be edited);Hardware Version; RGB
LED (turn on/off the Meter indicator); Proximity switch
(when switched on, the smart meter will be automatically
turned on /off when you approach/leave the smart
meter);, Factory Setting Reset.
Setting
Power
Energy
Rules
Timer
Add new devices
Delete Rule
Slide one certain rule to the left ,tap the "Delete".
Timer
Tap into the timer interface, set the time and start the
countdown.
Settings
Device Name
You can change the name with the device applied likeAC.
Hardware Version
Check the device information of the Smart Meter.
Factory setting reset
Proximity switch
Edit Rule:
Edit the rule about the time you want to turn on and turn off the
smart meter,the day you want to repeat.
One smart phone/tablet can control up to10 smart meters at
the same time, so when other new smart meters are powered
on please tap the" " on the app start interface and "Find
new meter".
When this function start ,the smart meter will automatically
turn on/off as you step into/out the bluetooth coverage.
This will delete all data and reset all settings.
Touch Button
Meter Indicator
Plug the Smart meter into a common power outlet,Open the smart
device Bluetooth.
Communication:
Bluetooth4.0(Bluetooth Low Energy)
FCC Caution:
This device complies with part 15 of the FCC Rules.
Operation is subject to the following two conditions: (1)
This device may not cause harmful interference, and (2)
this device must accept any interference received,
including interference that may cause undesired
operation.
Any Changes or modications not expressly approved by
the party responsible for compliance could void the
user's authority to operate the equipment.
This equipment has been tested and found to comply
with the limits for a Class B digital device, pursuant to
part 15 of the FCC Rules. These limits are designed to
provide reasonable protection against harmful
interference in a residential installation. This equipment
generates uses and can radiate radio frequency energy
and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio
communications. However, there is no guarantee that
interference will not occur in a particular installation. If
this equipment does cause harmful interference to radio
or television reception, which can be determined by
turning the equipment off and on, the user is encouraged
to try to correct the interference by one or more of the
following measures: -Reorient or relocate the receiving
antenna. -Increase the separation between the
equipment and receiver. -Connect the equipment into an
outlet on a circuit different from that to which the receiver
is connected. -Consult the dealer or an experienced
radio/TV technician for help.
IC Caution:
This device complies with Industry Canada’s licence-
exempt RSSs. Operation is subject to the following two
conditions: (1) This device may not cause interference;
and (2) This device must accept any interference,
including interference that may cause undesired
operation of the device. Le présent appareil est
conforme aux CNR d'Industrie Canada applicables aux
appareils radio exempts de licence. L'exploitation est
autorisée aux deux conditions suivantes : (1) l'appareil
ne doit pas produire de brouillage, et (2) l'utilisateur de
l'appareil doit accepter tout brouillage radioélectrique
subi, même si le brouillage est susceptible d'en
compromettre le fonctionnement.

Summary of content (1 pages)