User's Manual

RE118 Interlogix
®
Compatible Trident
Environmental Sensor
Trident is an integrated environmental sensor. It detects water
and reports extreme temperature conditions.
Features
Titanium probes for unmatched corrosion immunity
IP67 rated waterproof enclosure
GORE® vent equalizes enclosure pressure
5 year warranty
Enroll by placing the panel into wireless enrollment mode and
then sending an enrollment signal from the sensor. The ood
signal is enrolled by default. To Enroll the freeze and heat
zones, remove the sensor cover. Use a wire or a paper clip
to short the desired outer terminal to the center terminal,
shorting one terminal at a time.
DL ID Conguration
Flood zone is the serial number shown on the device
Freeze zone is the serial number with last digit
replaced with a 1
Heat zone is the serial number with last digit replace
with a 2.
Install by placing the sensor in the location requiring water or air
temperature detection. If desired, the wall clip can be used to
secure the Trident sensor.
Optional Wall Clip Securing
Remove the Trident body from wall clip.
Secure wall clip to a surface with a #6 mounting
screw.
Example securing locations: wall, baseboard or
Optional Wall Clip Securing
Remove the Trident body from wall clip.
Secure wall clip to a wall with a #6 screw.
Example securing locations are a wall, baseboard
or cupboard.
Detects water pooled under the sensor and reports extreme air
temperature conditions.
Default Temperature Trip Points
Heat alarms when over 100.4° F (38° C)
Heat restores when under 96.8° F (36° C)
Freeze alarms when under 44.6° F (7° C)
Freeze restores when over 48.2° F (9° C)
To replace the battery, insert a at blade screwdriver into the
front slot and twist. To reinstall the cover, align the rear latches
and roll the cover forward until it snaps into place.
I
N
S
T
A
L
L
G
U
I
D
E
I
Mounting Screw Hole
Front slot
Wall Clip
Verify proper enrollment and operation using your control panel’s installation manual.