User's Manual
RE116_GE_Siren_Instructions.doc Page 1 of 4 2/20/2012
www.ResolutionProducts.com
Wireless
Security
Solutions
RE116 Siren, GE
®
-Simon XT Compatible
Features
• Remote Wireless Siren
• For operation with Simon XT
• Responds to wireless alarm signal from panel
• Panel supervises Siren & Siren (optionally) supervises Panel
• Backup power on CR123A battery
• Cover tamper
• Unparalleled wireless range
• Low Battery indication
• 3x4x1.25 inches
Key Instructions
• Requires either Resolution RE920 or RE922 Alarm Communicator Cards, which
send wireless alarm signal.
• Engage Battery by removing pink isolator tab.
Battery “+” faces to right, away from tamper spring.
• Mode 1: Panel supervises Siren & Siren supervises Panel
Set switches
Press ENROLL switch on Simon Communicator board.
Put Panel in Enroll Mode.
Press & Release Siren Tamper to enroll Siren in Panel.
• Alternate Mode 2: Panel supervises Siren & Siren DOES NOT supervise Panel
Set switches
Put Panel in Enroll Mode.
Press & Release Siren Tamper to enroll Siren in Panel.
• Put Siren switches in RUN Mode:
1
2
1
2
1
2
RE116_GE_Siren_Instructions.doc Page 2 of 4 2/20/2012
www.ResolutionProducts.com
Operation
• Alarm
Siren follows panel alarm pattern.
• Supervision
Siren sends supervisory signals to panel IF:
Siren has AC power.
AND (if siren is set to supervise panel…)
Siren has heard signal from panel in previous 60 minutes.
• Tamper
When battery cover is opened.
Tamper Switch
F
unction
Switches
Yellow LED
• ON if AC present.
• Flashes on hearing
from Panel.
R
ed LED
• On if AC Present.
• Flashes short ON
when AC lost.
• Flashes evenly
ON/OFF in Enroll.
Battery “+”
B
attery
isolator tab.
Bemove.