User's Manual

RE101_GE-Compat_DWS_Instructions.doc Page 1 of 3 29-Jun-11
www.ResolutionProducts.com
Wireless
Security
Solutions
RE101 GE-Compatible Standard Door / Window
Features
For sensing things that open or separate.
Magnet and Internal reed switch operation.
2 supplemental hardwire zones.
o GE-compatible version reports 2
nd
zone to 2
nd
ID.
Cover tamper.
Strong, reliable RF signal.
10-15 year battery life on CR123A battery.
Low Battery indication.
Key Instructions
Battery “+” faces towards spring.
No end-of-line resistors on hardwire zones.
Panels assume hardwire zone alarm is state in which contact was enrolled.
Center hardwire terminal is common.
Reed switch and terminal closest to (outer) it are 1
st
ID
Inner terminal is 2
nd
ID.
Enrolling:
1
st
ID: Reed switch and outer terminal zone are enrolled by
tamper switch.
2
nd
ID: Inner terminal zone is enrolled by holding down
tamper while installing battery.
Operation
Magnetic and 1
st
(outer) hardwire zone (1
st
ID)
Alarm, when…
… magnet is pulled away from reed switch.
… contact changes to alarm.
Tamper, when cover is opened.
Supervisories, every hour.
2
nd
(inner) hardwire zone (2
nd
ID)
Alarm: when contact changes to alarm condition.
Tamper: none.
Supervisory: every hour.
RE101_GE-Compat_DWS_Instructions.doc Page 2 of 3 29-Jun-11
www.ResolutionProducts.com
Specifications
Magnet trip distance: 1 inch nominal
Mounting hardware: # 4 or #6 screws
Replacement Battery: CR123A 1550mAH
Temperature Range: 0F to 120F
Housing dimensions: 3.3x1.4x1.1 inches
Specifications subject to change without notice.
Internal Picture
Outer Terminal Zone
Center Common Terminal
Inner Terminal Zone
2
nd
ID
Magnetic Reed Switch
1
st
ID