User Manual

7.1
Symptom Cause Action
Probe fails to power up
(no LEDs illuminated or
fails to indicate current
probe settings).
Exhausted batteries. Change batteries.
Unsuitable batteries. Change batteries.
Batteries inserted incorrectly. Check battery insertion.
Batteries removed for too short a
time and probe has not reset.
Remove batteries for a minimum
of 5 seconds.
Probe fails to switch on.
Exhausted batteries. Change batteries.
Batteries inserted incorrectly. Check battery insertion.
Probe out of range. Check position of RMI or RMI-Q,
see operating envelope.
No RMI or RMI-Q 'start/stop'
signal (radio on mode only).
Check RMI or RMI-Q for green
start LED.
Incorrect spin speed (spin switch
on only).
Check spin speed and duration.
Malfunctioning shank switch
(shank switch mode only).
Check switch operation.
Incorrect switch on method
configured.
Check configuration and alter as
required.
Incorrect multiple probe mode
setting configured.
Check configuration and alter as
required.
RMP60 in hibernation mode
(radio on mode only).
Ensure probe is in range and wait
up to 30 seconds, then resend
switch on signal.
Check position of RMI or RMI-Q,
see operating envelope.
Fault finding
Draft copy 09/07/12

Summary of content (8 pages)