Quick-start guide H-6588-8500-06-A RLP40
EN DE ES FR IT 日本語 Issued: xx.xxxx Publications for this product are available by scanning the barcode or visiting www.renishaw.com/rlp40. Weitere Informationen zu diesem Produkt sind unter folgendem Link www.renishaw.de/rlp40 abrufbar. Las publicaciones para este producto están disponibles a través de www.renishaw.es/rlp40. Les documentations pour ce produit sont disponibles en visitant le site www.renishaw.fr/rlp40. La documentazione per questo prodotto è disponibile visitando il sito www.
PL CS RU 中文 (繁體) 中文 (简体) 한국어 Publikacje dotyczące tego produktu są dostępne w witrynie www.renishaw.pl/rlp40. Dokumentaci k produktu najdete na www.renishaw.cz/rlp40. Документация по данному изделию доступна на сайте www.renishaw.ru/rlp40. 請訪問雷尼紹網站以獲得此產品的的相關文件檔案: www.renishaw.com.tw/rlp40。 请访问雷尼绍网站以获得此产品的相关文档 www.renishaw.com.cn/rlp40。 이 제품의 관련 자료는 www.renishaw.co.kr/rlp40 에서 확인 가능 합니다.
This page is intentionally left blank.
Safety Information to the user The RLP40 is supplied with two non-rechargeable ½AA lithiumthionyl chloride batteries (Please refer to the RLP40 radio machine probe installation guide [Renishaw part no. H-6588-8504]). Lithium batteries must be approved to (BS EN 62133:2013 [IEC 62133:2012]). Once the charge in the batteries is depleted, do not attempt to recharge them.
In all applications involving the use of machine tools, eye protection is recommended. The RLP40 has a glass window. Handle with care if broken to avoid injury. Information to the machine supplier/installer It is the machine supplier’s responsibility to ensure that the user is made aware of any hazards involved during operation, including those mentioned in Renishaw product literature, and to ensure that adequate guards and safety interlocks are provided.
Batteries ½ AA (3.
Fitting the stylus 1 2 1,8 Nm – 2,2 Nm (1.3 lbf.ft – 1.6 lbf.
CAUTION Please remove the battery isolation device from the battery compartment before use. ¬ Take care not to short the battery contacts as this may be a fire hazard. Ensure the contact strips are located securely..
EN Configuring the probe Probe settings can be reviewed and configured by using the Opti Logic technique or Trigger Logic™ technique. The Probe Setup app enables the application of Opti Logic and provides interactive instructions and informative videos to apply Trigger Logic to review and configure settings and to partner the probe.
Configuring the probe with Opti Logic Opti Logic is accessed via the Probe Setup app. For full details about Opti Logic, refer to the Probe Setup app which is available for download on the App Store or Google Play.
Reviewing the probe settings 3 Key to the symbols 2 LED short flash >5s 1 LED long flash LED check Switch-on method Radio on (omitted if “Multiple probe mode” was selected) or Spin on Switch-off method Radio off or Spin off or Short timeout 12 s or Medium timeout 33 s or Trigger filter Level 1 (off) 12 or Level 2 (10 ms) or Level 3 (20 ms) Long timeout 134 s
Hibernation mode setting (RMI-Q using “radio on” only) On 30 s On 5s or or Off Multiple probe mode (RMI-Q only, omitted for “radio on”) (see “Multiple probe mode settings” to view all 16 choices) Mode off Mode on or Machine 1 or Machine 2 Machine 16 Battery status Battery good Battery low or Probe in standby mode (after 5 seconds) 13
Multiple probe mode settings (RMI-Q application only) Multiple probe mode Mode off Mode on or Machine 1 Machine 5 Machine 9 or or or Machine 13 Machine 2 Machine 6 Machine 10 or or or Machine 14 or Machine 3 Machine 7 Machine 11 or or or Machine 15 or Machine 4 Machine 8 Machine 12 Machine 16 or Return to “Mode off” 14
This page is intentionally left blank.
Probe partnering function Using Trigger Logic™ the probe partnering function enables the probe to be partnered with RMI-Q or RMI-QE. 3 2 >5s 1 LED check Key to the symbols LED short flash LED long flash Deflect the stylus for less than 4 seconds to move to the next menu option. To exit, leave the stylus untouched for more than 120 seconds. All probe settings will be shown, ending with “Battery status” being displayed. Partnering successful. Probe is now in standby.
Whilst the “Battery status” is being displayed, deflect and release the stylus to enter “Partnering mode off”. Probe status will flash red to acknowledge this. Battery status Battery good Battery low or At this point turn on either the RMI-Q or RMI-QE.
With RMI-QE switched on After 8 seconds Partnering mode 120 seconds probe in standby if RMI-QE is turned off Partnering mode off RMI-QE Partnering mode Partnering mode off (RMI-QE found) Partnering mode on 120 seconds probe in standby 20 seconds probe in standby If partnering is unsuccessful “Partnering mode off” will be displayed again after 8 seconds. Deflect the stylus for less than 4 seconds to select “Partnering mode on” again.
This page is intentionally left blank.
RLP40 – RMI-Q partnership System set-up can be achieved by using Trigger Logic™. Partnering mode Partnering mode off Switch on the RMI-Q SYSTEM STATUS LED RMI-Q in “Partnering mode” with empty probe location SYSTEM STATUS LED or RMI-Q in “Partnering mode” with full probe location RMI-Q Deflect the stylus to select “Partnering mode on”. Ensure this is done within 60 seconds of the RMI-Q system status LED flashing green.
SYSTEM STATUS LED Partnering pending RMI-Q SYSTEM STATUS LED New RMP partnered SYSTEM STATUS LED or RMP cleared from location Displayed for 5 seconds NOTE: Please refer to the RMI-Q radio machine interface installation guide (Renishaw part no. H-5687-8504) when partnering up to four RMPs. The probe is in standby and the system is ready for use.
RLP40 – RMI-QE partnership System set-up can be achieved by using Trigger Logic™. Partnering mode Partnering mode off Switch on the RMI-Q SYSTEM STATUS LED RMI-Q in “Partnering mode” with empty probe location SYSTEM STATUS LED or RMI-Q in “Partnering mode” with full probe location RMI-Q Deflect the stylus to select “Partnering mode on”. Ensure this is done within 60 seconds of the RMI-Q system status LED flashing green.
SYSTEM STATUS LED Partnering pending RMI-QE SYSTEM STATUS LED New RMP partnered SYSTEM STATUS LED or RMP cleared from location Displayed for 5 seconds The probe is in standby and the system is ready for use. NOTE: Please refer to the RMI-QE radio machine interface installation guide (Renishaw part no. H-6551-8501) when partnering up to four RMPs.
Changing the probe settings (when using with a RMI-Q) Probe settings can be changed using Trigger Logic™. 3 2 >5s LED check 1 Deflect the stylus and hold it deflected until after the battery status has been displayed at the end of the review sequence. Key to the symbols LED short flash LED long flash Deflect the stylus for less than 4 seconds to move to the next menu option. Deflect the stylus for more than 4 seconds to move to the next menu.
Switch-on method Radio on (omitted if “Multiple probe mode” was selected) Spin on Switch-off method Short timeout 12 s Radio off or Spin off Medium timeout 33 s Long timeout 134 s Trigger filter Level 1 (off) Level 2 (10ms) Level 3 (20 ms) 25
Partnering mode Partnering mode on Partnering mode off 120 seconds, probe in standby Partnering successful, 20 seconds probe in standby After 8 seconds Hibernation mode setting (“radio on”only) On 5s On 30 s Off Stop triggering here, unless “Multiple probe mode” is required, in which case deflect the stylus for more than 4 seconds.
Partnering mode Partnering mode off 120 seconds, probe in standby Partnering mode on Partnering successful, 20 seconds probe in standby After 8 seconds Return to “Switch-on method” New settings complete, probe in standby NOTES: If using “Multiple probe mode” , refer to the RMI-Q radio machine interface installation guide (Renishaw part no. H-5687-8504). Further probes require the same “Multiple probe mode” setting, but there is no need to be partnered with the RMI-Q.
Changing the probe settings (when using with a RMI-QE) Probe settings can be changed using Trigger Logic™. 3 2 >5s LED check 1 Key to the symbols Deflect the stylus and hold it deflected until after the battery status has been displayed at the end of the review sequence. LED short flash LED long flash Deflect the stylus for less than 4 seconds to move to the next menu option. Deflect the stylus for more than 4 seconds to move to the next menu.
Switch-on method Spin on Radio on Switch-off method Short timeout 12 s Radio off or Spin off Medium timeout 33 s Long timeout 134 s Trigger filter Level 1 (off) Level 2 (10ms) Level 3 (20 ms) Return to “Switch-on method” NOTE: New settings complete, probe in standby To partner an RLP40 with an RMI-QE see RLP40 – RMI-QE partnership. Once partnering has been successful, the RLP40 will revert to “Partnering mode off”.
Mounting the probe on a shank 1 2 mm A/F ×2 ×2 2 mm A/F ×4 ×4 30
2 ×2 0,5 Nm – 1,5 Nm (0.4 lbf.ft – 1.1 lbf.
Stylus on-centre adjustment 1 < ±20 μm ×4 Y X Z ×4 32
Stylus on-centre adjustment Adjust in Y axis.
3 < ±20 μm ×2 1,5 Nm – 2,2 Nm (1.1 lbf.ft – 1.6 lbf.
Stylus trigger force and adjustment 2 mm A/F +N −N 35
This page is intentionally left blank.
Cleaning Use a clean cloth.
RMI-Q visual diagnostics P1, P2, P3, P4 SYSTEM STATUS LEDs Off Probe number empty Probe number full, in standby KEY TO THE SYMBOLS Continuously on Probe number full, operating Probe number full, 0.
RMI-QE visual diagnostics P1, P2, P3, P4 SYSTEM STATUS LEDs Off Probe number empty Probe number full, in standby KEY TO THE SYMBOLS Continuously on Probe number full, operating Probe number full, 0.
This page is intentionally left blank.
© 2020 Renishaw plc. All rights reserved. Warranty This document may not be copied or reproduced in whole or in part, or transferred to any other media or language, by any means, without the prior written permission of Renishaw plc. Equipment requiring attention under warranty must be returned to your equipment supplier. The publication of material within this document does not imply freedom from the patent rights of Renishaw plc.
EU declaration of conformity C Renishaw plc declares under its sole responsibility that the RLP40 is in conformity with all relevant Union legislation. The full text of the EU declaration of conformity is available at: www.renishaw.com/mtpdoc WEEE directive REACH regulation Information required by Article 33(1) of Regulation (EC) No. 1907/2006 (“REACH”) relating to products containing substances of very high concern (SVHCs) is available at: www.renishaw.
Patents Features of RLP40 and features of similar products are the subject of one or more of the following patents and/ or patent applications: CN CN CN EP EP EP EP EP EP EP EP EP EP EP EP EP 100466003 101287958 101482402 1185838 1373995 1425550 1457786 1477767 1477768 1576560 1701234 1734426 1804020 1931936 1988439 2216761 IN 215787 WO 2004/057552 WO 2007/028964 JP 3967592 JP 4237051 JP 4575781 JP 4754427 JP 4773677 JP 4851488 JP 5238749 JP 5390719 KR 1001244 TW I333052 US US US US US US US US US US 6
雷尼绍(上海)贸易有限公司 • 确保所有安装的电池正负极方向正确。 中国上海市静安区江场三路288号 • 请勿将电池存放在阳光直射或淋雨的地方。 18幢楼1楼 200436 • 请勿将电池加热或弃入火中处置。 • 避免将电池强制放电。 T +86 21 6180 6416 F +86 21 6180 6418 E shanghai@renishaw.com • 请勿使电池短路或强制放电。 • 请勿对电池进行拆解、穿透、施加过度压力,或使其变形。 • 请勿吞咽电池。 www.renishaw.com.
在所有涉及使用机床的应用中,建议采取保护眼睛的措施。 RLP40有一个玻璃窗口。如果玻璃破碎,请务必小心,以免受伤。 机床供应商/安装商须知 机床制造商有责任确保用户了解操作中存在的任何危险,包括雷尼 绍产品说明书中所述的危险,并应确保提供充分的防护装置和安全 联动装置。 在某些情况下,测头信号可能错误指示测头已复位状态。切勿单凭 测头信号来停止机床运动。 设备安装商须知 雷尼绍所有设备的设计均符合相关的EU和FCC监管要求I为使产品 按照这些规定工作,设备安装商有责任保证遵守以下指导原则: • 任何接口的安装位置必须远离任何潜在的电噪声源,如变压器、 伺服系统驱动装置等; • 所有0伏/接地连接都应当连接到机床接地终端上(“接地终端” 是所有设备地线和屏蔽电缆的单点回路)。这一点非常重要,不 遵守此规定会造成接地之间存在电位差; • 所有屏蔽装置都必须按使用说明书中所述进行连接; • 电缆线路不得与电机电源电缆等高电流源并行或靠近高速数据 传输线; • 电缆长度应始终保持最短。 设备操作 如果设备使用方式与制造商要求的方式不符,设备提供的保护功能 可能会减弱。 v
Radio approvals Canada: RLP40QE IC ID: 3928A-RMP40QE RLP40HQE IC ID: 3928A-RMP40QE Japan: This device complies with Industry Canada licence- RLP40QE RLP40HQE exempt RSS standard(s).