EN Publications for this product are available by scanning the barcode or visiting www.renishaw.com/rmp400. DE Für dieses Produkt stehen weitere Informationen zur Verfügung. Scannen Sie dazu den Barcode oder besuchen Sie www.renishaw.de/rmp400. ES Para acceder a las publicaciones sobre este producto escanee el código de barras o visite www.renishaw.es/rmp400. FR IT 日本語 Issued: xx.xxxx Les documentations pour ce produit sont disponibles en scannant le code barres ou en visitant www.renishaw.
PL CS RU 中文 (繁體) 中文 (简体) 한국어 Dostęp do dokumentacji tego produktu można uzyskać, skanując kod kreskowy lub odwiedzając witrynę www.renishaw.pl/rmp400. Publikace pro tento produkt jsou k dispozici po naskenování QR kódu nebo na stránce www.renishaw.cz/rmp400. Если вас интересует информация об этом продукте, отсканируйте штрих-код или посетите сайт www.renishaw.ru/rmp400. 可透過下列方式獲得此產品的出版物 透過掃描條碼,或造訪: www.renishaw.com.tw/rmp400。 可通过以下方式获得此产品的相关文档: 扫描二维码,或访问 www.renishaw.com.
This page is intentionally left blank.
Safety Information to the user The RMP400 is supplied with two non-rechargeable ½AA lithium-thionyl chloride batteries (refer to the RMP400 high accuracy radio machine probe installation guide [Renishaw part no. H-6586‑8500]). Lithium batteries must be approved to (BS EN 62133:2013 [IEC 62133:2012]). Once the charge in the batteries is depleted, do not attempt to recharge them. • Avoid forced discharge of the battery. • Do not short-circuit or force discharge the batteries.
Information to the machine supplier/installer Equipment operation It is the machine supplier’s responsibility to ensure that the user is made aware of any hazards involved during operation, including those mentioned in Renishaw product literature, and to ensure that adequate guards and safety interlocks are provided. If this equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired.
Batteries ½ AA (3.
Fitting the stylus 1 2 1,8 Nm – 2,2 Nm (1.3 lbf.ft – 1.6 lbf.
CAUTION Remove the battery isolation device from the battery compartment before use. ¬ Take care not to short the battery contacts as this may be a fire hazard. Ensure the contact strips are located securely.
EN Configuring the probe Probe settings can be reviewed and configured by using the Opti-Logic™ technique or Trigger Logic™ technique. A Probe Setup app enables the application of Opti-Logic and provides interactive instructions and informative videos to review and configure settings and to partner the probe.
Configuring the probe with Opti-Logic™ Opti-Logic™ is accessed via the Probe Setup app. For full details about Opti-Logic, refer to the Probe Setup app which is available for download on the App Store or Google Play.
Reviewing the probe settings 3 Key to the symbols 2 LED short flash >5s LED long flash 1 × LED check RMI-Q or RMI-QE Switch-on method Radio on (omitted if “Multiple probe mode” was selected) or Spin on Switch-off method Radio off or Spin off 12 or Short timeout 12 s or Medium timeout 33 s or Long timeout 134 s
Trigger filter Level 1 Level 2 or Level 3 or Auto-reset function Auto reset off or Auto reset on Hibernation mode setting (RMI-Q using “Radio on” only) On 30 s On 5s or or Off Multiple probe mode (RMI-Q only, omitted for “Radio on”) (see “Multiple probe mode settings” to view all 16 choices) Mode off Mode on or Machine 1 or Machine 2 Machine 16 Battery status Battery good Battery low or Probe in standby mode (after 5 seconds) 13
Multiple probe mode settings (RMI-Q application only) Multiple probe mode Mode off Mode on or Machine 1 Machine 5 Machine 9 or or or Machine 13 Machine 2 Machine 6 Machine 10 or or or Machine 14 or Machine 3 Machine 7 Machine 11 or or or Machine 15 or Machine 4 Machine 8 Machine 12 Machine 16 or Return to “Mode off” 14
This page is intentionally left blank.
Probe partnering function The probe partnering function enables the probe to be partnered with RMI-Q or RMI-QE. 3 2 >5s 1 LED check × Key to the symbols LED short flash LED long flash Deflect the stylus for less than 4 seconds to move to the next menu option. To exit, leave the stylus untouched for more than 120 seconds. All probe settings will be shown, ending with “Battery status” being displayed. Partnering successful. Probe is now in standby.
Whilst the “Battery status” is being displayed, deflect and release the stylus to enter “Partnering mode off”. Probe status will flash red to acknowledge this. Battery status Battery good Battery low or At this point turn on either the RMI-Q or RMI-QE.
With RMI-QE switched on After 8 seconds Partnering mode 120 seconds probe in standby if RMI-QE is turned off Partnering mode off RMI-QE Partnering mode Partnering mode off (RMI-QE found) Partnering mode on 120 seconds probe in standby 20 seconds probe in standby If partnering is unsuccessful “Partnering mode off” will be displayed again after 8 seconds. Deflect the stylus for less than 4 seconds to select “Partnering mode on” again.
This page is intentionally left blank.
RMP400 – RMI-Q partnership System set-up can be achieved by using Trigger Logic™. Partnering mode Partnering mode off Switch on the RMI-Q SYSTEM STATUS LED RMI-Q in “Partnering mode” with empty probe location SYSTEM STATUS LED or RMI-Q in “Partnering mode” with full probe location RMI-Q Deflect the stylus to select “Partnering mode on”. Ensure this is done within 60 seconds of the RMI-Q system status LED flashing green.
SYSTEM STATUS LED Partnering pending RMI-Q SYSTEM STATUS LED New partner radio probe acquired SYSTEM STATUS LED or Radio probe cleared from location Displayed for 5 seconds NOTE: Refer to the RMI-Q radio machine interface installation guide (Renishaw part no. H-5687-8504) when partnering up to four radio probes. The probe is in standby and the system is ready for use.
RMP400 – RMI-QE partnership System set-up can be achieved by using Trigger Logic™. Partnering mode Partnering mode off Switch on the RMI-QE Partnering mode Partnering mode off (RMI-QE found) SYSTEM STATUS LED SYSTEM STATUS LED or RMI-QE 22 RMI-QE in “Partnering mode” with empty probe location RMI-QE in “Partnering mode”with full probe location Deflect the stylus to select “Partnering mode on”. Ensure this is done within 60 seconds of the RMI-QE status LED flashing green.
SYSTEM STATUS LED Partnering pending RMI-QE SYSTEM STATUS LED New partner radio probe acquired SYSTEM STATUS LED or Radio probe cleared from location Displayed for 5 seconds NOTE: Refer to the RMI-QE radio machine interface installation guide (Renishaw part no. H-6551-8500) when partnering up to four radio probes. The probe is in standby and the system is ready for use.
Changing the probe settings when partnered to a RMI-Q Probe settings can be changed using Trigger Logic™. Key to the symbols LED short flash LED long flash To exit, leave the stylus untouched for more than 120 seconds. Deflect the stylus for less than 4 seconds to move to the next menu option. To exit, leave the stylus untouched for more than 20 seconds. Deflect the stylus for more than 4 seconds to move to the next menu.
Switch-on method Radio on (omitted if “Multiple probe mode” was selected) Spin on Switch-off method Radio off or Spin off Short timeout 12 s Medium timeout 33 s Long timeout 134 s Trigger filter Level 1 Level 2 Level 3 Auto-reset function Auto reset off Auto reset on 25
Partnering mode Partnering mode off 120 seconds, probe in standby Partnering mode on Partnering successful, 20 seconds probe in standby After 8 seconds Hibernation mode setting (“Radio on” only) On 30 s On 5s Off Stop triggering here, unless “Multiple probe mode” is required, in which case deflect the stylus for more than 4 seconds.
Partnering mode Partnering mode off 120 seconds, probe in standby Partnering mode on Partnering successful, 20 seconds probe in standby After 8 seconds Return to “Switch-on method” New settings complete, probe in standby NOTES: If using “Multiple probe mode” , refer to the RMI-Q radio machine interface installation guide (Renishaw part no. H-5687-8504). Further probes require the same “Multiple probe mode” setting, but there is no need to be partnered with the RMI-Q.
Changing the probe settings when partnered to a RMI-QE Probe settings can be changed using Trigger Logic™. Key to the symbols LED short flash LED long flash To exit, leave the stylus untouched for more than 120 seconds. Deflect the stylus for less than 4 seconds to move to the next menu option. To exit, leave the stylus untouched for more than 20 seconds. Deflect the stylus for more than 4 seconds to move to the next menu.
Switch-on method Radio on (omitted if “Multiple probe mode” was selected) Spin on Switch-off method Radio off or Spin off Short timeout 12 s Medium timeout 33 s Long timeout 134 s Trigger filter Level 1 Level 2 Level 3 29
Auto-reset function Auto reset off Auto reset on Return to “Switch-on method” New settings complete, probe in standby NOTE: To partner an RMP400 with an RMI-Q see RMP400 – RMI-Q partnership. Once partnering has been successful, the RMP400 will revert to “Partnering mode off”.
Mounting the probe on a shank 1 ×2 2 mm A/F ×2 2 mm A/F ×4 ×4 31
2 2 mm A/F ×2 0,5 Nm – 1,5 Nm (0.4 lbf.ft – 1.1 lbf.
Stylus on-centre adjustment 1 ×4 360° ±10 µm 33
2 ×2 1,5 Nm – 2,2 Nm (1.1 lbf.ft – 1.6 lbf.
3 ×4 1,5 Nm – 2,2 Nm (1.1 lbf.ft – 1.6 lbf.ft) 360° ±2.
Cleaning Use a clean cloth.
This page is intentionally left blank.
RMI-Q visual diagnostics P1, P2, P3, P4 SYSTEM STATUS LEDs Off Probe number empty Probe number full, in standby KEY TO THE SYMBOLS Continuously on Probe number full, operating Probe number full, 0.
RMI-QE visual diagnostics P1, P2, P3, P4 SYSTEM STATUS LEDs Off Probe number empty Probe number full, in standby KEY TO THE SYMBOLS Continuously on Probe number full, operating LOW BATTERY/START LED Off System error See installation guide Battery is okay and no M-code start/stop in progress Selection error Battery low Partnering complete, probe full M-code start/ stop in progress Flashing Partnering/clearing pending, full SIGNAL LED Partnering pending, empty Off Probe authentication error No p
This page is intentionally left blank.
© 2020 Renishaw plc. All rights reserved. Warranty This document may not be copied or reproduced in whole or in part, or transferred to any other media or language, by any means, without the prior written permission of Renishaw plc. Equipment requiring attention under warranty must be returned to your equipment supplier. The publication of material within this document does not imply freedom from the patent rights of Renishaw plc.
EU declaration of conformity C Renishaw plc declares under its sole responsibility that the RMP400 is in conformity with all relevant Union legislation. The full text of the EU declaration of conformity is available at: www.renishaw.com/mtpdoc WEEE directive REACH regulation Information required by Article 33(1) of Regulation (EC) No. 1907/2006 (“REACH”) relating to products containing substances of very high concern (SVHCs) is available at: www.renishaw.
Patents Features of RMP400 and features of similar products are the subject of one or more of the following patents and/ or patent applications: CN 100416216 CN 100466003 CN 101142461 CN 101171493 CN 101198836 CN 101287958 CN 101476859 CN 101482402 EP 1185838 EP 1373995 EP 1425550 EP 1457786 EP 1477767 EP 1477768 EP 1576560 EP 1613921 EP 1701234 EP 1734426 EP 1804020 EP 1866602 EP 1880163 EP 1893937 EP 1931936 EP 1988439 EP 2154471 EP 2216761 THESE PATENTS ARE APPLICABLE TO THE PREVIOUS MOD LEVEL AND WE
雷尼绍(上海)贸易有限公司 中国上海市静安区江场三路288号 18幢楼1楼 200436 T +86 21 6180 6416 F +86 21 6180 6418 E shanghai@renishaw.com www.renishaw.com.
在所有涉及使用机床的应用中,建议采取保护眼睛的措施。 RMP400有一个玻璃窗口。如果玻璃破碎,请务必小心,以免受 伤。 机床供应商/安装商须知 机床制造商有责任确保用户了解操作中存在的任何危险,包括雷尼 绍产品说明书中所述的危险,并应确保提供充分的防护装置和安全 联动装置。 在某些情况下,测头信号可能错误指示测头已复位状态。切勿单凭 测头信号来停止机床运动。 设备安装商须知 雷尼绍所有设备的设计均符合相关的EU和FCC监管要求I为使产品 按照这些规定工作,设备安装商有责任保证遵守以下指导原则: • 任何接口的安装位置必须远离任何潜在的电噪声源,如变压器、 伺服系统驱动装置等; • 所有0伏/接地连接都应当连接到机床接地终端上(“接地终端” 是所有设备地线和屏蔽电缆的单点回路)。这一点非常重要,不 遵守此规定会造成接地之间存在电位差; • 所有屏蔽装置都必须按使用说明书中所述进行连接; • 电缆线路不得与电机电源电缆等高电流源并行或靠近高速数据 传输线; • 电缆长度应始终保持最短。 设备操作 如果设备使用方式与制造商要求的方式不符,设备提供的保护功能 可能会减弱。 v
Radio approvals Canada: RMP400QE IC ID: 3928A-RMP400QE Japan: RMP400QE 205-200015 This device complies with Industry Canada licenceexempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio exempts de licence.