ZXT-600 AC MASTER INSTALLATION GUIDE
Table of Contents Introduction...........................................................................................2 Product Overview.................................................................................2 Key Descriptions.......................................................................................................... 2 Features...................................................................................................................... 3 Z-Wave Glossary.....................
Introduction ZXT-600, AC Master, is a Z-Wave plus compliant Z-Wave-to-IR Bridge to control split air conditioner by receiving Z-Wave command and translating to Infrared command. With its comprehensive built-In and cloud-stored IR database (library). ZXT-600 can control different brands and models of air conditioners worldwide. ZXT-600 is a security enabled Z-Wave plus device. A security Enabled Z-Wave Plus Controller must be used in order to fully utilize the product.
Features • Working as a Z-Wave thermostat • Support classic inclusion and NWI • Built-in air conditioner IR codes, as well as cloud-based IR code library • IR learning back up • Built-in temperature sensor for room temperature report • Working on battery (2x AA batteries) and/or USB power Z-Wave Glossary Device or Node Devices and nodes are all terms to describe a n i n d i v i d u a l Z- Wa v e d e v i c e . T h e s e a r e a l l interchangeable when setting up your Z-Wave network.
Z-Wave Network A collection of Z-Wave devices is controlled by primary and secondary controllers operating on the same system. A Z-Wave network has its own unique ID code so that controllers not in the network cannot control the system. Primary Controller The first controller is used to set up your devices and network. Only the Primary Controller can be used to include or remove devices from a network.
Get Started • Open the box • ZXT-600 AC Master x 1pc Step 1 Apply Power to ZXT-600 • 2x AA batteries or micro USB • ZXT-600 will detect the first applied power source to decide what Z-Wave device role it will be in after included into the Z-Wave gateway: battery= sleeping device (FLiRS mode). USB power = always awake device (Always Listening mode), refer to Z-Wave Glossary for more information.
Notes: 1. It is recommended to perform the Remove (Exclude) procedure before performing an Add (Include) procedure. 2. Red Indicator flashes TWICE then stay off to represent the Add / Remove process failed, please repeat the above step again. 3. If the Add (Include) process fails, try Remove (Exclude) and /or resetting the AC Master to Factory Default and repeat the above step.
Step Procedure / Description 1 Refer to your primary controller user manual, enter to the browser page that can input the Configuration parameter. Status Indicator 2 I n p u t p a r a m e te r n u m b e r “ 2 7 ” a n d Green Indicator will parameter value (Go to our Website to turn on. If fail, Red Indisearch the corresponding Code Number). cator will flash TWICE. Then complete the Configuration process.
IR Code Learning Step Procedure / Description 1 Refer to your primary controller user manual, enter to the browser page that can input the Configuration parameter Status Indicator 2 Lo o k u p B e l ow m a p p i n g t a b l e fo r learning, and decide the IR setting you intent to learn next. 3 Open the G ateway ’s Configuration Brower page input parameter number “25” and parameter value (according to below Mapping Table), then complete the Configuration process.
Tips • Make sure your Original Remote is in Power OFF Status. • Make sure your Original Remote set FAN Speed to AUTO and FAN SWING to AUTO/ON • Press and Hold the Power Key on Original Remote before AC Master indicate Successful or Not. • Keep away from Incandescent Light or Direct Sunlight during learning. • Make sure IR Transmitter of your Original Remote alight with learning diode of AC Master, you may also slight adjust closer or further away the distance of two devices.
IR Learning Mapping Table (Parameter Number 25) Thermostat Command & IR Setting Parameter Value (Storage Location) Storage in Celsius Unit 6 OFF 2 ON (RESUME) Storage in Fahrenheit Unit 201 17°C COOL 63°F COOL 202 18°C COOL 64°F COOL 203 19°C COOL 66°F or 67°F COOL 204 20°C COOL 68°F or 69°F COOL 70°F or 71°F COOL 205 21°C COOL 206 22°C COOL 72°F or 73°F COOL 207 23°C COOL 74°F or 75°F COOL 208 24°C COOL 76°F COOL 2 25°C COOL 77°F or 78°F COOL 209 26°C COOL 79°F or 80°F C
222 23°C HEAT 74°F or 75°F HEAT 223 24°C HEAT 76°F HEAT 5 25°C HEAT 77°F or 78°F HEAT 224 26°C HEAT 79°F or 80°F HEAT 225 27°C HEAT 81°F or 82°F HEAT 226 28°C HEAT 83°F or 84°F HEAT 227 29°C HEAT 85°F HEAT 228 30°C HEAT 86°F HEAT 3 DRY MODE DRY MODE 1 AUTO MODE 4 FAN MODE 11 AUTO MODE FAN MODE
Important Information • • • • • After all learning completed, User can go back to the ZXT-600 control page on the gateway for normal operation. On the Gateway UI, User can only use the Temperature range from the mapping table, OFF, ON(RESUME), COOL, HEAT, DRY MODE, AUTO MODE and FAN MODE. If User only learnt ON(RESUME), OFF, or part of the settings according to the above table, ZXT-600 will send the learnt data to the Air Conditioner only.
Other Setup Options through Configuration Functions Learn IR code Check IR Code Learning Status (Read Only) Set IR Code number from built-in code library Parameter Number Parameter Value Size ( bytes) 25 (0x19) Default: 0x0000 range: (0x0000 to 0x01B6) refer to learning mapping table 2 26(0x1A) Default: 0x00 range: 0 to 4 (0x00 to 0x04) 0x00 : Idle - IR Channel is idle 0x01 : OK - the last learning operation was completed successfully 0x02 : Learning - ZXT-600 is busy processing previous learnin
Set Builtin IR Emitter Control ( If there have two or more Air Conditioners with the same code set that are used in the same room, user can disable the builtin IR emitter and use the external IR emitter cable to control each air conditioner Control Air Conditioner “SWING” function 32 (0x20) Default: 0xFF 0 or 255 (0x00 or 0xFF) 0x00: Disable 0xFF: Enable (Default) 1 33 (0x21) Default: 0x01 Range 0 to 1 (0x00 or 0x01) 0x00 : Swing OFF 0x01 : Swing Auto (Default) 1 14
Calibrate temperature 37 (0x25) reading Temperature offset value. 0x00 = 0°C (Default) 0x01 = 1°C 0x02 = 2°C 0x03 = 3°C 0x04 = 4°C 0x05 = 5°C 0xFF = -1°C 0xFE = -2°C 0xFD = -3°C 0xFC = -4°C 0xFB = -5°C 1 Set Auto Report Condition 30 (0x1E) Trigger By Room Temperature change 0x00 = Disable AUTO report function (Default) (for saving battery life) Auto report if room temperature is different from last report. 0x01 = 1°F (0.5°C) 0x02 = 2°F (1°C) 0x03 = 3°F (1.5°C) 0x04 = 4°F (2°C) 0x05 = 5°F (2.
Note: All the above Parameter Number and Value is in Hexadecimal Numbering Format, if the Gateway only support decimal numbering format, please change it to decimal value accordingly.
Reset to Factory Default Press and Hold “PROG” button for 3 seconds on AC Master, the Green Indicator will light up. DO NOT Release the “PROG” Button until Green Indicator flashes TWICE. Mounting Required tools and supplies • • • • • • • Phillips Screwdriver Drill Drill bit (3/16” for drywall, 7/32” for plaster) Hammer Pencil Level (optional) AA Alkaline Battery 2pcs (Not Included) or 5VDC 1A Power Adaptor with 1.
Mounting Location Tips The ZXT-600 should be mounted on an inner wall about 5ft (1.5m) above the floor where it is readily affected by changes of the general room temperature with freely circulating air. Before mounting, check the material and structure of the mounting location. If the location does not have the proper material or structure, the ZXT-600 can fall and cause an inquiry. Avoid mounting above or near hot surfaces or equipment (e.g. TV, Heater, Refrigerator).
Technical Specifications Model no. BW8490US (ZXT-600US) BW8490EU (ZXT-600EU) BW8490AU (ZXT-600AU) BW8490JP (ZXT-600JP) BW8490KR (ZXT-600KR) BW8490IN (ZXT-600IN) BW8490CN (ZXT-600CN) RF Frequency 908.4MHz (ZXT-600US) 868.4MHz (ZXT-600EU) 921.4MHz (ZXT-600AU) 922.5MHz (ZXT-600JP) 920.9MHz (ZXT-600KR) 865.2MHz (ZXT-600IN) 868.
WARRANTY ONE-YEAR LIMITED WARRANTY: Remotec warrants this product to be free from defects in materials and workmanship under normal use and service for a period of one year from the original date of purchase from the distributors or dealer.
Regulatory information FCC Compliance Statement This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: • This device may not cause harmful interference, and • This device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules.
IC Notice This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: • This device may not cause interference, and • This device must accept any interference, including interference that may cause undesired operation of the device. Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence.