Introduction
RCS-433CKPD Keypad is a codified radio keyboard operating at 433,92 MHz.
The best use of the product is on applications where a codified radio signal has to be used to control:
gates, garage doors, rolling shutters, sun-blinds, anti-burglar appliances, lightings, etc. The code has a
very high security coding system (19683 code combinations). The radio transmission is enabled only after
the dialing of a security user code. There are up to 6 different channels that can activate up to 6 different
receivers or relays. Compatible receivers: RCS-433DSR2LC, RCS-433BR2.
The internal memory can store up to 24 different security user codes and 1 Master code.
The product fully complies with Part. 15 of FCC Rules.
INSTALLATION
Technical Specifications
Number of keys: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Number of channels: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Supply: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Vdc
Battery duration: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . about 36 months
Battery type: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Lithium CR123A
Current consumption: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 mA
Operating frequency:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 433.92 MHz
Modulation: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . AM/ASK
E.r.p.:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6 mW
Security Code combinations number:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19683
User security code number:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24+1
Transmission duration: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . until press / 2 sec.
Range in open space:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . from 150 to 700 m
Operating temperature: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . from 14 °F to 131 °F
Dimensions:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50.84*60.84*0.6mm
Weight: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 oz
IP Protection Grade:
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IP65
Battery Removal & Replacement
Remove the cover and extract the old battery from the
bottom site of the electronic card with an upward traction.
Insert the new battery on the battery location, respecting
the right polarity.
Installation of Keypad
1 - Locate the best position for the fixing, avoiding metallic surfaces that could decrease the RF emission;
2 - Mark the location of the fixing holes using the bottom of the box as drilling template;
3 - Drill the fixing holes and insert the plugs;
4 - Remove the protection strip from the seal;
5 - Assemble the seal and the bottom;
6 - Fix the bottom with the screws supplied;
7 - Mount the cover on the fixed bottom;
8 - Fix the cover to the bottom with the 2 screws supplied.
NOTES: The keypad uses lithium
battery type CR123A-S-3V. The
removal and the disposal of the
battery must be done before the
disposal of the keypad and
according to the current
Regulations.
ATTENTION: Danger of explosion if
the battery is not replaced in the
correct way!
FCC ID: ____________
This device complies with FCC Rules Part 15
Operation is subject to the following two conditions:
1) This device may not cause harmful interferences;
2) this device must accept interference that may cause
undesired operation.
Password
The keypad has a Master Password factory-set to “11111”.
It is suggested that the Master Password be changed to avoid miss-use of keypad.
The Master Password and the User code can have up to 5 digits. If the chosen code is shorter than 5 digits,
then a “#” must be pressed after the last digit, to complete the number, as indicated below:
_ Example 1 : User code 123 : Digit 1, 2, 3, #.
_ Example 2 : User code 1234 : Digit 1, 2, 3, 4,#.
the master password does not need to be changed to enter programming mode. If the end user would like
to keep the password at the factory default they can, although not recommended.
If at any time the user dials a wrong code there will be a distinct LONG beeeeep to let the user know they
have pressed something wrong and need to start over.
If the user presses the
*
key twice it will clear the keys dialed and the user can start over.
When memorizing the dip-switch setting on the receiver this process learns the keypads' specific security
code/dip-switch setting and not just the user code. After this process is done all the user codes that are in
the keypad will activate the respective relay that the security code/dip-switch setting was learned to.
Memorizing Keypad Dip-Switch Setting on Receiver
1 Press relay (1, 2, 3 or 4) learn button on receiver until LED is lit on receiver.
2 Release receiver button and while the LED is lit on receiver press the user code on keypad and
leave last digit of user code press for 2 sec.
3 Receiver LED will blink to confirm keypad dip-switch setting memorization.
Special Functions
The “
*
key will cancel the last command.
WARNING: “Changes or modifications not expressly
approved by the manufacturer could void the user's
authority to operate the equipment”.
NOTE: You can modify each individual dip-switch setting at a time if desired;
Example 2 – Change dip-switch 2 from “0” to “#”.
STEP 1: Dial the “Master Password”
STEP 2: Press “6”
CHANGE
STEP 3: Dial only “2#”
STEP 4: Press “#” then “6”
Master Password Replacement
1 2 3 4 5 6
Dial the factory Press “8” Dial the new Press “8” Confirm the new Press “8”
default master
(then two beeps
master password master password
(two beeps
password
(11111) to confirm) confirm)
New User Memorization Procedure
1 2 3 4 5 6
Dial the master Press “9” Dial the desired Press “9” Confirm new Press “9”
password
(two beeps
user code user code
(two beeps
confirm entry in confirm
programming mode) programming)
“Beep Beep” “Beep Beep”
“Beep Beep” “Beep Beep”
Single User Cancellation Procedure
1 2 3 4 5 6
Dial the master Press “7” Dial the user code Press “7” Confirm the user Press “7”
password
(two beeps
to be canceled code to be
(two beeps
confirm entry in
canceled
confirm
programming mode) cancellation)
“Beep Beep” “Beep Beep”
All User Cancellation Procedure
1 2 3 4 5 6
Dial the master Press “7” Dial the master Press “7” Confirm the Press “7”
password
(two beeps
password master password
(two beeps
confirm entry in confirm user
programming mode) cancellation)
“Beep Beep” “Beep Beep”
WARNING: All the keypads are sold
with the default security code:
“000000000”
It is highly advised to customize
the code!
Made in China.
GUARANTEE
Warranty period: 12 months from the production date placed inside. In this period if
the keypad has any malfunction due to defective component, it will be repaired or
replaced by the manufacturer. The warranty doesn't cover the plastic box.
The assistance will be performed at the factory in Phoenix, AZ.
1 2345
Dial the master Press “6” Dial the sequence Press “#” Then press “6”
password
(two beeps
of 9 couples of to close
confirm entry in
numbers with
(two beeps confirm
programming mode)
corresponding
correct programming)
symbol
(See Example 1)
“Beep Beep” “Beep Beep”
Security Code Setting/Dip-Switch Setting
WARNING: All user codes will be deleted after this procedure.
Master Password Reset
1 2 3 4 5 6
Dial the factory Press “5” Press the serial # Press “5” Press the Press “5”
master password from the keypad serial # again
(two beeps
(11111) confirm)
“Beep Beep”“Beep Beep”
Example 1 – Dip-switches of a Tx already programmed on the receiver: +, 0, -, +, -, -, +, 0, +.
STEP 1: Dial the “Master Password”
STEP 2: Press “6”
STEP 3: Enter Sequence: “1#
, “20, “3*, “4#, “5*, “6*, “7#, “80, “9#
STEP 4: Press “#” then “6”