EN Digital timer thermosatat iSense Installation and Service Manual 120666-AG
Contents 1 Preface ........................................................................................................4 1.1 2 3 General ..................................................................4 Location of the installation ........................................................................5 2.1 Position of the regulator ......................................5 2.2 Installation and connection .................................6 2.3 Location of the outside sensor ..................
Contents 4.3.10 4.3.11 4.3.12 4.3.13 4.3.14 4.3.15 5 6 Selecting the control strategy .................................................................22 5.1 Six control strategies .........................................22 5.2 Setting the control strategy ...............................23 5.3 Specific settings for weather-compensated control ..................................................................24 5.4 Heating curve - For example ..............................25 Installer settings .
3 030211 - 120666-AG
iSense 1. Preface 1 Preface 1.1 General The Remeha iSense is a timer thermostat with many enhanced functions. The controller is supplied in a OpenTherm and RF variant: 4 iSense OpenTherm. 4 iSense OpenTherm RF(Wireless). With the iBase RF transmitter. This installation and service manual describes all the functions of the iSense.
2. Location of the installation iSense 2 Location of the installation 2.1 Position of the regulator Controller OpenTherm and controller RF The controller is set to room control by default. The controller can be installed on an inside wall or in a boiler, if the boiler is suitable for this. This means that the inside temperature is used to control the central heating. It is therefore best to locate the controller on an internal wall in the room in which you spend the most time, such as the living room.
2. Location of the installation iSense 2.2 Installation and connection Before you can connect the controller, you must first: 4 Adjust the boiler so that it can be connected to a OpenTherm controller. See the installation and service manual for the boiler. 4 Shut down the boiler. To do this, proceed as follows: 1. Open the housing by pulling the front and the base plate apart. T001046-D 2. Attach the base plate to the wall using the screws and plugs supplied.
iSense 2. Location of the installation 4. (Only controller OpenTherm) Place 3 AA batteries in the controller if necessary. These are not supplied. The batteries ensure that the clock keeps running when the boiler is switched off. The batteries also power the backlights of controllers for boilers that do not have OpenTherm Smart Power. If you have a boiler with Smart Power, then the backlight of the controller also works without batteries. (Only controller RF) Insert 3 AA batteries into the controller.
iSense 3. Start-up 3 Start-up 3.1 Fitted control unit 3.1.1.
iSense 3. Start-up 3.1.2. Functions of the keys The controller is menu-controlled, which means it is very simple to operate. It only has three buttons. 4 4 4 A B 4 C 4 T000059-B 3.2 The function of button A and button B depends on the task you are carrying out. The function is shown in the display immediately above the buttons. Button C is a push-turn button. You press it to confirm choices (Such as menu selections).
iSense 3. Start-up You can of course adapt the clock programs to your own requirements.
iSense 4. Setting 4 Setting 4.1 Changing the settings 4.1.1. Defining or modifying a timer program Time MO 7:00 20℃ 20℃ 20℃ 20℃ 20℃ 9:00 15℃ 15℃ TU WE TH FR SA SU 15℃ 15℃ 20℃ 20℃ 11:00 13:00 15℃ 15:00 17:00 19:00 21℃ 21℃ 21℃ 21℃ 21℃ 21:00 21℃ 23:00 15℃ 15℃ 15℃ 15℃ 0:00 15℃ 15℃ 15℃ The timing program automatically controls the room temperature on the basis of set time intervals and can be separately regulated for each day of the week.
4. Setting iSense 4. Go to the time you want to set. Press button C to confirm You can use the Remove button to remove the selected switch time. 5. Use button C to set the time and the corresponding desired temperature. 6. Once you have set all switch times for a particular day, you can copy the settings for that day to other days: - Go to the day. - Press Copy - Use button C to select the day(s) you want to copy the settings to, and press Save 7. Go to the day. Then press button C. 8.
iSense 4. Setting The Night temp setting is also used in combination with the functions Day temperature limit, Night temperature limit ¼ "Specific settings for weather-compensated control", page 24 DHW standby function ¼ "Controlling the tap water temperature", page 18. If the set room temperature is below the value set at Night temp., Then the DHW standby function is switched off by default. ¼ "Controlling the tap water temperature", page 18 4.1.3.
iSense 4.2 4. Setting Operating the controller 4.2.1. Selecting a program You can select one of the following programs via Program in the main display: 4 Clock prog.: The central heating temperature is controlled by the program you have set. 4 Continuous day program: The temperature remains constant at the day temperature you have set. 4 Continuous night program: The temperature remains constant at the night temperature you have set.
iSense 4. Setting 4.2.3. Fireplace mode Once the temperature has reached the desired level in the room where the controller is located, the central heating switches off. This may be inconvenient if you have an open fire. Or if a lot of people are present. Other rooms in the house are also no longer heated in this situation. In order to ensure other rooms are still heated, you can switch on the fireplace mode. You do this via the Program button.
4. Setting iSense 4.3 Changing usage settings 4.3.1. Large information line Small information line Setting the display Set the following via: Menu > Settings > Users > Display 4 Info line small: Select what information should be displayed on the small information line. 4 Info line large: Select what information should be displayed on the large information line. 4 Light time-out: Set how many seconds the backlight should remain on after the last button is touched. T001037-04-C 4.3.2.
iSense 4. Setting Some settings can only be changed in the mode Extended mode. The settings you create remain enabled in the modes Basic mode and Normal mode. 4.3.5. Resetting factory settings You can reset all settings, including the clock program, to the works setting via: Menu > Settings > Users > Reset 4.3.6. Calibration You can adjust the measuring value from the inside and outside sensors via: Menu > Settings > Users > Calibration.
4. Setting iSense Other: You can set the start and end of summer time yourself by indicating the month and the week. The time will change on the Sunday. Manual: The controller does not switch between summer and winter time. The time must be changed manually. 4.3.10. Comfort correction It feels more comfortable when the radiators in the home are hot (Between 50°C and 90°C).The perceived temperature is higher than the real temperature due to the radiant heat.
iSense 4. Setting 4 Both functions are active simultaneously. 4 The T icon is shown in the display when DHW standby is switched off. Time Desired room temperature 07:00 20℃ 09:00 15℃ T 11:00 13:00 15:00 17:00 19:00 21℃ 21:00 23:00 15℃ T 00:00 DHW standby The combi-boiler pre-heats periodically in order to be able to meet the demand for hot tap water quickly.
iSense 4. Setting The maximum temperature that can be set depends on the boiler settings. When setting a clock program, start this an hour before you require the first hot water. This gives the boiler sufficient time to heat up. 4.3.13. Central heating settings You can set a number of specific central heating settings via: Menu > Settings > System > CH system: 4 Pump control: When this option is switched on, the pump switches off when there is no demand for hot water.
4. Setting iSense 4.3.14. Frost protection - System You can use the frost protection system option to protect radiators in frost-sensitive rooms against freezing. For example: The temperature in the home at night does not drop below 19℃, which means the pump does not come on. The radiator in the annexe, which gets colder, runs the risk of freezing. The frost protection system option is automatically switched on if you have an outside sensor.
5. Selecting the control strategy iSense 5 Selecting the control strategy 5.1 Six control strategies The controller can be used as a weather compensator or as a room thermostat (Room control). Six control strategies are available for this. 1 RTC: (Modulating control) Room control The control measures the room temperature in the reference room (the room where the thermostat is located). The required flow temperature based on an intelligent control system is now calculated.
iSense 5. Selecting the control strategy Adjustments are not needed in the room where the controller is located. Any radiator valves present in the reference room must be fully opened. 4 OTC + C-RT: Weather-compensated with comfort function The basis of this control strategy is the same as weathercompensated control. The heating curve must therefore be correctly entered. The heating curve is also shifted on the basis of a room temperature that is calculated (therefore not measured).
iSense 5.3 5. Selecting the control strategy Specific settings for weather-compensated control If you have opted for a weather-compensated control strategy, a number of extra settings are available via: Menu > Settings > System > OTC settings > Heating curve Increased room temperature during the day Desired room temperature of 20ºC during the day Desired room temperature of 15ºC during the night 4 Base outside: Outside temperature base point.
5. Selecting the control strategy 5.4 iSense Heating curve - For example The settings for the heating curve are highly dependent on the design of the central heating system and the home. This means that no clear advice can be given on this matter. Use the tables below as a basic setting if you do not know the design information. The heating curve can be optimised during use. The heating curve also shifts upwards or downwards when the temperature is increased or decreased.
6. Installer settings iSense 6 Installer settings 6.1 Telephone number for service messages and failure signals You can enter a telephone number to be shown if the boiler displays a service message or failure signal. Select: Menu > Settings > Installer > Phone number > Service or Repair No telephone number is shown with the message if no telephone number is entered. 6.2 Service messages on or off You can set whether service messages from the boiler can be shown on the controller.
iSense 6. Installer settings 2. Use Function to select the command that the controller has to perform when ordered to by the external module. - Not used: The digital input is switched off. - Day temp.: The continuous day program is switched on. - Night temp.: The continuous night program is switched on. - Service: A service message is given. - Water pressure: A warning is given on the display if the water pressure is too low. 3.
iSense 6. Installer settings Door contact FUNCTION The temperature switches to continuous night temperature after 3 minutes if the door opens. The controller immediately switches back to its normal program when the door closes. SETTING Connect a door contact to the digital input and set the digital input as follows: 4 Mode: Night temp. 4 Contact: Normal. Closed (When the contact is closed for a closed door).
6. Installer settings 6.5 iSense Boiler Setting You can choose a number of specific boiler settings via: Menu > Settings > Installer > Boiler settings: After setting code 0012, depending on the boiler, parameters can be changed. 4 Parameters: Use the boiler manual, when changing the boiler parameters. 4 Restore param.: Restore the boiler factory default settings, using the dF dU code. 4 Reset service: Reset the next service call when the service maintenance has been carried out.
iSense 7. Messages 7 Messages 7.1 Error messages This is what a fault message or service message looks like: No connection to outside sensor Fault indication Display text Menu Program T000063-04-A Error codes Fault indication Display text Solution F200 No connection to outside sensor F203 Faulty connection to boiler F214 Incorrect room temperature reading c and Z are lit up. No connection to outside sensor. Check the boiler's connection to the outside temperature sensor. c is lit up.
7. Messages Error codes iSense Fault indication Display text Solution The water pressure Current water is too low pressure e and c are lit up. E-Code: Boiler E-Code failure c is lit up. The water pressure in your Top up the water in the central heating system. See central heating system is the installation and service manual for the boiler. too low. Boiler failure: See the installation and service manual for the boiler. Or equipment between the controller and boiler.
iSense Problem 7. Messages Solution It takes a long time for the tap 4 Boiler: It may be that the DHW standby function is switched off. water to get up to temperature. In that case, the symbol T is shown in the display. Control the DHW standby function with the DHW standby setting 4 Tank: It may be that the boiler is being heated up too late. Set the tap water temperature with the Tap water temperature setting.
8. Menu / Technical data iSense 8 Menu / Technical data 8.1 Menu structure For user levels Basic and Normal, some menu items are not visible. The Set boiler menu depends on the options offered by the boiler. Menu options Program Factory setting Clock prog. Clock prog. A Clock prog. B Day temp. 20À Night temp. 15À Frost temp. 6À Holiday prog. Fireplace Settings Users Display Key lock User mode Info line small Time Info line large Act.
iSense 8. Menu / Technical data Menu options Remote input Phone number Service report Service code Settings Installer Boiler settings Factory setting Allow ☑ Disallow ⃞ Service () Repair () Off ☑ On ⃞ Off ☑ On ⃞ Parameters Restore param.
8. Menu / Technical data iSense Menu options Settings DHW Anti-Legionella Standby Factory setting Activate on... ⃞ Off ☑ Continuous off ⃞ Continuous on ⃞ Night temp off ☑ DHW temperature Temperature Settings Time/date ☑ 60℃ Clock prog. ⃞ Europe ☑ Other ⃞ Manual ⃞ Set time Set date Summer time Information 8.
iSense 8. Menu / Technical data Specifications Date: Day - Month - Year. Automatic switching to summer time Programs 2 clock programs with 6 switch points per day Boiler clock program with 6 switch points per day 16 Holiday programs Day, Night, Frost protection, Summer mode, Fireplace mode Control precision Temperature: 0,5 ℃ Programme schedule: 10 minutes Wireless range of controller RF The range of the controller RF in buildings is generally 30 metres.
© Copyright All technical and technological information contained in these technical instructions, as well as any drawings and technical descriptions supplied, remain our property and shall not be multiplied without our prior consent in writing.