Regency Horizon™ HZO42 Outdoor Gas Fireplace www.regency-fire.com Owners & Installation Manual MODELS: HZO42-NG HZO42-LP WARNING: FOR OUTDOOR USE ONLY WARNING: FOR YOUR SAFETY If the information in these instructions are not followed exactly, What to do if you smell gas: a fire or explosion may result causing property damage, Do not try to light any appliance personal injury or loss of life. Do not touch any electrical switch: do not use any phone in your building.
To the New Owner: Congratulations! You are the owner of a state-of-the-art Gas Fireplace by REGENCY®. The Horizon™ HZO42 Outdoor fireplace has been designed to provide you with all the warmth and charm of a fire at the flick of a switch. The Horizon™ HZO42 Outdoor fireplace has been approved by Warnock Hersey/ Intertek for both safety and efficiency. As it also bears our own mark, it promises to provide you with economy, comfort and security for many trouble free years to follow.
TABLE OF CONTENTS SAFETY LABEL OPERATING INSTRUCTIONS Copy of Safety Decal .....................................................4 DIMENSIONS Unit Dimensions ............................................................5 INSTALLATION Important Message ...................................................... 6 Before You Start ............................................................6 General Safety Information............................................6 Installation Checklist .............................
For the State of Massachusetts, installation and repair must be done by a plumber or gas fitter licensed in the Commonwealth of Massachusetts. For the State of Massachusetts, flexible connectors shall not exceed 36 inches in length. For the State of Massachusetts, the appliances individual manual shut-off must be a t-handle type valve. 4 364 NOTE: Regency® units are constantly being improved. Check the label on the unit and if there is a difference, the label on the unit is the correct one.
DIMENSIONS UNIT DIMENSIONS 37 - 13/16” (960mm) 41 - 11/16” (1059mm) 43 - 11/16” (1110mm) 15 - 3/16” (386mm) 39 - ½” (1003mm) 15 - 1/4” (387mm) 35 - 1/4” (895mm) 6 - 3/8” (162mm) 23 - 3/8” (594mm) 32 - 7/16” (824mm) 12 - 3/4” (324mm) 17” (432mm) 5/8” (16mm) 10” (254mm) 13 - 7/16” (341mm) 5 Regency Horizon™ HZO42 Gas Fireplace
INSTALLATION IMPORTANT MESSAGE SAVE THESE INSTRUCTIONS The HZO42 Gas Fireplace must be installed in accordance with these instructions. Carefully read all the instructions in this manual first. Consult the "authority having jurisdiction" to determine the need for a permit prior to starting the installation. It is the responsibility of the installer to ensure this fireplace is installed in compliance with manufacturers instructions and all applicable codes.
INSTALLATION LOCATING YOUR GAS FIREPLACE INSTALLATION CHECKLIST 1) Locate appliance: a) Refer to "LocatingYour Gas fireplace" section b) Clearances to Combustibles (Refer to "Clearances" section) c) Mantel Clearances (Refer to "Combustible Mantel Clearances" section) d) Framing & Finishing Requirements (Refer to "Framing & Finishing" section) 2) Top Facing Support and Side Nailing Strips (Refer to "Unit Assembly Prior to Installation" Section). Note: Must be done before installing unit into place.
INSTALLATION MINIMUM CLEARANCES TO COMBUSTIBLES The clearances listed below are Minimum distances unless otherwise stated: A major cause of fires is failure to maintain required clearances (air space) to combustible materials. It is of the greatest importance that this fireplace be installed only in accordance with these instructions. WARNING Fire hazard is an extreme risk if these clearances (air space) to combustible materials are not adhered to.
INSTALLATION FRAMING DIMENSIONS Framing Dimensions Description A B C D E F I J K Framing Height Framing Width Framing Depth Minimum Height to Combustibles Corner Wall Depth Corner Facing Wall Width Gas Connection Opening Height Gas Connection Height Gas Connection Inset HZO42 32-11/16” (30mm) 42 - 3/16" (1072mm) 14-5/8" (371mm) 34 - 1/4" (870mm) 40 - 7/16" (1027mm) 54 - 3/16" (1376mm) 2" (51mm) 3-7/8 " (98mm) 3/4" (73mm) L Gas Connection Opening Width 3-7/8 " (98mm) sulation is required, due to install
INSTALLATION MANTEL CLEARANCES 26 6 4 2 0 14 12 10 8 Due to the extreme heat this fireplace emits, the mantel clearances are critical. Combustible mantel clearances from top of front facing are shown in the diagram on the right. 12" (305mm) Combustible Material Note: Ensure the paint that is used on the mantel and the facing is "heat resistant" or the paint may discolour.
INSTALLATION FINISHING IMPORTANT FINISHING DETAIL NOTE: Before placing unit into final position - it is important to know the total thickness / height of finished hearth. The base of the fireplace should be level or higher than the finished hearth height.
INSTALLATION HZO42 SYSTEM DATA Max. Supply Pressure 14" WC (3.49 kpa) Min. Supply Pressure 5" WC (1.25 kpa) Manifold Pressure 3.5" WC (0.87 kpa) Orifice Size #29 DMS Maximum Input 44,500 Btu/h (13.04 kW) PILOT ADJUSTMENT Periodically check the pilot flames. Correct flame pattern has two strong blue flames: 1 flowing around the flame sensor and 1 flowing across the burner (it does not have to be touching the burner). Burner Flame Sensor 880 S.I.T.
INSTALLATION UNIT ASSEMBLY PRIOR TO INSTALLATION NAILING STRIPS The 6 Standoffs must be correctly positioned and attached before unit is slid into position. The nailing strips come attached to the unit. There is 1 plate on each side and 1 on the top that can be folded out as required. Secure the top and side nailing strips to the framing. STANDOFF ASSEMBLY The standoffs are shipped in a flat position and must be folded into shape and attached. 1) Remove the standoffs from the fireplace.
INSTALLATION DRAIN INSTALLATION (RECOMMENDED) Although this fireplace is designed to operate outdoors safely, rain and other sources of moisture may enter the hearth area, which will cause water to collect inside the base of the unit. To prevent excessive water collection, the installer must provide a way to drain the water from the base of the unit by building or installing a water collector before positioning the fireplace in its location.
INSTALLATION WALL SWITCH AND BATTERY INSTALLATION (INCLUDED WITH UNIT) The unit comes with low voltage wire and a battery extension wire installed. 1) Run supplied wire to desired location - to a max. of 9 feet. 6) Install supplied 4-AA batteries into the battery holder. Using velcro install battery holder to the backside of the battery compartment door. Connect battery terminal. 2) Install supplied electrical box in desired location.
INSTALLATION WIRING DIAGRAM This heater does not require a 120V A.C. supply for operation. (Do not cut the ground terminal off under any circumstances.) NOTE: 4 AA batteries must be installed in the battery pack to operate the burner switch. Proflame 880 SureFire™ Switch 0.886.001 880 Proflame Valve Standard Main On/Off Switch Standard Wall Switch or Optional Wall Switch Remove the protective coating from the following components before proceeding.
INSTALLATION INNER PANEL INSTALLATION Before installation, panels must be handled and cleaned as per instructions noted below: Stainless Steel Panels • Stainless panels must be inspected for scratches and dimples prior to installation. All claims to be recorded at this time. Claims for damage after installation will not receive consideration. • To protect the finish during installation and handling - cotton gloves MUST be worn at all times while handling the panels (even when removing protective coating).
INSTALLATION GLASS CRYSTAL INSTALLATION IMPORTANT NOTE: Only the supplied approved Glass Crystals and Ceramic Spa / Lava Stones are to be used with these fireplaces. Use of any other type of glass crystals or stones can alter the unit's performance, any damage caused by the use of any unapproved glass or stones will not be covered under warranty. When using Ceramic Spa/ Lava Stones DO NOT cover burner ports or pilot light that lead to pilot flame.
INSTALLATION PEBBLE INSTALLATION Unit Glass Crystals HZ54E / HZ54EPV 6 lbs HZ42 / HZ42E / HZ40E 5 lbs Pebbles 2 packages (6 x bags pebbles) 2 packages (6 x bags pebbles) HZ42ST / HZ42STE / HZ42STEPV 5 lbs 2 package (6 x bags pebbles) HZ30E 2 lbs 1 package (3 x bags pebbles) HZI540EB 4 lbs 1.
INSTALLATION VOLCANIC STONE INSTALLATION Evenly spread the glass crystals and volcanic stones over the burner. Ensure the stones do not overlap too much as this will effect the flame pattern. IMPORTANT NOTE: Only the supplied approved Volcanic Stones are to be used with these fireplaces. Use of any other type of stones can alter the unit's performance, any damage caused by the use of any unapproved glass or stones will not be covered under warranty.
INSTALLATION OPTIONAL LOG SET INSTALLATION Installation of Reflective Panels must be completed before installing the log set. Read the instructions below carefully and refer to the images. If the logs are broken do not use the unit until they are replaced. Broken logs can interfere with pilot operation. Install 3lbs of glass crystal on the burner (follow glass crystal instruction sheet) before installing logs.
INSTALLATION 4) Install log D on the burner as shown below. Orient log D across log E in the same way and in a similar position as depicted in Diagram 5- log D will rest up against the back panel. D E Diagram 5 5) Install log F on the right side of the burner as shown below. Orient log F in the same way and in a similar position as depicted in Diagram 6.
INSTALLATION HEAT DEFLECTOR INSTALLATION 1) Install the heat deflector to the top inside of the firebox with 4 screws as shown below.
INSTALLATION FACEPLATE INSTALLATION Remove the protective coating from the faceplate before installation - see handling instructions in panel install section. 1) 3) To install the faceplate - line up the tabs on the faceplate with the 'C' shaped openings on the left and right sides of the unit. There are 3 slots on each tab so the faceplate to accommodate different finishing materials. For installations where thicker finishing material is used - the optional trim piece may be installed to fill the gap.
INSTALLATION GLASS WIND SHIELD INSTALLATION 1) To install the glass wind shield - slot it into the space between the burner tray cover and the bottom access panel. Burner Tray Cover Glass Wind Shield Bottom Access panel WEATHER COVER INSTALLATION / REMOVAL 1) The unit should be covered when not in use for extended periods of time. The soft fabric cover is made of weather resistant material - to protect the unit from the elements.
INSTALLATION ASSEMBLY INSTRUCTIONS FOR A STEEL STUD FRAMING KIT FOR HZO42 Follow these instructions to construct a steel stud frame for the Outdoor fireplace; Overall dimensions = 60" W x 20" D x 52-1/2" H. **Non-combustible finishing board not supplied with kit. Board may be purchased at your local hardware/building supply store.
INSTALLATION 1) Place top/bottom (A) on the ground - flat side down. Bend the tabs up to a 90° angle. 3) Line up the screw holes of (A) with (B). Secure each (B) with 2 wafer screws (one on each side) as shown below. (A) (B) (A) Bend tabs inward to 90°angle. 4) With all 4 - (B) pieces secured to the bottom with 2 screws (1 on each side) (A) can be placed into position, as shown below. Ensure all tabs on the (A) are bent to 90° and oriented to each (B) as shown in step 2.
INSTALLATION 6) Manoeuvre remaining (B) pieces and position in each corner of the frame - flat side facing out - see 2 diagrams below. 9) Position remaining 2 - (C) pieces offset from center rib as shown below. (C) 10) Position (D) on top of (C) pieces - line up screw holes and secure (D) to (C) with 12 wafer screws. 7) LIne up screw holes on top / bottom (A) with each (B)- secure with 3 wafer screws each on top and bottom - 6 screws in total for each outer (B) (3 top- 3 bottom).
INSTALLATION 12) LIne up screw holes on (E) (header) and (B) (inner vertical support). Secure with 2 wafer screws on each side (4 total) as shown below. This will now be the front of the frame. 14) Line screw holes on 1 (F) (corner brace) with (B) + (A) and secure with 4 wafer screws. as shown below. (A) (B) (F) (E) 15) Repeat step 14 for opposite corner as shown below. 13) On the back side of the frame. Install both (F) pieces (corner brace) on opposite corners.
INSTALLATION REMOTE PROPANE / LP GAS ENCLOSURES INSTALLATION GUIDELINES If the unit is permanently connected to a gas piping system from a remote supply tank, installation must be in accordance with local codes or, in absence of local codes, with the National fuel Gas codes ANSI Z223/1.NFPA 54. • Bottom opening must provide a minimum of 1/2 square inches (3.23 cm²) for each pound of propane/LP contained in the tank (see example below).
OPERATING INSTRUCTIONS OPERATING INSTRUCTIONS 1) Read and understand these instructions before operating this appliance. 2) Check to see that all wiring is correct and enclosed to prevent possible shock. 3) Check to ensure there are no gas leaks. FIRST FIRE The first fire in your fireplace is part of the paint curing process. To ensure that the paint is properly cured, it is recommended that you burn your fireplace for at least four (4) hours the first time you use it .
OPERATING INSTRUCTIONS COPY OF LIGHTING PLATE INSTRUCTIONS The lighting plate is located on the underside of the front access panel in the unit. FOR YOUR SAFETY READ BEFORE LIGHTING This appliance must be installed in accordance with local codes, if any; if none, follow the National Fuel Gas Code, ANSI Z223.1/NFPA 54, or Natural Gas and Propane Installation Codes, CSA B149.1.
MAINTENANCE MAINTENANCE INSTRUCTIONS 1) Always turn off the gas valve and unplug the batteries before cleaning. For relighting, refer to lighting instructions. Keep the burner and control compartment clean by brushing and vacuuming at least once a year. When cleaning the logs, use a soft clean paint brush as the logs are fragile and easily damaged. 2) Clean appliance with a damp cloth (never when unit is hot). Never use an abrasive cleaner. The glass should be cleaned with a gas fireplace glass cleaner.
MAINTENANCE VALVE ASSEMBLY REPLACEMENT 1) Turn the unit off and allow it to cool down to room temperature. 9) Remove the front access panel by lifting up and out. 2) Turn off the gas supply to the unit. 3) Remove trim. 4) Remove the faceplate by lifting it up and off the unit. 10) Remove the burner tray by lifting up and out. 5) Remove the glass wind shield by lifting it up and out- place on a soft surface. 11) Remove left and right screws from the burner legs.
MAINTENANCE 12) Slide the burner to the right and lift up and out of the firebox. BATTERY REPLACEMENT 1) Remove the 2 screws securing the battery compartment. 13) Remove the 5 screws securing the Digital Fireplace Burner Control to the firebox. 2) Lift the battery compartment upwards. 14) Remove the DFBC from the unit - see Digital Fireplace Burner Control Removal in this manual. 3) Install 4 - AA batteries and reverse steps. 15) Remove 6 screws an lift out valve tray.
MAINTENANCE DIGITAL FIREPLACE BURNER CONTROL REMOVAL 1) To access to the Digital firebox burner control box - follow steps 1-11 from the Valve assembly replacement instructions on pages 35,36. 5) Disconnect the yellow ground wire with green diagonal stripe for pilot (CN2). See Diagram 4 below. 2) Disconnect the Black Pilot sensor wire with Red Spade connector from the 'ON' on DFBC (Digital fireplace burner control) box. See Diagram 1 below.
PARTS LIST Part # Description 1) 326-552 Faceplate Assembly 2) 326-009 3) 940-368/P 4) 326-525 326-525 Heat Deflector Wind Shield Burner Assembly NG Burner Assembly LP 5) 904-777 904-434 Orifice # 29 (NG) Orifice # 47 (LP) 6) 326-574/P 326-576/P Valve Assembly NG Valve Assembly LP 7) 326-007/P Front access panel 8) 326-048 Burner Tray Cover MAIN ASSEMBLY 326-028 326-036 326-037/F Pilot Hood Top nailing strip Side nailing strip 948-223 326-940 910-363 Logo Plate Weather Cover Wall switch 91
PARTS LIST BURNER ASSEMBLY Part # 9) Description 326-525 326-525 Part # Description Burner Assembly NG Burner Assembly LP 904-777 904-434 Orifice #29 NG Orifice #47 LP 10) 911-024 911-025 Valve NG SIT 880 Valve LP SIT 880 326-930 Log Set 11) 326-008 Burner Tray Cover 12) 911-006 911-007 Pilot Assembly - NG Pilot Assembly - LP Flame Sensor Igniter 9 12 10 11 38 Regency Horizon™ HZO42 Gas Fireplace
PARTS LIST ACCESSORIES Part # Description 13) 326-907 Reflective Stainless Steel Inner Panels 14) 940-368/P Glass windshield 15) 326-552 Faceplate Brushed Stainless 946-676 946-695 Copper Glass Crystals Garden Stones 13 15 14 39 Regency Horizon™ HZO42 Gas Fireplace
NOTES 40 Regency Horizon™ HZO42 Gas Fireplace
NOTES 41 Regency Horizon™ HZO42 Gas Fireplace
NOTES 42 Regency Horizon™ HZO42 Gas Fireplace
WARRANTY Regency® Fireplace Products are designed with reliability and simplicity in mind. In addition, our internal Quality Assurance Team carefully inspects each unit thoroughly before it leaves our facility. FPI Fireplace Products International Ltd. is pleased to extend this limited warranty to the original purchaser of a Regency® Product. This warranty is not transferable.
Register your Regency® warranty online www.regency-fire.com Reasons to register your product online today! • View and modify a list of all your registered products. • Request automatic email notification of new product updates. • Stay informed about the current promotions, events, and special offers on related products.