I1200S Wood Insert www.regency-fire.com Owners & Installation Manual Tested by: Installer: Please complete the details on the back cover and leave this manual with the homeowner. Homeowner: Please keep these instructions for future reference. 918-665a FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St.
Thank-you for purchasing a REGENCY FIREPLACE PRODUCT. The pride of workmanship that goes into each of our products will give you years of trouble-free enjoyment. Should you have any questions about your product that are not covered in this manual, please contact the REGENCY DEALER in your area. Keep those REGENCY FIRES burning. SAFETY NOTE: If this Insert is not properly installed, a house fire may result.
TABLE OF CONTENTS SAFETY LABEL OPERATING INSTRUCTIONS Safety Label ..................................................................4 First Fire ......................................................................16 Fan Operation .............................................................17 Ash Disposal ...............................................................17 Some Safety Guidelines ..............................................17 UNIT DIMENSIONS With Standard Flue Adaptor ................
632-3198 (SEPT.1993) A) B) C D) 15in / 380mm 20in / 510mm 14in / 355 mm 7.375in / 185mm INSTALL ONLY ON A NON-COMBUSTIBLE HEARTH RAISED (F) 1.5IN / 38MM ABOVE AN ADJACENT COMBUSTIBLE FLOOR. COMBUSTIBLE FLOOR MUST BE PROTECTED BY NON-COMBUSTIBLE MATERIAL EXTENDING (E) 16 IN / 405MM TO FRONT AND (G) 8IN / 205MM TO SIDES FROM FUEL DOOR.
UNIT DIMENSIONS WITH STANDARD FLUE ADAPTOR 6" (152mm) Diameter STANDARD FLUE ADAPTOR (171-932) I1200 Regency Wood Insert 5
UNIT DIMENSIONS WITH OFFSET FLUE ADAPTOR 6" (152mm) Diameter OFFSET FLUE ADAPTOR (171-936) 6 I1200 Regency Wood Insert
INSTALLATION Regency Inserts are constructed with the highest quality materials and assembled under strict quality control procedures that ensure years of trouble free and reliable performance. CHIMNEY SPECIFICATIONS It is important that you read this manual thoroughly and fully understand the installation and operating procedures. Failure to follow instructions may result in property damage, bodily injury or even death.
INSTALLATION MASONRY AND FACTORY BUILT FIREPLACE CLEARANCES The minimum required clearances to combustible materials when installed into a masonry or factory built fireplace are listed below. Unit I1200S Adjacent Side Wall (to Side) A 15" (381mm) Mantle** (to Top) B 20" (508mm) Top Facing (to Top) C Side Facing (to Side) D Minimum Hearth Extension* E Minimum Hearth Thickness* F Minimum Hearth Side Extension G 14" (356mm) 7.375"(187mm) 16" (406mm) 1.
INSTALLATION INSTALLING YOUR INSERT SAFETY NOTE: The insert is very heavy and will require two or three people to move it into position. The insert can be made a little lighter by removing the cast iron door by opening it and lifting it off its hinges. Be sure to protect your hearth extension with a heavy blanket or carpet scrap during the installation. 3) Install the unit by first setting the rear of the unit into the fireplace. See diagram 3.
INSTALLATION INSTALLATION INTO A MASONRY FIREPLACE When referencing installation or connection to masonry fireplaces or chimneys, the masonry construction must or shall be code complying. The insert must be installed as per the requirements of your local inspection authority. Three methods of flue connection are acceptable in most areas, these include: 1) Positive flue connection, where a large blocking plate and a short connector pipe is used.
INSTALLATION FACEPLATE, TRIM & OPTIONAL BOTTOM FACEPLATE & FAN SUPPORT INSTALLATION Regular/Oversize Faceplate Installation: 1) Thread the black 1/4" x 3/4" long hex bolts into the faceplate mounting bracket as shown in Diagram 1, leaving them approximately 1/4" out. 2) Fasten the faceplate mounting bracket to the side of the insert using 2 bolts for the top and bottom, see Diagram 1. Repeat for other side.
INSTALLATION Regular/Oversize Faceplate Trim Installation: (Black Trim included with Regular/Oversize Faceplate or Optional Brass Trim) 8) Measure the total height of the faceplate assembly and cut both the left and right side trim accordingly using a metal cutting blade. 9) Assemble the left and right side trim to the top trim using the trim clips provided as shown in Diagram 5. 12) Mount the completed faceplate / trim assembly to the insert.
INSTALLATION 15) Cut the bottom edge of the fan support (using a metal cutting blade) to the length measured in step 14. 18) Secure the fan support to the fan assembly using 4 self tapping screws. See Diagram 9. 16) Remove the fan assembly from the ash lip of the insert and position the fan support to the bottom of the fan assembly. 19) Re-attach the fan/fan support assembly to the ash lip of the insert.
INSTALLATION FAN / BLOWER Your fan should only be installed once the unit is in place in order to prevent any damage to the fan. 1) Align the fan support with the offset clip on the bottom of the ashlip. 2) Slide the supports into the clips. The tension holding the clips in place may be adjusted by increasing or decreasing the offset spacing of the clips. Do not turn fan ON until your insert has reached operating temperature or at least 30 minutes after starting fire.
INSTALLATION FIREBRICK ASSEMBLY Firebrick is included to extend the life of your insert and radiate heat more evenly. Check to see that all firebricks are in their correct positions and have not become misaligned during shipping. DOOR HANDLE Attach spring handle by rotating counter clockwise onto rod. Ensure that the rod fits into the entire length of the spring handle.
INSTALLATION SCREEN DOOR FIRST FIRE Hook screen to the inside on the right side of the firebox door opening. Lock in place by turning handle. When your installation is completed and inspected, you are ready for your first fire. 1) Open draft control fully. 2) Open firebox door and build a small fire using paper and dry kindling, wait a few minutes for a good updraft in the flue to establish the fire. Leaving the door slightly open will help your fire start more rapidly.
OPERATING INSTRUCTIONS FAN OPERATION The fan is to be operated only with the draft control rod pulled out at least 1/2" from the fully closed position. The fan is not to be operated when the draft control rod is in the closed position (pushed in). The fully closed position is the low burn setting. The fan must not be turned on until a fire has been burning for at least 30 minutes.
MAINTENANCE 3) Only burn seasoned wood! Avoid burning wet or green wood. Seasoned wood has been dried at least one year. DOOR LATCH ADJUSTMENT 4) A small hot fire is preferable to a large smouldering one that can deposit creosote within the system. The door latch may require adjustment as the door gasket material compresses over time. Removal of the spacer washer, shown in the diagram below, will allow the latch to be moved closer to the door frame, causing a tighter seal.
PARTS LIST MAIN ASSEMBLY Part # Description 850-141 850-142 850-143 850-144 Black Door - Complete Gold Door - Complete Nickel Accent Door - Complete Gold Accent Door - Complete 2) 4) 5) 6) 8) 9) 16) 17) 19) 20) 846-302 936-243 846-920 * 948-170/P 846-973 846-570 846-918 948-101 948-102 Glass - Replacement 7/8" Adhesive Tape Gasket Glass Retainer Clips (set of 8) Screws - 1/4-20 x 3/8" Glass Retainer Door Handle Assembly Med.
PARTS LIST FACEPLATES 20 Part # Description 171-920 171-924 Faceplate & Trim Set - Regular - Black Trim Set - Regular Brass 171-922 171-926 Faceplate & Trim Set - Oversize - Black Trim Set - Oversize Brass 171-928 Bottom Piece and Fan Support - Regular 171-930 Bottom Piece and Fan Support - Oversize 60) * 61) * 62) * Faceplate Right Side Regular / Oversize Faceplate Left Side Regular / Oversize Faceplate Top Regular / Oversize 64) * 65) * Bottom 1 Piece Faceplate Fan Support *Not available a
PARTS LIST FIREBRICK 70) 76) 81) 84) 85) Part # Description 170-960 Complete Brick Set * * * * * Brick Regular Full Size: 1-1/4" x 4-1/2" x 9" Brick Partial: 1-1/4" x 2" x 9" Brick Partial: 1-1/4" x 1-1/4" x 9" Brick Partial: 1-1/4" x 4-1/2" x 8" Brick Partial: 1-1/4" x 4-1/4" x 8" *Not available as a replacement part.
NOTES 22 I1200 Regency Wood Insert
WARRANTY Regency Fireplace Products are designed with reliability and simplicity in mind. In addition, our internal Quality Assurance Team carefully inspects each unit thoroughly before it leaves our door. FPI Fireplace Products International Ltd. is pleased to extend this limited lifetime warranty to the original purchaser of a Regency Product. This warranty is not transferable.
Regency fireplace products are designed with reliability and simplicity in mind. In addition, our internal Quality Assurance Team carefully inspects each unit thoroughly before it leaves our door. Fireplace Products International Ltd. is pleased to extend this Limited Lifetime Warranty to the original purchaser of a Regency Product. See the inside back cover for details. Register your Regency online at http://www.regency-fire.