Manual Owners & Installation LISTINGS AND CODE APPROVALS These gas appliances have been tested in accordance with AG 103, NZS 5262 and have been certified by the Australian Gas Association for installation and operation as described in these Installation and Operating Instructions. Your unit should be serviced annually by an authorised service person.
To the New Owner: Congratulations! You are the owner of a state-of-the-art Masport Rear Flued Room Sealed Freestanding Gas Fire. The Masport Gas Series of hand crafted appliances has been designed to provide you with all the warmth and charm of a woodfire, at the flick of a switch. The models F37-NG, and F37-LPG of this series has been approved by AGA for both safety and efficiency.
TABLE OF CONTENTS Page Specifications diagram ................................................ 2 Data Plate ................................................................... 4 Installation Specifications ............................................................. 5 Before You Start ......................................................... 5 General Safety Information .......................................... 5 Installation Checklist ...................................................
DATA PLATE This is a copy of the label that accompanies each MASPORT Rear Flued Room Sealed Freestanding Gas Fire. We have printed a copy of the contents here for your review. The data plate is located on the inside of the drop down pedestal door. NOTE: Masport units are constantly being improved. Check the label on the unit and if there is a difference, the label on the unit is the correct one.
INSTALLATION IMPORTANT: SAVE THESE INSTRUCTIONS The MASPORT Rear Flued Room Sealed Freestanding Gas Fire must be installed in accordance AG601 and NZS 5261 and with these instructions. Carefully read all the instructions in this manual first. Consult the building authority having jurisdiction to determine the need for a permit prior to starting the installation.
INSTALLATION LOCATING YOUR MASPORT GAS FIRE 14) Under no circumstances should any solid fuels (wood, paper, cardboard, coal, etc.) be used in this appliance. 15) The appliance area must be kept clear and free of combustible materials, (gases and other flammable vapours and liquids). INSTALLATION CHECKLIST 1) Check Clearances to Combustibles (page 6), location of unit (page 6) and fluing requirements (pages 6-9). 2) Install fluing: Check all fluing requirements, pages 8-10.
INSTALLATION EXTERIOR FLUE TERMINATION LOCATIONS Minimum clearances required for balanced flue terminals or the flue terminals of outdoor appliances according to AG 601 (AGA gas installation code) or NZS 5261 (New Zealand). For vertical termination heights refer to AG 601 or NZS 5261.
INSTALLATION FLUEING The Horizontal Termination Kit includes everything required for a straight through the wall installation, or add a 45o elbow for a corner installation. IMPORTANT Read all instructions carefully before starting the installation. Failure to follow these instructions may create a fire or other safety hazard, and will void the warranty. Be sure to check the fluing and clearance to combustible requirements on pages 6 to 9. Consult your local building codes before beginning installation.
INSTALLATION FLUEING ARRANGEMENTS - VERTICAL TERMINATIONS FOR BOTH RESIDENTIAL & MANUFACTURED HOMES/MOBILE HOMES Offset to Vertical Terminations Vertical Terminations The shaded areas in the two diagrams below show all allowable combinations of straight vertical and offset to vertical runs with vertical terminations. Maximum one 90o elbow. All vertical and offset to vertical flue installations require Flue Restrictor to be set to 32mm open. If the flue is ENCLOSED in a chase (min.
INSTALLATION GAS CONNECTION HORIZONTAL INSTALLATIONS Refer to instructions with Masport DV Rear Exit Flue Kit. 1) Set the unit in its desired location. Check to determine if wall studs are in the way when the fluing system is attached. If this is the case, you may want to adjust the location of the unit. 2) Assemble the desired combination of pipe and elbow to the appliance adapter with pipe seams oriented down.
INSTALLATION Conversion Kit from NG to LPG THIS CONVERSION MUST BE DONE BY AN AUTHORIZED GAS FITTER IF IN DOUBT DO NOT DO THIS CONVERSION !! Conversion Kit # 680-969 Contains: Qty. Part # 1 910-018 1 1 1 1 1 910-037 904-390 908-528 908-255 918-031 Description SIT Conversion Kit50% Turndown LPG LPG Injector (Pilot Orifice) Burner Orifice #52 Red "LPG" label Label "Converted to LPG" Instruction Sheet 7) Unscrew the pilot orifice with the allen key and replace with the LPG pilot orifice in the kit.
INSTALLATION AERATION ADJUSTMENT LOG SET INSTALLATION The burner aeration is factory set but may need adjusting due to either the local gas supply, air supply or altitude. Read the instructions below carefully and refer to the diagrams. If logs are broken do not use the unit until they are replaced. Broken logs can interfere with the pilot operation. NG: LPG: 10mm open 10mm open 3) Place Rear Log A)02-65 on the two pins on the rear log support.
INSTALLATION 7) Place the Left Top Log D)02-46 on the pin on Log B)02-56 and on top of the cutout on Log A)02-65. 11) Position notch in Front Right Log G)02-48 on Log F)02-47 and push the bottom right edge against the bracket on the burner tray. DOOR INSTALLATION (Packaged Separately) 1) Open the two side panels. G)02-48 A)02-65 A)02-65 -47 D)02-46 C)02-44 Cutout Pin E)02-45 F)02 B)02-56 3) Close the door. The latch plate must be centered around the alignment pin. See diaDiagram 1 gram 2.
INSTALLATION PRESSURE TESTING Valve Description The manifold pressure is controlled by a regulator built into the gas control, and should be checked at the pressure test point.
INSTALLATION OPTIONAL REMOTE CONTROL Use the Masport Remote Control Kit approved for this unit. Use of other systems may void your warranty. The remote control kit comes with a hand held transmitter, a receiver and a wall mounting plate. 1) Choose a convenient location on the wall to install the receiver and the receptacle box (protection from extreme heat is very important). Run wires from the fireplace to that location, use Thermostat Wire Table. 2) Connect the wires as per the wiring diagram above.
OPERATING INSTRUCTIONS OPERATING INSTRUCTIONS 1) Read and understand these instructions before operating this appliance. 2) Check to see that all wiring is correct and enclosed to prevent possible shock. 3) Check to ensure there are no gas leaks. 4) Make sure the glass in the door frame is properly positioned. Never operate the appliance with the glass removed. 5) Verify that the fluing and cap are unobstructed. 6) Verify log placement.
OPERATING INSTRUCTIONS COPY OF THE LIGHTING PLATE INSTRUCTIONS FOR YOUR SAFETY READ BEFORE LIGHTING This appliance must be installed in accordance with local codes, if any; if not, follow the current CAN1-B149/ANSI Z 223.1 (Australia: AG601, New Zealand: NZS 5261) WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
MAINTENANCE MAINTENANCE INSTRUCTIONS TROL SYSTEM AND ANY GAS CONTROL WHICH HAS BEEN UNDER WATER. 1) Always turn off the valve before cleaning. For relighting, refer to lighting instructions. Keep the burner and control compartment clean by brushing and vacuuming at least once a year. When cleaning the logs, use a soft clean paint brush as the logs are fragile and easily damaged. CAUTION: ANY SAFETY SCREEN OR GUARD REMOVED FOR SERVICING AN APPLIANCE MUST BE REPLACED PRIOR TO OPERATING THE APPLIANCE.
MAINTENANCE LATCH ADJUSTMENT PANEL DOOR The door latch may require adjustment as the door gasket material compresses after a few fires and after glass replacement. Turn the handle on the adjustable catch to tighten or loosen the latch. 1) Remove the door from the unit and place on a soft surface to prevent scratching. 2) Pull out the door gasket. 3) Remove the nuts holding the glass retainers in place. 4) Remove the glass retainers (sides, top and bottom) and the door catch plate. 5) Replace the glass.
MAINTENANCE FAN MAINTENANCE 3) Unclip the black and white wires from the fan motor. If your fan requires maintenance or replacement it must be performed by an authorised person. Access to the fan is through the plate on the rear wall of the firebox. NOTE: the unit MUST NOT be operated without the fan access panel securely in place and correctly sealed. 4) Lift fan off of the 2 pins, tip back and pull through the opening.
MAINTENANCE 4) Remove the two outside frame pieces by removing two screws per side. See diagram below. 9) Carefully lift the burner tray assembly out. Be careful not to tear gaskets when lifting out the valve tray; these gaskets seal the valve from the exterior of the firebox. FIREBOX PAINT The interior of the firebox is subject to extremely high flame temperatures. While the painted surface is designed for high durability, the combustion conditions can cause deterioration of the paint finish.
PARTS LIST F37 MAIN ASSEMBLY Part#: Aust.
PARTS LIST F37 BURNER & LOG ASSEMBLY Part#: Aust. New Zealand 54) 55) 56) 57) 60) 66) 67) 68) 71) Description 910-373 588412 Knob - Pilot Valve Extension 910-372 588413 Flame Adjusting Knob 918-088 Decal - Control Panel * Switch Plate 680-574/P 680-576/P 910-378 588394 904-240 560259 936-170 556174 910-074 910-038 910-039 * W840470 730-528 904-390 551859 75) 730-935 78) 730-550 Valve Assembly - NG Valve Assembly - LPG Valve - S.I.T.
PARTS LIST F37 DOOR ASSEMBLIES Part#: Aust. New Zealand 101) 105) 106) 107) 108) 111) 112) 208) Description 730-924 Gold Mitred Door - Complete 730-926 Black Mitred Door - Complete 730-932 Gold Wrap Door - Complete 730-928 Gold Panel Door - Complete 650-920 560018 Door Gasket Kit * Ceramic Paper 940-323/P Side Glass 936-243 560087 Glass Gasket 940-322/P Centre Glass * Door Frame Fibre Paper 750-015 Door Glass Extrusion 940-325/P Wrap Glass *Not available as a replacement part.
NOTES _____________________________________________________________________________________ ____________________________________________________________ __________________________________________________________ ____________________________________________________________ _______________________________________________________ _____________________________________________________ __________________________________________________________ _________________________________________________________ ____________
NOTES _____________________________________________________________________________________ ____________________________________________________________ __________________________________________________________ ____________________________________________________________ _______________________________________________________ _____________________________________________________ __________________________________________________________ _________________________________________________________ ____________
WARRANTY THE MASPORT EXPRESS WARRANTY All new Masport Gas appliances are warranted, subject to the following conditions, to be free from defects in material or workmanship under normal use. The Express Warranty on all parts, including firebox components is two years from date of original purchase as well as labour costs involved in the repair or replacement.