Owners & Installation Manual Freestanding Gas Stove LISTINGS AND CODE APPROVALS These gas appliances have been tested in accordance with AS4553-2000, NZS 5262 and have been certified by the Australian Gas Association for installation and operation as described in these Installation and Operating Instructions. Your unit should be serviced annually by an authorised service person.
To the New Owner: Congratulations! You are the owner of a state-of-the-art Regency® Rear Flued Room Sealed Freestanding Gas Stove by FPI Fireplace Products International. The Regency® Gas Series of hand crafted appliances has been designed to provide you with all the warmth and charm of a woodstove, at the flick of a switch. The models F37-NG, and F37LPG of this series has been approved by AHD for both safety and efficiency.
TABLE OF CONTENTS DATA BADGE OPERATING INSTRUCTIONS Data Badge ..................................................................4 Operating Instructions .................................................18 Lighting Procedure ......................................................18 Shutdown Procedure ...................................................18 First Fire ......................................................................18 Convection Fan Operation...........................................
DATA BADGE This is a copy of the label that accompanies each REGENCY Rear Flued Room Sealed Freestanding Gas Stove. We have printed a DO NO T DO NO T DO NO T DO NO T DO NO T DO NO T DO NO T copy of the contents here for your review. The data plate is located on the inside of the drop down pedestal door. NOTE: Regency® units are constantly being improved. Check the label on the unit and if there is a difference, the label on the unit is the correct one.
INSTALLATION IMPORTANT SAVE THESE INSTRUCTIONS The REGENCY Rear Flued Room Sealed Freestanding Gas Stove must be installed in accordance AG601 and NZS 5261 and with these instructions. Carefully read all the instructions in this manual first. Consult the building authority having jurisdiction to determine the need for a permit prior to starting the installation.
INSTALLATION Make it a practice to have all of your gas appliances checked annually. 13) Do not slam shut or strike the glass door. 14) Under no circumstances should any solid fuels (wood, paper, cardboard, coal, etc.) be used in this appliance. 15) The appliance area must be kept clear and free of combustible materials, (gases and other flammable vapours and liquids). INSTALLATION CHECKLIST 1) Locate your gas stove. Refer to the following sections where applicable: a. Clearances to Combustibles b.
INSTALLATION EXTERIOR FLUE TERMINATION LOCATIONS Minimum clearances required for balanced flue terminals or the flue terminals of outdoor appliances according to AS5601-2004 (AGA gas installation code) or NZS 5261 (New Zealand) Minimum Clearance (mm) a b c d e f g h j k Below eaves, balconies or other projections: - Appliances up to 50 MJ/h input 300 - Appliances over 50 MJ/h input 500 From the ground or above a balcony 300 From a return wall or external corner 500 From a gas meter (M) 1000 From an elect
INSTALLATION FLUEING The Regency® Room Sealed System (Horizontal Termination Kit (946-112) and the Vertical Termination with the Co-linear Flex System in combination with the REGENCY Room SealedRear Freestanding Gas Stoves (F37-NG and F37-LPG) have been approved and listed as Room Sealed heater systems by Australian Gas Association. The Horiz. Termination Kit (946-112) includes everything required for a straight through the wall installation, or add a 45o elbow for a corner installation.
INSTALLATION FLUEING ARRANGEMENTS - VERTICAL TERMINATIONS for both Residential & Manufactured Homes/Mobile Homes Vertical Terminations with Co-linear Flex System Vertical Terminations using Dura-Vent Flueing System The shaded area in the diagram shows the allowable vertical terminations installed in a masonry chimney. All vertical flue installations require the Flue Restrictor to be set to 32mm open. All Vertical Flue Terminals must be Simpson Dura Vent (Abey Australia) DV 980 MAS (Australian Modified.
INSTALLATION RESIDENTIAL AND MANUFACTURED HOMES / MOBILE HOMES INSTALLATIONS You will require the following components with your new Regency® Rear Flued Room Sealed Freestanding Gas Stove. Please review your product to make sure you have everything you need. In the event that you are missing any part, contact your dealer. Note: These are the minimum pieces required. Other parts may be required for your particular installation.
INSTALLATION NOTE: For Snorkel terminations in ABOVE grade installations, follow national or local code requirements. 7) Install the Backing Plate into the wall penetration heat shield and attach using 4 screws. Diagram 4. Below Grade Snorkel Installation If the Snorkel Termination must be installed below grade, i.e. basement application, proper drainage must be provided to prevent water from entering the Snorkel Termination. Refer to Dura-Vent Installation instructions for details..
INSTALLATION VERTICAL TERMINATION WITH CO-LINEAR FLEX SYSTEM GAS CONNECTION THE APPLIANCE MUST NOT BE CONNECTED TO A CHIMNEY FLUE SERVING A SEPARATE SOLID FUEL BURNING APPLIANCE. This appliance is designed to be attached to two 3" (76mm) co-linear aluminium flex running the full length of the chimney. See the Flueing Arrangements chart in the "Flue Arrangement" section for minimum and maximum flue lengths. See chart below for minimum distances from roof. Periodically check that the flue is unrestricted.
INSTALLATION CONVERSION KIT #731-968 FROM NG TO LPG USING SIT 820 NOVA GAS VALVE THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER IF IN DOUBT DO NOT DO THIS CONVERSION !! Conversion Kit Contains: Qty. 1 1 1 Part # 904-390 904-529 918-590 1 1 908-528 910-037 1 918-484 Description Burner Orifice #52 5/32" Allen Key Label "Converted to LPG" Red "LPG" label LPG Injector (Pilot Orifice) Instruction Sheet 8) Remove burner orifice with a 1/2" wrench.
INSTALLATION AERATION ADJUSTMENT LOG SET INSTALLATION The burner aeration is factory set but may need adjusting due to either the local gas supply, air supply or altitude. Read the instructions below carefully and refer to the diagrams. If logs are broken do not use the unit until they are replaced. Broken logs can interfere with the pilot operation.
INSTALLATION 7) Place the Left Top Log D)02-46 on the pin on Log B)02-56 and on top of the cutout on Log A)02-65. 11) Position notch in Front Right Log G)02-48 on Log F)02-47 and push the bottom right edge against the bracket on the burner tray. DOOR INSTALLATION (Packaged Separately) 1) Open the two side panels. G)02-48 A)02-65 A)02-65 F)02 -4 7 D)02-46 B)02-56 C)02-44 Cutout Pin E)02-45 3) Close the door. The latch plate must be centered around the alignment pin. See diagram 2.
INSTALLATION GAS PIPE PRESSURE TESTING The appliance must be isolated from the gas supply piping system by closing its individual manual shut-off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig. (3.45 kPa). Disconnect piping from valve at pressures over 3.45 kPa. The manifold pressure is controlled by a regulator built into the gas control, and should be checked at the pressure test point.
INSTALLATION OPTIONAL REMOTE CONTROL Use the Regency® Remote Control Kit approved for this unit. Use of other systems may void your warranty. The remote control kit comes with a hand held transmitter, a receiver and a wall mounting plate. 1) Choose a convenient location on the wall to install the receiver and the receptacle box (protection from extreme heat is very important). Run wires from the fireplace to that location, use Thermostat Wire Table. 2) Connect the wires as per the wiring diagram above.
OPERATING INSTRUCTIONS OPERATING INSTRUCTIONS SHUTDOWN PROCEDURE 1) Read and understand these instructions before operating this appliance. 1) Use the thermostat or remote control to turn off the main burner. 2) Check to see that all wiring is correct and enclosed to prevent possible shock. 2) Turn the main gas control clockwise to the "OFF" position to turn off the pilot (push knob in slightly). 3) Check to ensure there are no gas leaks.
OPERATING INSTRUCTIONS COPY OF THE LIGHTING PLATE INSTRUCTIONS FOR YOUR SAFETY READ BEFORE LIGHTING This appliance must be installed in accordance with local codes, if any; if none, follow the National Fuel Gas Code, ANSI Z223.1/NFPA 54, or Natural Gas and Propane Installation Codes, CSA B149.1. (Australia: AS5601-2004, New Zealand: NZS 5261) WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
MAINTENANCE MAINTENANCE INSTRUCTIONS 1) Always turn off the valve before cleaning. For relighting, refer to lighting instructions. Keep the burner and control compartment clean by brushing and vacuuming at least once a year. When cleaning the logs, use a soft clean paint brush as the logs are fragile and easily damaged. 2) Clean glass (never when unit is hot), appliance, louvres, and door with a damp cloth. Never use an abrasive cleaner.
MAINTENANCE LATCH ADJUSTMENT PANEL DOOR The door latch may require adjustment as the door gasket material compresses after a few fires and after glass replacement. Turn the handle on the adjustable catch to tighten or loosen the latch. 1) Remove the door from the unit and place on a soft surface to prevent scratching. 2) Pull out the door gasket. 3) Remove the nuts holding the glass retainers in place. 4) Remove the glass retainers (sides, top and bottom) and the door catch plate. 5) Replace the glass.
MAINTENANCE FAN MAINTENANCE 3) Unclip the black and white wires from the fan motor. REMOVING VALVE If your fan requires maintenance or replacement it must be performed by an authorised person. Access to the fan is through the plate on the rear wall of the firebox. NOTE: the unit MUST NOT be operated without the fan access panel securely in place and correctly sealed. 4) Lift fan off of the 2 pins, tip back and pull through the opening.
MAINTENANCE 4) Remove the two outside frame pieces by removing two screws per side. See diagram below. 9) Carefully lift the burner tray assembly out. Be careful not to tear gaskets when lifting out the valve tray; these gaskets seal the valve from the exterior of the firebox. 5) At this point you should disconnect the gas at the valve. You can access it through the front now that the control panel is off, or you can access it through the rear pedestal cover plate. 6) Carefully remove the logs and embers.
PARTS LIST MAIN ASSEMBLY Part # Description 560-921 560-920 560-922 4) 750-532 8) 730-560 10) 640-034 Louvre Assy (Set) - Nickel Louvre Assy (Set) - Gold Louvre Assy (Set) - Black Door Screen (Australia Only) Relief Door Assembly Mounting Plate Gasket 560-519/P 11) 910-169/P 12) 910-714 16) 730-039 17) 904-257 18) 560-025 1) 19) 730-530 20) 730-525 21) 560-031 23) 904-258 24 Part # 24) 25) 26) 27) 948-255 * * 910-233 Fan Assembly (240 V) Fan Motor (240 V) Power Cord (240 V) 28) 29) 30) 31) 32) *
PARTS LIST BURNER & LOG ASSEMBLY Part # 52) 54) 55) 56) 57) 60) 66) 67) 68) 69) 71) Description 910-190 910-373 910-372 918-088 591-041F Piezo Ignitor & Nut Knob - Pilot Valve Extension Flame Adjusting Knob Decal - Control Panel Switch Plate 680-574/P 680-576/P 910-478 904-240 936-170 910-038 * W840470 730-935 730-528 904-390 Valve Assembly - NG Valve Assembly - LPG Valve - S.I.T. - NG/LPG #37 Orifice - NG Orifice Gasket Pilot Assy - S.I.T.
PARTS LIST DOOR ASSEMBLIES Part # 101) 105) 106) 107) 108) 111) 112) 208) 730-923 730-924 730-926 730-932 730-928 650-920 * 940-323/P 936-243 940-322/P * 750-015 940-325/P Description Brush Nickel Mitred Door - Complete Gold Mitred Door - Complete Black Mitred Door - Complete Gold Wrap Door - Complete Gold Panel Door - Complete Door Gasket Kit Ceramic Paper Side Glass Glass Gasket Centre Glass Door Frame Fibre Paper Door Glass Extrusion Wrap Glass *Not available as a replacement part.
WARRANTY Regency® Fireplace Products are designed with reliability and simplicity in mind. In addition, our internal Quality Assurance Team carefully inspects each unit thoroughly before it leaves our door. Regency Fireplace Products is pleased to extend this limited lifetime warranty to the original purchaser of a Regency® Product.
Register your Regency® warranty online www.regency-fire.com.au Reasons to register your product online today! • View and modify a list of all your registered products. • Request automatic email notification of new product updates. • Stay informed about the current promotions, events, and special offers on related products. • Help assure you get the most out of your warranty. • Eliminate confusion and frustration if warranty** service is required in the future.