FP90 Wood Fireplace Owners & Installation Manual Canadian Edition Regency High Efficiency EPA Certified Fireplace MODEL: FP90 www.regency-fire.com Tested by: 918-426j Installer: Please complete the details on the back cover and leave this manual with the homeowner. Homeowner: Please keep these instructions for future reference. fpi fireplace products international ltd. 6988 Venture St.
Thank-you for purchasing a REGENCY FIREPLACE PRODUCT. The pride of workmanship that goes into each of our products will give you years of trouble-free enjoyment. This product has been certified by the Environmental Protection Agency of the United States. This means that it meets the strictest standards in providing you with the latest in clean burning technology and efficiency. Specifications may vary widely. Consult with your FPI Dealer for local considerations. Keep those REGENCY FIRES burning.
FPI FP90 Wood Fireplace 3
Table of contents SAFETY LABEL Safety Label For FP90...................................................5 installation Product Details...............................................................6 EPA Certified...........................................................6 Options...................................................................6 Read Before You Install..................................................7 Installation Of Nailing Strips.........................................
MADE IN CANADA FPI Fireplace Products International Ltd.
installation Product Details INSTALLATION EPA Certified Emissions : 3.
installation Read Before You Install The Regency High Efficiency Epa Certified Fireplace This installation manual will enable you to make a safe, efficient and dependable installation of your fireplace and chimney system. Please read and understand these instructions before beginning your installation. PLEASE RETAIN THIS MANUAL FOR FUTURE REFERENCE. IMPORTANT: Please read and follow these rules for safety.
installation INSTALLATION Dimensions And Specifications The Regency is a wood burning fireplace featuring a self-contained heat-circulating system and castiron doors with large viewing windows. A set of andirons are installed in the firebox to properly position the fire, do not remove them. Note: Illustrations shown reflect “typical” installations with nominal dimensions and are for design and framing reference only. Actual installations may vary due to individual design preferences.
installation Clearances and Height Requirements The FP90 may be placed on or near construction materials. The combustion air kit, fire stop spacer and roof flashings (not chase flashings) may be placed directly on or against normal construction materials. The chimney requires a minimum 2" (51mm) clearance. A combustible mantle (to a depth of 10", 254mm) may be installed no closer than 18" (457mm) above the warm air vent or 55-1/2" (1410mm) from bottom of unit. No Combustibles on Face of Unit.
installation Installation Of Nailing Strips Fireplace Enclosure Framing 1) Assemble 3 Nailing Strip Spacer Plates to the left and the right Nailing Strips as shown below. As per the diagram, the framing of the main enclosure should not infringe on the area above the fireplace to the ceiling level. The rear and side walls as well as the face above the fireplace must not extend into the area above the unit.
installation Framing Details Fire Stop 2 x 6 Stud Wall with a 2 x 4 Header Straightrun for 8"(203mm) Hot Air Duct FINISHING MATERIAL FireStop 10" (254mm) NON-COMBUSTIBLE 50-3/4" (1289mm) 84" (64mm) 2 x 4 Framing Location Of Fireplace 1) Carefully select the proper location for heat circulation, aesthetics, chimney obstructions and clearance to side wall(s). With proper pre-planning, a slight adjustment of a few inches can save considerable time and expense later during construction and assembly.
installation Chimney System Considerations Regency’s FP90 Fireplace is to be installed with one of the following Chimney Systems only. Chimney systems only 7" (178mm) or 8" (203mm) diameter are to be used.
installation Installation Measurements / framing Details 60" (1524mm) WIDE INSIDE MIN. UNIT TO BE CENTERE D 30" (762mm) 3" (76mm) STAND-OFF 2x4 FRAMING FRONT OF UNIT ONLY COMBUSTION AIR TO OUTSIDE INSTALLATION 19" (483mm) 11" (279mm) 38" NOTE: (965mm) FRAMING TO BE AGAI NST STAND-OFFS ONLY 10" (254mm) 60"(1524mm) WIDE INSIDE CHASE MIN. 2X 4, 24" (610mm) 50 3/4" (1289mm) 2X 6, 2X 8O N EN 11" (280mm) 2x4 D VENT TO OUTSIDE COMBUSTION AIR 2x4 18" (457mm) 46"(1168mm) MIN.
installation Assembly Steps INSTALLATION Note: The following steps represent the normal sequence of installation. Each installation is unique, however, and might require different steps. Each step is dealt with in detail in the following pages. 1) Install stand-offs and insulation strip to the unit. See Installing the Stand-offs section on this page. 2) Complete framing and installation of nailing strips for the FP90. I M PORTANT: Remove gold accessories such as louvers while installing to avoid marking.
installation The performance of your unit is governed to a very large extent by the chimney system. Too short a chimney can produce poor drafting which in turn can cause difficult start-up, dirty glass, smoking out door and even reduced heat output. Too tall a chimney may prompt excessive draft which can result in very short burn times and excessive heat output. The chimney must extend at least 3ft. (0.9m) above its point of penetration of the roof. It must also be at least 2ft. (0.
installation TABLE 1 INSTALLATION Required Firestop, Radiation Shield, Or Attic Insulation Shield Model 1st Floor 2nd Floor into Attic CF Sentinal Intermediate Joist Shield Attic Insulation Shield Super Pro 2100+ Attic Insulation Shield Attic Insulation Shield Super Vent 2100+ Attic Insulation Shield Attic Insulation Shield Security S2100+ Radiation Shield Fire Stop Insulation Radiation Shield Attic Radiation Shield Oliver Macleod Project HT6000+ Radiation Shield Fire Stop Insulated Attic
installation Wiring The Fp90 Jakel AX-2495 Blower Plan View Field wire main power supply to fireplace blower system. (All electrical connections should only be performed by a licensed/certified electrician). Angle View Caution: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation.
installation 1) Remove the screw from the vent hole cover (vent cover 'A') on top of the unit. 2) Take the connector collar and press and rotate it into the hole to cut through the insulation layer. Remove the collar and remove insulation from the collar. The screws for the inner cover should be exposed. INSTALLATION 3) Remove the screws from the inner cover (vent cover 'B') and slide it back under the insulation. 4) Extend flex vent and pull the insulation sleeves over the 8” (203mm) diameter flex vents.
installation Non-Combustible Material INSTALLATION Do not restrict air flow through the top and bottom louvers of the fireplace. This will cause overheating and possible ignition of surrounding materials. Top louver maybe closed only if gravity feed kit option is used. Diagram 1 Masonry Retainer Kit Option For a non-selfsupporting veneer finish only. 1) Framing and plywood cannot extend past the side and top stand-off spacers.
installation 6) Depending on the height of the hearth in front of the unit, it may be necessary to trim the bottom of the mesh sides (B) to fit. Mark and drill holes for side pieces. Attach with washers and screws. C 3/4" (19mm) Metal Filler Strips A 60" (1524mm) 2-1/2" (64mm) 2-1/2" (64mm) INSTALLATION 1-1/4"(32mm) Stand-off Spacers B B 7) Place the top metal filler strip in between stove and framing to cover the stand-off space.
installation Masonry Liner / Bricks Glass Installation Secondary Air Tube Installation Insulated refractory panels are included to extend the life of the fireplace and help radiate heat more evenly. Make sure Insulating Paper is in place along the bottom, side and rear before bricks are put into place. Remove the wire retainer from the doors, and place the glass in the doors, making sure that the glass gasketing will properly seal your unit.
installation Ash Drawer Kit Option During constant use, ashes should be removed every few days. The Ash Drawer Kit option provides a convenient and easy way to keep your wood stove clean. This ash drawer kit can only be used with the fireplace unit. INSTALLATION Safety Precautions Ash Drawer Kit Installation Ash Drawer Operating Guideline 1) Remove the bricks from the floor of the firebox. 1) Only clean ashes out of the fireplace when the unit has cooled down.
installation FP90 fanINSTALLATION installation FAN NOTE: If optional Ashtray is installed, it must be removed before installing the fan. The receptacle Box must be wired for the fan cable to be plugged into. 1) Remove the thumb screw from the fan transfer tray. 2) Slide fan transfer tray fully out through the bottom louver opening. 3) Mount the fan bracket onto the fan transfer tray using the two locating pins.
FP90 installation INSTALLATION 7) Slide the thermodisc/cover assembly into the bracket clip on the underside of the firebox. Check that no wire will touch the hot surfaces. masonry cover plate installation THE TOP IS ANGLED BACK AT 5 DEGREES TO ENSURE THAT THE TEMPLATE FITS TIGHT TO THE UNIT. THE TOP WILL BECOME MORE UPRIGHT AS THE TEMPLATE IS TIGHTENED TO THE SURROUND MOUNTING BRACKETS 5° 39.250" (997mm) INSTALL FOUR #8x1/2 SCREWS AT THESE LOCATIONS TO ATTACH THE SURROUND TEMPLATE SIDES TO THE TOP.
installation WARNING: KEEP MASONRY MATERIAL AT LEAST 1/2" (13mm) FROM THIS TOP FACING GUIDE. THIS IS REQUIRED TO PREVENT MASONRY FACING MATERIAL FROM HITTING THE TOP STIFFENER LOCATED ON THE BACK OF THE SURROUND WHICH IS HIGHER THAN THIS EDGE. INSTALLATION INSTALL THE SURROUND TEMPLATE ONTO THE UNIT WITH THE SAME MOUNTING SCREWS AS THE SURROUND.
installation WOOD FIREPLACE EX90 / R90 finishing trim kit installation FINISHING TRIM KIT 1) Unit must be installed correctly according to the specification in the manual. The nailing strips must be attached to the top and sides of the unit. They must be positioned so that they are set-back ½” (13 mm) from the face of the unit. This will allow for the wall sheathing to be flush with the face of the unit and allow the trim to be installed correctly (refer to Diagram 1).
WOOD FIREPLACE EX90 / R90 installation 2) Make sure the insulation under the top stand-off is up against the back of the top nailing strip. 3) Fasten the nailing strips to the framing. 4) Install both the left and right side trim (see labels for orientation). The side trims have slotted holes to allow the sides to be adjusted once installed to ensure the top corners will fit tight. Fasten the trim to the nailing strips with the screws provided, (#8 x 9/16”) in the center of each slot.
installation FIREPLACE SCREEN INSTALLATION fireplace screen installation EX90 / R90 INSTALLING THE SCREEN ON THE FIREPLACE 1) 1 or 2 handles can be installed on the screen. Layout location of the handle using the backing plate as a guide and widen two holes in the screen with a screw driver to let the screws for the handle through. 1) Ensure doors are opened enough to allow fire screen to be installed.
installation WOOD FIREPLACE R90 regency louver installation REGENCY LOUVERS Installing the Top Louver Installing the Bottom Louver 1) Add two (2) screws (¼-20 X ½”) to the front of the fireplace for mounting the top louver. The screws must be left loose to allow the top louver to slide onto them. Adjustment of theses screws will be needed to get the louver to sit flush with the front of the fireplace. 1) Fasten the bottom louver frame onto the front of the fireplace using two (2) screws (¼-20 X ½”).
installation WOOD FIREPLACE EX90 excalibur faceplate installation EXCALIBUR FACEPLATE NOTE: Before installing the fireplace the facing guide must be installed. 2) Install the top louver opening adapter to the face of the unit with five (5) screws (¼-20 x ½”). 3) Attach the sides of the top louver opening adapter to the left and right facing guides with two (2) screws (#8 x ½”). 1) Remove the left and right door from the fireplace.
WOOD FIREPLACE EX90 installation ACCENT KIT INSTALLATION excalibur accent kit installation 1) Remove the handles by removing the nut and screw. Install the new handles by placing them in position over the holes on the surround louver. Put the screws through the holes and secure them by tightening the nut. 3) Remove the 2 studs on the sides of the Hood. Insert the new studs through the holes and secure them by first putting on the washer and then tighten the nut.
HEATWAVE KIT (Not epa approved) Listings And Code Approvals General Information This Kit has been approved for use with Models EX90 / R90. This kit has been tested in accordance with National Safety Standards, and has been certified by OMNI Test Laboratories for installation and operation in Canada as described in these Installation and Operating Instructions.
HEATWAVE KIT (Not epa approved) Minimum Framing Clearances * Wall studs must be 16" on center for mounting fan housing. * Fan Housing: Maintain a 1/4" (6mm) clearance from fan housing to combustible material. Installation NOTE: Installation of Heat Wave duct kit should be done prior to drywall installation. A) R90 / EX90 Models: 1) Remove the cover plate from the fireplace side and discard. * Wall Registers must be 4"(102mm) from floor above or ceiling below.
HEATWAVE KIT (Not epa approved) Oval Air Duct: Attach the round-to-oval adaptor to the fireplace starting collar and a 6" oval duct (not supplied) to the adaptor. Complete the duct run and attach the oval duct to the fan housing. Round and Oval Duct: A combination of 6" round and 6" oval duct can be used in the duct run. Oval duct components are not supplied but can be purchased from an HVAC supplier. 4) Install the variable speed Wall Rheostat (with OFF setting) in a convenient location.
OPERATING INSTRUCTIONS Operating Instructions Draft Control Both the primary and air wash drafts are controlled by the control rod located behind the bottom louver. To increase your draft, pull to the right for open, to decrease push to the left for closed. WARNING: Never build a roaring fire in a cold stove. Always warm your stove up slowly! 6) Once a bed of coals has been established, you may adjust the draft control to a low setting to operate the unit at its most efficient mode.
Maintenance Plated Finishes Glass Cleaning Chimney Cleaning The optional plated finishes on the louvers and surrounds requires little maintenance and needs only to be cleaned with a damp cloth. DO NOT use abrasive materials or chemical cleaners, as they may harm the finish and void the warranty. Keep doors and louvers off during construction to avoid damage. Only clean your glass window when it is cool.
Parts List Parts List- Firebox & Body Part # 1) 001-127 001-128 001-129 001-130 2) 001-122 001-123 001-124 001-302 3) 001-125F 001-273F 4) 001-274 5) 001-250 6) 001-161 7) 910-142 910-175/P 910-330 8) 001-911 942-110 820-375 9) 948-326 948-327 948-416 4 Part # Description Heat Deflector Top Stand Off Top - Right Side Stand Off Top - Left Side Support Top Stand Off Nailing Strip - Top Nailing Strip - Right Nailing Strip - Left Nailing Strip Spacer Stand Off Sides Stand Off Back Top Stand Off Insulation A
Parts List Parts List- Baffles, Door, Options Description Part # Part # Brick Liner - Bottom Left Vermiculite Liner - Left Side Vermiculite Liner - Right Side Brick Liner - Back Left Brick Liner - Back Right Vermiculite Liner - Bottom Baffle Firebox Top - Left and Right Brick Liner - Bottom Right Insulation Side Liner Insulation Back Liner Door Handle Assembly Complete - Left Door Handle Assembly Complete - Right Steel Handle - Left Door Steel Handle - Right Door Anchor Bracket - Left Handle 902-534 902
For Model: F1100 F3100 S3100 H2100 I1100 I3100 F2400 S2400 I2400 Z2510 FP90 WARRANTY Warranty Regency Fireplace Products are designed with reliability and simplicity in mind. In addition, our internal Quality Assurance Team carefully inspects each unit thoroughly before it leaves our door. FPI Fireplace Products International Ltd. is pleased to extend this limited lifetime warranty to the original purchaser of a Regency Product. This warranty is not transferable.
Register your Regency® warranty online www.regency-fire.com Reasons to register your product online today! • View and modify a list of all your registered products. • Request automatic email notification of new product updates. • Stay informed about the current promotions, events, and special offers on related products.