www.regency-fire.com C33 Classic Freestanding Gas Stove Owners & Installation Manual Classic C33 model shown above features optional gold plated door and gold legs. MODELS: C33-NG2 Natural Gas C33-LP2 Propane WARNING: FOR YOUR SAFETY If the information in these instructions are not followed exactly, What to do if you smell gas: a fire or explosion may result causing property damage, Do not try to light any appliance personal injury or loss of life.
To the New Owner: Congratulations! You are the owner of a state-of-the-art Gas Stove by Fireplace Products International Ltd. The Regency Gas Series of hand crafted appliances has been designed to provide you with all the warmth and charm of a woodstove, at the flick of a switch. The models C33-NG2 and C33-LP2 have been approved by Warnock Hersey for both safety and efficiency. As it also bears our own mark, it promises to provide you with economy, comfort and security for many trouble free years to follow.
TABLE OF CONTENTS Page Page Safety Label Safety Label ............................................................. 4-5 Installation Before you start .......................................................... 6 General Safety Information .......................................... 6 Installation Checklist ................................................... 7 Clearances to Combustibles ....................................... 7 Optional Fan Installation ..............................................
SAFETY LABEL This is a copy of the label that accompanies each CLASSIC Freestanding Gas Stove - Natural Gas. We have printed a copy of the contents here for your review. The safety label is located on the back panel. NOTE: Regency units are constantly being improved. Check the label on the unit and if there is a difference, the label on the unit is the correct one. FPI Fireplace Products International Ltd. Delta, BC, Canada Serial No.
SAFETY LABEL This is a copy of the label that accompanies each CLASSIC Freestanding Gas Stove - Propane. We have printed a copy of the contents here for your review. The safety label is located on the back panel. NOTE: Regency units are constantly being improved. Check the label on the unit and if there is a difference, the label on the unit is the correct one. FPI Fireplace Products International Ltd. Delta, BC, Canada Serial No.
INSTALLATION BEFORE YOU START Safe installation and operation of this appliance requires common sense, however, we are required by the Canadian Safety Standards and ANSI Standards to make you aware of the following: INSTALLATION AND REPAIR SHOULD BE DONE BY A QUALIFIED SERVICE PERSON. THE APPLIANCE SHOULD BE INSPECTED BEFORE USE AND AT LEAST ANNUALLY BY A PROFESSIONAL SERVICE PERSON. MORE FREQUENT CLEANING MAY BE REQUIRED DUE TO EXCESSIVE LINT FROM CARPETING, BEDDING MATERIAL, ETC.
INSTALLATION 2) If required, adjusting the primary air to ensure that the flame does not carbon. First allow the unit to burn for 15-20 min. to stabilize. 3) Check for proper draft. CAUTION: Any alteration to the product that causes sooting or carboning that results in damage is not the responsibility of the manufacturer. CLEARANCES TO COMBUSTIBLES OPTIONAL FAN INSTALLATION Important: Disconnect the power supply before installation or servicing.
INSTALLATION Wiring 11) Remove the dummy plug from the right side of the bottom shield or pedestal and install the supplied fan switch. 12) Attach hot wire from power cord to the thermodisc. 13) Slide the thermodisc under the bracket. 16) Pull power wire back and put strain relief grommet in place as per diagram 4. PEDESTAL ASSEMBLY 17) Reverse steps 3-1 to complete installation. Note: The #8 ground lug is a dedicated ground for mobile home use only.
INSTALLATION LEG AND BOTTOM SHIELD ASSEMBLY These instructions apply to the steel leg, painted cast leg and the gold plated cast leg. It will be easier to attach the legs to the stove if it is tipped on its back (preferably on a soft surface to prevent scratching). 1) Remove the 4 bolts in the underside of the base and discard.
INSTALLATION Installing into Existing Woodstove Flue System GAS PIPE PRESSURE TESTING SYSTEM DATA (For 0 to 2,000 feet altitude) 1) Clean existing chimney system. 2) Install stove pipe adapter 3) Install any reducers that may be needed to fit 6" flue pipe adapter. 4) Run 4" flex liner into existing chimney. 5) Slip liner through 6" flue pipe and hook up to flue collar with screws. Note: For ease of installation, use a slip section when installing with a vertical flue pipe.
INSTALLATION Valve Description 1) Gas cock knob 2) Manual high/low adjustment 3) Pilot Adjustment 4) Thermocouple Connection 5) Main Operator 6) Outlet Pressure Tap 7) Inlet Pressure Tap 8) Pilot Outlet 9) Main Gas Outlet 10) Flange Securing Screw Holes 11) Alternative TC Connection Point 12) Thermoelectric Unit 13) Additional Valve Mounting Hole 1) Start all exhaust fans in the home and then close all doors and windows in the room. 2) Light the unit and set controls to maximum.
INSTALLATION Do not put the rock wool directly on the burner. Close the door and turn the unit on as per lighting instructions. Watch the flame to see if it flows smoothly around from one end to the other. (Use Extreme Caution and ensure proper light off of burner.) OPTION 1: REMOTE CONTROL INSTALLATION OPTION 3: WALL THERMOSTAT INSTALLATION Can be used with Options 1 or 2 but not both. Can be used with Options 2 or 3 but not both. Use the Regency Remote Control Kit approved for this unit.
INSTALLATION WIRING DIAGRAM This heater does not require a 120V A.C. supply for operation. In case of a power failure, the burner switch and the optional remote control/ thermostat will continue to operate. However, a 120V A.C. power supply is needed for the fan/blower operation. Caution: Ensure that the wires do not touch any hot surfaces and are away from sharp edges. CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation.
OPERATING INSTRUCTIONS OPERATING INSTRUCTIONS LIGHTING PROCEDURE MAINTENANCE INSTRUCTIONS 1) The FIRST FIRE in your stove is part of the paint curing process. To ensure that the paint is properly cured, it is recommended that you burn your fireplace for at least four (4) hours the first time you use it with the fan on. When first operated, the unit will release an odour caused by the curing of the paint and the burning off of any oils remaining from manufacturing.
OPERATING INSTRUCTIONS COPY OF THE LIGHTING PLATE INSTRUCTIONS FOR YOUR SAFETY READ BEFORE LIGHTING This appliance must be installed in accordance with local codes, if any; if not, follow the current CAN1-B149/ANSI Z 223.1 (Australia: AG601, New Zealand: NZS 5261) WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
MAINTENANCE CAUTION: ANY SAFETY SCREEN OR GUARD REMOVED FOR SERVICING AN APPLIANCE MUST BE REPLACED PRIOR TO OPERATING THE APPLIANCE. CLOTHING OR OTHER FLAMMABLE MATERIAL SHOULD NOT BE PLACED ON OR NEAR THE APPLIANCE. NEVER OPERATE THE APPLIANCE WITHOUT THE GLASS PROPERLY SECURED IN PLACE. GENERAL VENT MAINTENANCE Conduct an inspection of the venting system at least annually. Recommended areas to inspect are: 1) Check areas of the Venting System which are exposed to the elements for corrosion.
MAINTENANCE LOG REPLACEMENT The unit should never be used with broken logs. Turn off the gas valve and allow the unit to cool before opening door to carefully remove the logs. The pilot light generates enough heat to burn someone. If for any reason a log should need replacement, use only Regency replacement logs. The position of these logs must be as shown in the diagram under Log Installation.
MAINTENANCE REMOVING VALVE ASSEMBLY 1) Shut off gas supply. 2) If optional fan is installed, disconnect power source to stove. 3) Remove access panel. a) Front panel on pedestal model. See diagram 1. b) Panel from bottom of leg shield. See diagram 2. Note: Access panel only has to be loosened to be taken out. 8) If optional fan is installed, remove thermodisc to bracket by removing three (3) phillips head M5 screws. 9) Remove front cover with Piezo Igniter by removing two (2) sheet metal screws.
PARTS LIST MAIN ASSEMBLY Part # Description 1) 846-913 846-915 Door Assy-Gold (no glass) Door Assy-Black (no glass) 3) 4) 5) 6) 7) 9) 10) 12) 13) 14) 15) 16) 17) 19) 846-302 936-243 846-920 * 948-170/P 846-973 910-250 846-570 846-918 * * * 471-031 948-101 Small Glass Glass Gasket (7/8") Glass Retainer Clips (8/set) Screw 1/4 - 20 x 3/8" Small Glass Retainer Door Handle/Latch Assembly Spill Switch 7/8" Gasket Repair Kit Hinge Cap - Gold (2/set) Screw #10 - 24 x 3/4" 1/4" split lock washer Screw #10 -
PARTS LIST BURNER & LOGS Part # Description 910-190 * 908-672 Piezo Ignitor & Nut Control Panel Control Panel Decal 68) 69) 70) 462-560/P 462-561/P 910-378 910-380 910-034 910-035 904-604 904-390 948-279 948-294 948-232 Valve Assembly - S.I.T. - NG Valve Assembly - S.I.T. - LP Valve S.I.T. - NG Valve S.I.T. - LP Pilot Assembly-3 flame-S.I.T. -NG Pilot Assembly-3 flame-S.I.T.
PARTS LIST BASE OPTIONS 100) 102) 103) 108) 109) 110) 121) 140) 142) Part # Description 490-921 948-216 904-257 * 910-246 910-272 * * Complete Floor Shield Regency Logo Magnetic Catch (Large) 11" Pedestal Hinge Burner ON/OFF Switch (2-way) LT.
NOTES _____________________________________________________________________________________ ____________________________________________________________ __________________________________________________________ ____________________________________________________________ _______________________________________________________ _____________________________________________________ __________________________________________________________ _________________________________________________________ ___________
WARRANTY Regency Fireplace Products are designed with reliability and simplicity in mind. In addition, our internal Quality Assurance Team carefully inspects each unit thoroughly before it leaves our facility. FPI Fireplace Products International Ltd. is pleased to extend this limited lifetime warranty to the original purchaser of a Regency Product. This warranty is not transferable.
Regency fireplace products are designed with reliability and simplicity in mind. In addition, our internal Quality Assurance Team carefully inspects each unit thoroughly before it leaves our door. Fireplace Products International Ltd. is pleased to extend this Limited Lifetime Warranty to the original purchaser of a Regency Product. See the inside back cover for details. Register your Regency online at http://www.regency-fire.