FireWire-Ultra SCSI Converter FR1SX User’s Guide JAN. 2003 Rev. 3.
FR1SX 1.Introduction .................................................. 1 1-1.Package Confirmation .............................................. 1 1-2.System Requirements and Restrictions ................ 2 1-3.Front/Back Side Function ........................................ 4 2.Installation .................................................... 5 2-1.Connecting the FR1SX to a SCSI device .............. 5 2-2.Connecting the FR1SX to a PC ............................... 7 2-3.
B.How to configure the SCSI parameters ..................... 34 4-2-2.Installing on Mac OS X ..................................... 38 A.How to update the FR1SX Firmware ......................... 40 B.How to configure the SCSI parameters .................... 41 5.Troubleshooting ......................................... 44 5-1.General Hardware Troubleshooting ..................... 44 5-2.When you fail to copy files ...................................... 45 5-3.When a new drive letter is not assigned .......
1.Introduction This User’s Guide describes how to install, use, and troubleshoot the FireWire -Ultra SCSI Converter FR1SX(called FR1SX in this User’s Guide). The information in the README file on the CD-ROM may include the latest information. Be sure to read the file as well. 1-1.
1-2.System Requirements and Restrictions OS •Mac OS X-10.1.x or above/Mac OS 9.1 or above •Windows XP/2000/Me/98SE SCSI device •High-Density 50 pin female SCSI-2 connector on a SCSI device •Term-Power output capability (Caution)As FR1SX gets electric power from Term-Power on SCSI bus, this output capability is required. If Term -Power output is not available at your SCSI device such as iomega zip drive, you must use an OPTIONAL AC Adapter(sold separately). Refer to Chapter 5-4 and 7.
•The original SCSI based drivers or application software for your SCSI devices may not work with the SCSI device through the FR1SX. •FR1SX doesn’t support the following function: -Multiple LUN(Logical Unit Number) •Some scanners may not work with the FR1SX. For more information, refer to our web site(www.ratocsytems.com/english). •You can’t boot up system from SCSI devices.
1-3.Front/Back Side Function Power LED (Green) AC Adapter jack 6 pin FireWire (IEEE1394) port Fig. 1 Front Side Fig. 1 shows the front side layout of the FR1SX. Power LED light-on state indicates the FR1SX is powered and ready to work. If this LED doesn’t come on, refer to Chapter 5-4 and 7. High-Density 50 pin SCSI connector Push Button Fig. 2 Back Side Fig. 2 shows the back side layout of the FR1SX. You can connect a High-Density 50 pin SCSI device, using the Push Button.
2.Installation Follow the steps through to connect your SCSI device to the FR1SX, and connect it to a PC/Mac: 2-1.Connecting the FR1SX to a SCSI device Terminator Fig. 3 1)Make sure the SCSI device is in Power-OFF state. Connect the FR1SX to a SCSI device, as Fig.3 shows. If you have a SCSI device with a Low-Density Centronics 50 pin or DB25 connector, you can order an OPTINAL Adapter. In such a case , refer to Chapter 5-6 and 7.
2)Make sure that the SCSI device has a SCSI ID except 7. You can usually change a SCSI ID with a switch on the back of the SCSI device. For more information, refer to the SCSI device manual. 3)Attach an external active terminator to the SCSI device, as Fig.3 shows. If the SCSI device has an internal terminator and the switch, set it on state instead of attaching the external active terminator. Refer to the SCSI device manual if you are not sure how to terminate the SCSI device.
Windows 2-2.Connecting the FR1SX to a PC You can now hot plug in the FR1SX to a PC’s available 1394 port. Follow the steps through: 1)If your PC is powered down, start it now. 2)Connect the FR1SX to the 1394 port via the 1394 cable, as Fig.4 shows. 1394 port 1394 cable Fig.
Windows 3)Power up your SCSI device. Make sure the FR1SX’s Power LED comes on. If the LED doesn’t come on, refer to Chapter 5-4. 4)If a new drive is assigned at My Computer, as shown below, you have successfully installed the FR1SX. When you want to remove it from the PC, you must click the hardware removable icon at the TaskBar as shown below and select [Stop xxxDisk(X:)]. You will see the message box saying “you can safely remove the device”. Click [OK]. You can now remove it.
Follow the steps through to install it: a)Click Start menu on the TaskBar. b)Select Windows Update. (http://v4.windowsupdate.microsoft.com/en/default.asp) c)The following screen will appear. Click Scan for updates. 9 Windows 5)Windows 98 Second Edition Storage Supplement Update If you use Windows 98 SE, you need to install Storage Supplement Update available through Microsoft web site. This component improves 1394 storage performance and also installs a Safe Removal Utility.
Windows d)The following screen will appear. Click Windows 98 and Windows 98 Second Edition. Find Storage Supplement Update and click Add button. And then, click Review and install updates. e)The following screen will appear. Make sure Storage Supplement Update is shown. If you don’t want to install any updates other than Storage Supplement Update, click Remove button. To install the Storage Supplement Update, click Install Now and follow the on-screen instructions.
2-3.Connecting the FR1SX to a Mac FireWire port FireWire cable Fig. 5 11 Macintosh You can now hot plug in the FR1SX to a Mac’s available FireWire port. Follow the steps through: 1)If Mac is powered down, start it now. 2)Connect the FR1SX to the FireWire port via the FireWire cable, as Fig.5 shows. 3)Power up your SCSI device. Make sure the FR1SX’s Power LED comes on. If the LED doesn’t come on, refer to Chapter 5-4.
Macintosh 2-4.B’sCrew SIM driver If you have the following devices/software((1)-(4)) and intend to use them with the FR1SX on MacOS 9.x, you must install B’sCrew SIM driver. After installing it, you can use them on MacOS 9.x. But please note this B’sCrew SIM driver doesn’t work on MacOS X. This driver runs on MacOS 9.x only. (1)SCSI Film Scanners/Flat Bed Scanners. The scanner TWAIN driver has only SCSI API. (2)SCSI Removable Storage Devices such as ORB. The Disk Utility software has only SCSI API.
This B’sCrew SIM driver has the following restrictions: (1)The SIM Driver mode on FR1SX firmware operating mode must be set enable(Default setting is enable). You can set or reset this mode with the SCSI Configuration utility. Refer to section B in the Chapter 4-2-1. 13 Macintosh (2)The SIM driver doesn’t support FireWire Plug and Play, Hot Swapping because the original SCSI API doesn’t include these features.
(6)B’sCrew SIM FireREX1 file is copied in the [Extensions] folder. This B’sCrew SIM FireREX1 is enabled. Macintosh Only when you want to use the devices/software((1)-(4)) described in Page 12, you must set the B’sCrew SIM FireREX1 enabled(The B’sCrew SIM FireREX1 is set enable when this driver has been installed). If you don’t use the devices/software((1)-(4)), set the B’sCrew SIM FireREX1 disabled with the [Extensions Manager].
F.With the Devices and Volumes menu in the Apple system profiler, you can check to see if the scanner is recognized as a SCSI device. Macintosh (2)Example 2 If you want to share one FR1SX with two different SCSI devices such as a Scanner and HDD and use FireWire HDD driver which supports Hot Swapping and Plug and Play, please refer to the following steps. A.If you use a SCSI scanner, use it as described in Example 1. B.
Macintosh E.After the MacOS starting up, hook up the FR1SX/HDD to a FireWire port. F.The icon of the SCSI HDD will be mounted on the desktop. G.If you want to use the scanner again, unmount the HDD, remove it and set the B’sCrew SIM FireREX1 enabled again with the [Extesions Manager]. And then, follow Example 1-B to E. (3)Example 3 If you have two FR1SX and hook up them to a scanner and HDD each in daisy-chain, please refer to the following steps. A.
F.With the Devices and Volumes menu in the Apple system profiler, check to see if the scanner is recognized as a SCSI device. G.Hook up “SIM Disabled” FR1SX and the HDD to the FR1SX/scanner in daisy-chain. The HDD will be mounted automatically. The SIM driver detects the FR1SX operating mode and switch itself.
3.Repeater The FR1SX works as a FireWire repeater as Fig.6 shows. It extends the distance between one FireWire device and another FireWire device up to 9m (30 feet). In this case, an OPTIONAL AC adapter(sold separately) is required to provide the power. To purchase an AC adapter, refer to Chapter 7. AC adapter Jack OPTIONAL AC adapter Fig.
Windows 4.Installing Utility You can do the followings with the bundled utility: -You can configure settings for the SCSI device. -You can update the firmware on the FR1SX. -You can format a HDD, MO, Zip, Jaz, etc. Follow the steps to install it: If you use Windows, proceed to Chapter 4-1. If you use Mac, proceed to Chapter 4-2. 4-1.Installing on Windows 1)Click the hardware removable icon on the TaskBar. Select the pop-up menu saying [Stop xxx-Disk(X:)].
Windows 4-1-1.FR Disk Formatting and Partitioning Utility You can format a HDD, Jaz, MO, Zip drive, etc.,with this utility. (Caution) You can not format a CD-R, CD-RW or DVD-RAM. If you use Windows 98 SE or Windows Me, proceed to section A. If you use Windows 2000, proceed to section B. A.How to use FRFMTW9X on Windows Me/98SE Follow the steps through to format your SCSI drive: 1)Make sure the SCSI device is connected and powered on.
(Caution) All the devices, connected to USB, SCSI port on the PC besides 1394, will be shown. Be sure to select the drive connected to the FR1SX. 6)The following window will appear. Select [Initialize/Format media] from the [Edit] menu. 7)The Initialize/Format screen will appear. Select format type. If you want to do Low Level Format simultaneously, check [Low Level Format]. Then, click [OK]. 21 Windows 5)The following window will appear and select the drive you want to format.
Windows 8)If you selected IBM-PC/AT FDISK format at step 7), the message box saying [You should create partition next] will appear. Then, click [OK]. You will see the screen shown at the step 6) and select [Create Partition] from the [Edit] menu. And then, you will see the screen below. Select [File System] from the list box and set Partition size, using the slider bar. Then, click [OK] to create partition. If you selected Super FD format at step 7), you will see a screen similar to the following.
If you format a HDD, removable disk on Windows XP/2000, you usually use Disk Management in the Computer Management in Windows XP/ 2000. But, when you failed to format the HDD or a new drive letter will not be assigned after you have done Disk Management, you should do Low Level Format, using this format utility FRFMTW2K.EXE. Follow the steps through to do Low Level Format. 1)Make sure the SCSI device is connected and powered on.
Windows 4-1-2.FR Configuration Utility With this FR Configuration utility, you can configure settings for the SCSI device or update the old firmware data. (NOTE) Don’t connect any1394 devices/repeaters to a PC/the FR1SX directly or in between. 1)From the [Start] menu, select [Programs], then [RATOC FireWire Utility], and then [FR Configuration]. 2)The message box saying “reconnect the 1394 cable” will appear. Follow the message instruction.
Windows You can finish this FR configuration by clicking [EXIT]. Refer to section A for the [Firmware update Utility] information. Refer to section B for the [Config Utility] information.
Windows A.How to update the FR1SX Firmware With this firmware update utility, you can update the old firmware to the latest one available through our web site. To update the old firmware, follow the steps: 1)Select the [Firmware update Utility] button shown in the previous page. The following screen will appear. The highest row indicates the firmware data you are about to write. The lowest row indicates the firmware version the FR1SX has now.
Follow the steps through to use the SCSI configuration utility. 1)Start [FR Configuration]. Refer to Chapter 4-1-2 for how to start the FR Configuration. 2)Select the [Config Utility] button on the main menu. 3)The following window will appear. The setting items are as follows: [FireREX1/FR1SX SCSI ID] FR1SX SCSI ID is No. 7. [Transfer Mode] Default value is 20MB/s.You can set Max transfer rate from 20,10,5MB/s, Async. [Advanced] When you click this button, the window shown in the next page will appear.
Windows Advanced setting items as shown above are as follows. [Delay time between power on and SCSI bus reset] Default value is 0. You can set delay time for some SCSI devices which hang up if SCSI bus reset is issued right after the FR1SX gets powered. Set this value to 2 for Castle Wood ORB drive, Canon FB620S or Sharp JX-370. [Delay time between SCSI bus reset and SCSI command] Default value is 1.
[Enable SCSI bus reset] Default value is enabled.You can set whether the FR1SX issues SCSI bus reset to a SCSI device or not. [Enable START UNIT command] Default value is disabled. You have to enable START UNIT command for some SCSI devices which will not work if they does not receive this START UNIT command. [Enable parity check] Default value is enabled. You can set parity check enable or disable. [Target SCSI ID.] Default value is AUTO. You can set target SCSI ID No.
Macintosh 4-2.Installing on Macintosh 4-2-1.Installing on Mac OS 9.1.x/9.2.x As described below, duplicate Mac OS Base with the [Extensions Manager] before installing/using the utility. Then, change the duplicated set to the previous set after finishing the utility. If you use Mac OS X, refer to Chapter 4-2-2. 1)Open [Extensions Manager]. 2)Change selected set from your settings to [Mac OS Base] and click [Duplicate Set...]. 3)The following window will appear.
6)Start FR1 Installer-E at the [FRUTY] folder at the [FR1SX for OS 9] in the CD-ROM. License agreement will appear. Click [Accept]. 7)The following window will appear. Make sure the install location and click [Install]. Macintosh 8)The message saying “Installation was successful...” will appear. Click [Quit]. 9)[FRUTY] folder is created in the location you have confirmed at Step 7). Open the folder and start [FR1 Utility].The following window will appear. Click [OK].
A.How to update the FR1SX Firmware Macintosh With this firmware update utility, you can update the old firmware to the latest one available through our web site. 1)Before starting this utility, make sure the following 4 points: a.Open [Extensions Manager] and make sure selected set is [FIREREX1 CONFIGURATION] as described in Chapter 4-2-1. b.Make sure the following two driver is enabled with [Extensions Manager]. -FireREX1APIDriver / FireREXLoaderDriver c.
4)When you click [Select New Firmware Data File], the following window will appear. Select new firmware data file and click [Open]. 33 Macintosh 5)The window shown at the step 3) will appear again. Click [Write]. When the message says “Updating was successful”, click [OK]. Click [Quit] from the [File] menu. 6)Change selected set from [FIREREX CONFIGURATION ] to the previous settings you used before with the [Extensions Manager]. Then, restart your Mac for your chages to take effect.
B.How to configure the SCSI parameters 1)Before starting this utility, make sure the following points: Macintosh a.Open [Extensions Manager] and make sure selected set is [FIREREX1 CONFIGURATION] as described in Chapter 4-2-1. b.Make sure the following two driver is enabled with [Extensions Manager]. -FireREX1APIDriver / FireREXLoaderDriver c.Make sure the following two driver is disabled with [Extensions Manager]. -Authoring Support / FireWire Authoring Support/Disc Burner Extention d.
35 Macintosh [FireREX1/FR1SX SCSI ID] FR1SX SCSI ID is No. 7. [Transfer] Default value is 20MB/s.You can set Max transfer rate from 20,10,5MB/s, Async. [SIM Driver mode] This setting is usually checked(Enalbed). This item is used with B’sCrew SIM driver. Refer to Chapter 2-4. [Advanced] When you click this button, the window shown in the next page will appear. [Default] When you click this button, the default settings will be loaded. [Exit] Click this button to end this utility.
Macintosh Advanced setting items as shown above are as follows. [Target SCSI ID.] Default value is AUTO. You can set target SCSI ID No. [Enable parity check] Default value is enabled. You can set parity check enable or disable. [Delay time between power on and SCSI bus reset] Default value is 0. You can set delay time for some SCSI devices which hang up if SCSI bus reset is issued right after the FR1SX gets powered. Set this value to 2 for Castle Wood ORB drive, Canon FB620S or Sharp JX-370.
[Delay time until 1394 transaction start] Default value is 4.You can set delay time for some SCSI devices which will not receive any command if a next command is issued right after Start/Stop Unit command is issued. [Enable START UNIT command] Default value is disabled. You have to enable START UNIT command for some SCSI devices which will not work if they does not receive this START UNIT command. [Max Payload Size] Default value is 1024.
4-2-2.Starting on Mac OS X Macintosh With this firmware update utility, you can configure settings for the SCSI device or update the old firmware data. 1)Connect the FR1SX to the FireWire port and turn on the SCSI device. 2)Insert the bundled CD-ROM. 3)Open the [FR1SX for OS X] folder and then, open the [FRUTY_OS_X]. 4)Start [FR1Utility]. The following window will appear. Clcik [Enable FR1 Utility].
5)You will be requested to type in an administration password. Type in an administration password and click [OK]. Macintosh 6)You will be requested to restart your system. Click [OK] to restart your system. 7)Start the [FR1Utility] again. The following window will appear. - Proceed to section A for Firmware update Utility. - Proceed to section B for SCSI Configuration Utility.
Macintosh A.How to update the FR1SX Firmware With this firmware update utility, you can update the old firmware to the latest one available through our web site. 1)Start the FR1 utility as described at step 1-7 in chapter 4-2-2. 2)The main window will appear. Click [Select firmware data]. Select new firmware data on the next window and click [Open]. 3)Click [Start Firmware update] on the main window. 4)After updating the firmware data, the following window will appear. Click [OK].
B.How to configure the SCSI parameters With this firmware update utility, you can configure settings for the SCSI device 5)Click [Disable FR1 Utility] on the main window. 6)The following window will appear. Type in an administration password. Then, click [OK]. 7)You will be prompted to restart your system.Click [OK]. 41 Macintosh 1)Start the FR1 utility as described at step 1-7 in chapter 4-2-2. 2)The main window shown in the next page will appear. Refer to the next page for setting items information.
Macintosh [SIM Driver mode] This setting is usually checked(Enalbed). This item is only for MacOS 9.x. [Speed] Default value is 20MB/s.You can set Max transfer rate from 20, 10 ,5MB/s, Async. [Parity check] Default value is enabled. You can set parity check enable or disable. [FireREX1/FR1SX SCSI ID] FR1SX SCSI ID is No. 7. [SCSI bus reset] Default value is enabled.You can set whether the FR1SX issues SCSI bus reset to a SCSI device or not. [Target SCSI ID.] Default value is AUTO.
[Delay time between power on and SCSI bus reset] Default value is 0. You can set delay time for some SCSI devices which hang up if SCSI bus reset is issued right after the FR1SX gets powered. Set this value to 2 for Castle Wood ORB drive, Canon FB620S or Sharp JX-370. [Delay time until 1394 transaction start] Default value is 4.You can set delay time for some SCSI devices which will not receive any command if a next command is issued right after Start/Stop Unit command is issued.
5.Troubleshooting 5-1.General Hardware Troubleshooting n Make sure the FR1SX’s power LED comes on. If the LED does not come on, your SCSI device may not provide SCSI bus termination power. If the SCSI device can not provide it, an OPTIONAL AC adapter is required. For purchasing information, refer to Chapter 7. n Make sure the FR1SX is firmly connected to your SCSI device. n Make sure the 1394 cable is firmly connected to the FR1SX and a 1394 port on your PC or Mac.
5-2.When you fail to copy files When you come across an error message during copying files or the system locks up, you should phase down transfer rate with the SCSI configuration utility. If you use the older MO models made by FUJITSU such as M2512A, M2513A, the system sometimes locks up. If you use the older FUJITSU MO(M2512A, M2513A), remove the FR1SX from the SCSI device and attach the FR1SX to another SCSI device to set transfer rate to 10MB/sec with the SCSI configuration utility.
5-3.When a new drive letter is not assigned(Windows) When you connect a HDD which is not formatted or does not have partition, a new drive letter will not be assigned in [My Computer]. You need to format or create partition on the HDD. 1.When you use Windows Me/98SE, you can format your HDD and create partition, using “FRFMTW9X.EXE”. For more information, refer to section A in Chapter 4-1-1. 2.
5-4.When the green power LED does not come on (Win/Mac) Check the following points: 1)Make sure the SCSI device is powered on properly. 2)Turn off the SCSI device and check the FR1SX is attached firmly. And turn on the device again. If the LED does not come on even if above checking was made, refer to the user’s document of the SCSI device. SCSI specifications require Term-Power output capability as an optional, but some SCSI devices such as iomega Zip drive may not be implemented this capability.
5-5.When you connect two or more FR1SX in daisy-chain, your system can not recognize them (Win/Mac) Follow the steps to connect two or more FR1SX in daisy-chain. 1)Make sure all SCSI devices are powered off and then connect FR1SX to each SCSI device. 2)Connect the FR1SX in daisy-chain via 1394 cables. 3)Power up all the SCSI devices. 4)Connect a FR1SX to a 1394(FireWire) port on the PC/Mac via a 1394 cable.
5-6.How to attach to the SCSI-1(Centronics50P, DB25) device(Win/Mac) 1)If you have a SCSI device with a Low-Density Centronics 50 pin connector, a High-Density 50 pin(Female) to Low-Density Centronics 50 pin(Male) adapter(RCL-3005) is available from us. You can connect your SCSI device, using this adapter.For purchasing information, refer to Chapter 7. 2)If you have a SCSI device with a DB25 pin connector, a High-Density 50 pin(Female) to DB25 pin(Male) adapter(RCL-3025) is available from us.
5-7.Wrong drive name appears on the removable icon (Win98SE/Win Me) When you click the hardware removable icon on the TaskBar, you may see a wrong drive name. This happens on Windows 98 SE or Me.(The following screen shows a example when you connect a CD-R drive. It shows IEEE 1394 Disk, instead of CD-ROM.) Follow these steps through to show the right drive name. 1)Open [Device Manager].
5)You will see the next screen.Check [Display a list of all the drivers in a specific location, so you can select the driver you want] and click [Next]. 6)You will see the next screen saying “select the manufacturer and model of your hardware device”. Check [Show all hardware] and select the right drive name from the list. Click [Next]. Update Driver Warning message may appear. In such a case, just click [Yes]. 7)You will see the next screen saying “Windows driver file search for the device”. Click [Next].
5-8.Wrong device icon appears in [My Computer] (Win2000/XP) If you exchange SCSI devices on Windows2000/XP, as shown below, the device icon in [My Computer] will not change. You can still find the previous drive icon in [My Computer]. Change a device from To Icon in [My Computer] CD-ROM,CD-R/RW HDD/Jaz/Zip drive CD-ROM HDD/Jaz/Zip drive CD-ROM,CD-R/RW Removable Follow these steps through to update driver so that you can resolve this issue. 1)Right-click on [My Computer] and select [Properties].
4)If you have changed from a CD-ROM or CD-R/RW to a Removable disk or HDD, you can find a [RATOC Systems_Inc. IEEE1394-SCSI-3 IEEE1394 SBP2 Device] string under the [DVD/CD-ROM drives]. If you have changed from a Removable disk or HDD to a CD-ROM or CDR/RW, you can find a [RATOC Systems_Inc. IEEE1394-SCSI-3 IEEE1394 SBP2 Device] string under the [Disk drives]. Double click on the [RATOC Systems_Inc. IEEE1394-SCSI-3 IEEE1394 SBP2 Device] string to show its property.
5)Select [Driver] tab on the screen and click the [Update Driver] button. 6)[Update Device Driver Wizard] will start up. Click [Next]. 7)[Install Hardware Device Drivers] window will appear. Check [Search for a suitable driver for my device(recommended)] and click [Next]. 8)[Locate Driver Files] window will appear. Unchech all the options at Optional Search locations:. Click [Next]. 9) [Driver Files Search Results] window will appear. Click [Next].
5-10.Write error happens to Castlewood ORB(Win/Mac) The AC adapter the Castlewood ORB uses may not be able to provide enough termination power for the FR1SX to work. You should purchase an OPTINAL AC adapter. Refer to Chapter 7. 5-11.Castlewood ORB can not be recognized when you start your computer with ORB connected(Win/Mac) Set 2 seconds at [Delay time between power on and SCSI bus reset] with the SCSI configuration utility.
6.Registration and Tech-Support 6-1. How to Register We highly recommend to register yourself as our customer through our on-line registration. (http://www.ratocsystems.com/english/) 6-2. Software Update and Support -Utility UpdateThe latest utility is subject to change for improvement or bug fix.You can download the latest version from our web site. -Technical SupportYou can get a Tech support from RATOC at the following: (Open Monday - Friday,9:30A.M. to 5:00P.M.(PST)) RATOC Systems International,Inc.
7.Options Optional AC adapters, FireWire(IEEE1394) cables, etc. are available (sold separately) at the web site: 1.http://www.ratocsytems.com/english/ 2.http://www.firewireshop.
8.Specifications Product Name :FR1SX Transfer :SCSI •Max synchronous transfer 20MBytes/sec (When you connect an Ultra SCSI device) •Max synchronous transfer 10MBytes/sec (When you connect a SCSI-2 device) •Max asynchronous transfer 6MBytes/sec FireWire •100/200/400Mbps SCSI connector:High-Density 50 pin male SCSI-2 connector x 1 1394(FireWire) connector: 6pin x 2 Size:2.17 in (55 mm) (W) x 2.56 in (65 mm) (D) x 0.59 in (15 mm) (H) Weight:1.69 oz (48 g) Power Requirements :DC +4.25V to 5.
Appendix Trademarks -Windows is a registered trademark of Microsoft Corporation. -MacOS, PowerMacintosh, PowerBook and Mac logo are registered trademarks of Apple Computer,Inc. -Other brand and product names may be registered trademarks or trademarks of their respective holders. Regulatory Agency Notice FCC Compliance Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules.
60