The Deactivator DAV-200 deactivates any standard 8.2MHz deactivatable Labels. The Deactivator sends short bursts of approximate 10 μs. After this period the transmitter is switched off and the receiver becomes active. If a non- deactivated Label or Tag is near the deactivator antenna plate an ECHO signal is received and an audible internal Buzzer alarm is given (Option: external Buzzer). The electronic unit is line-synchronized via the power supply PSD-300.
X3 X1 X2 To DAV 300 DAV 200 2018-11 To DAV 300 Page 3
DAV 200 2018-11 Page 4
- DAV 200 X3 X2 X1 Cable 2 x 0.75 mm2 < 1 meter .
DAV 200 2018-11 Page 6
PSD 300 SYNC 12VDC GND SYNC DAV 200 2018-11 Page 7
DAV 200 X3 X2 X1 Cable 2 x 0.75 mm2 < 1 meter Copper wire 1-1.5 mm2 30cm x 30cm . .
Jumper setting: J1 Factory setting (default is OUT) J2, J3 & J4, J5 Matching of deactivation coil (for our standard pad DAP 300 no setting is required) J6 Factory setting (default is OUT) J7 Power line synchronization active (default IN) J8 Factory setting (default is OUT) J9 internal Buzzer (IN – Buzzer ON (default), OUT – Buzzer OFF) DAV 200 2018-11 Page 9
8.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.