Rain+Birdt ESP-Me enhanced modular controller User Manual FRI 830 AM
Symbols CAUTION: Symbol is intended to alert the user to dd important instructions or conditions that could seriously affect irrigation effectivity or controller operation. DIAL: Symbol indicates that the user is required to gg turn the dial on the controller to the appropriate position in order to follow subsequent instructions as described in that section. NOTE: Symbol is intended to alert the user to bb important operating functionality, installation or maintenance instructions.
English - User Manual Contents Questions?..............................................................II Check Box Contents..............................................III Station Numbering........................................................... 7 Module Configuration................................................ 7 Wiring Connections...............................................8 Connect Valves................................................................... 8 Connect Master Valve..............
Introduction Welcome to Rain Bird Thank you for choosing the ESP-Me Modular Controller from Rain Bird. FRI 830 AM For more than 70 years, the world’s top irrigation contractors have chosen Rain Bird for the highest quality products and services available worldwide.
Display Legend This manual uses USA domestic icons for illustration purposes. The following table lists the differences between the domestic and international display screen symbols. Choose your voltage below to determine the LCD symbols for your controller. Domestic vs. International Display Symbols 120V & 240V OFF 230V English Off Next Watering Day NEXT MO TU WE TH FR SA SU DAY MONTH YEAR HOUR MINUTE 1, 3, 5... ODD 2,4, 6... EVEN STATION 1, 3, 5...
Advanced Options Delay Watering For Basic Setup, see the Quick Reference Guide located inside the controller door. Delay watering if irrigation is not needed. Seasonal Adjust 1. Turn the dial to Delay Watering. Increase or decrease watering duration based on seasonal weather conditions. 2. Press or to set the DAYS REMAINING. The next watering days remaining will update on the display to indicate when watering will resume. 1. Turn the dial to Seasonal Adjust %. 2.
Installation Mount Controller Installation Checklist Choose Location When installing the ESP-Me controller for the first time, it is recommended that you complete the following steps in order. A check-off box is provided for each step: Check box contents (see page III) Gather installation tools (see below) 11 IN. 3 IN.
Connect Power Mount Controller WARNING: DO NOT plug in the transformer or cc connect external power until you have completed 2. 1. 1/8 IN. and checked all wiring connections. WARNING: All electrical connections and wiring cc runs must comply with local building codes. NOTE: Use wall anchors (not included) if needed. bb Electrical Specifications (230V only) 3. GND SENS 24 VAC 4.
Outdoor Model For 230V only: WARNING: Electric shock can cause severe injury or cc death. Make sure power supply is turned OFF before 3. connecting power wires.
Install Modules Module Configuration Why Proper Configuration Is So Important 1. Example of installation with station numbering gaps: A total of 19 stations are installed. The Base Module is installed in Bay 1 and uses Stations 1 through 4. A 6-Station Expansion Module is installed in Bays 2 and 3. A 3-Station module is installed in Bay 4 and uses 2. stations numbered 17 through 19.
Wiring Connections Connect Master Valve Connect the valve wires for each station and for a (optional) Master Valve, Pump Start Relay or Rain Sensor. Connect an optional Master Valve to the ESP-Me controller. GND 24 VAC CAUTION: Do not route the valve wires through the dd same opening as the power wiring. SENS CAUTION: Do not route the master valve wires dd through the same opening as the power wiring.
Connect an optional Pump Start Relay to the ESP-Me controller. bb The following Rain Bird Pump Start Relays are available in the USA only: RBSR24WG1 - Universal Pump Start Relay For the most up to date compatibility list of pump start relays, visit our website at: www.rainbird.com/ controllersupport GND SENS GND 1 2 3 4 VT = VALVE TEST 120 VAC JUMPER WIRES ON UNUSED STATIONS NOTE: Default run times for program A is 10 minutes bb for stations 1-4.
Connect Optional Rain Sensor (Wired or Wireless) Set Rain Sensor to Active (after installing a rain sensor and removing jumper wire on backplane) Connect an optional rain sensor to the ESP-Me controller. Set the controller to obey a rain sensor. NOTE: The ESP-Me Controller is not compatible with bb with a Normally Open rain sensor. It is designed for 1. Turn the dial to Rain Sensor. 2. Press or to select ACTIVE. use with a Normally Closed rain sensor.
Installing Optional Features Connect Optional Accessory NOTE: Use only Rain Bird approved devices with bb 5 pin accessory port. Unapproved devices may damage controller and void warranty. Remote Programming Program the front panel remotely on battery power. HOMEOWNER NOTE: The following bb do not require a 9V battery to maintain: Date and Time are maintained up to 10 years by an internal Lithium battery. Programs and Settings are permanently stored in controllers non-volatile memory.
Troubleshooting The Alert LED light on the ESP-Me controller front panel will light up to indicate an alarm condition: Battery Life If the display repeatedly shows “-- -- -- -- --” when using a 9V battery for remote programming, replace the battery. ALERT Programming Errors (blinking LED) Error Alert LED Error Message On Display Press RESET if the controller is not working properly. No Start Times are set BLINK NO START TIMES The Reset button resets the controller.
Frequently Asked Questions Problem Possible Cause Possible Solution Display shows a program is active, but system isn’t watering. Water source not supplying water. Verify there is no disruption to the main water line and that all other water supply lines are open and functioning properly. Wiring is loose or not properly connected. Check that field wiring and master valve or pump start relay wiring is securely connected at the controller and in the field. Field wires are corroded or damaged.
Electrical Issues (solid LED illuminated) Problem Possible Cause Possible Solution Display is blank, frozen or will not accept programming. Power not reaching the controller. Verify the main AC power supply is securely plugged in or connected and working properly. Controller needs to be reset. Press the Reset Button. For details see “Reset Button” section. An electrical surge may have interfered with the controller’s electronics. Unplug the controller for 2 minutes, then plug it back in.
Declaration of Conformity Rain Bird Corporation hereby declares that the ESP-Me irrigation controller families conform to the European Directives 2004/108/EC for “Electromagnetic Compatibility” and 2006/95/EC for “Low Voltage” Place San Diego Signature Full Name Ryan L. Walker Position Director Rain Bird Corporation 970 W. Sierra Madre Azusa, California 91702 U.S.A 626-963-9311 Rain Bird International, Inc. 145 North Grand Avenue Glendora, CA 91741 U.S.