To be the partner of your success CONTENTS MT5000/4000 SERIES HMI AND PLC CONNECTING GUIDE ....................................................... - 1 1 SERIAL COMMUNICATION PIN DEFINITION ............................................................................................- 1 2 PARALLEL PORT PIN DEFINITION ..........................................................................................................- 2 3 PRINTER CONNECTING CABLE DIAGRAM ................................................
To be the partner of your success 6.23 GE Fanuc Automation Inc........................................................................................................ - 99 6.24 HAIWELL.............................................................................................................................. - 108 6.25 HanG ...................................................................................................................................... - 110 6.26 Hitachi Inverter .....................
To be the partner of your success 6.67 THINGET Controller ............................................................................................................. - 286 6.68 Toledo DLoadCell .................................................................................................................. - 288 6.69 Trio motion controller ............................................................................................................ - 289 6.70 Unitronics ...................................
1 Serial Communication Pin definition MT5000/4000 Series HMI and PLC connecting guide 1 Serial Communication Pin definition Pin Designations COM0/COM2 (male) Pin Pin assignment of the 9-pin male, D-SUB, COM0/COM2. This port is used to connect MT5000/MT4000 series touch screens and provides RS-232/485/422 port. Note: The COM2 port is used for programming and debugging, and it is also used for communication, but only provides RS-232 port controller.
2 Parallel port pin definition 2 Parallel Port Pin Definition The parallel printer port on the back of case can be used to connect with various parallel port printers on the market. Printout The full series of MT5000/MT4000 products support printout function. The printing port will export data when the printing component works. The MT5000/MT4000 series touch screens support multiple printers, and Kinco HMItek Ltd. will continuously provide drivers for various brands of printers.
3 Printer connectiong cable diagram 3 Printer Connecting Cable Diagram 3.1 Parallel Printer Cable of SPRT SP-DN16PH/ WH4008A31-053 Printer Note: WH4008A31 support printing of 240 dots width. When use parallel interface, you should mount W1 block, parallel connect WA to WB for TTL level.
3 Printer connectiong cable diagram 3.2 Serial Interface Printer Cable of Bright Printer a. WH4008A31-053 serial print mode, pulling up W1 short circuit block by RS232 level. b. WH-A62R10 support printing of 190 dots width. Serial port printing mode via RS232 level, short circuit as follows: c. WH-A52Z20-30E125 support printing of 240 dots width. Serial port printing mode via RS232 level, short circuit as follows: d.
3 Printer connectiong cable diagram e. WH-E173R90-00E11720GA support printing of 192 dots width. f. WH-E191RB0-00E1182055 support printing of 576 dots width (24). Serial port printing mode via RS232 level 20 TXD RXD 19 18 BUSY 17 16 GND 15 3.3 Siupo Printer cable a. SP-E40004SK serial printer supports 240 dots width. 3.4 MY POS Printer cable a. MY-POS80K serial printer which supports 240 dots width. 25 pin. 3.5 Parallel Printer Cable of EPSON/HP Printer 3.5.
3 Printer connectiong cable diagram Printer 36pin male Terminal 1 STROBE 1 2 D0 2 3 D1 3 4 D2 4 5 D3 5 6 D4 6 7 D5 7 8 D6 8 9 D7 9 10 ACK 10 11 BUSY 11 12 PE 12 13 SLCT 13 14 Autofeeddxt 14 32 ERROR 15 31 INIT 16 36 SLCTIN 17 19 GND 18 GND 20 GND 19 GND 21 GND 20 GND 22 GND 21 GND 23 GND 22 GND 24 GND HMI 25pin female Terminal 23 GND 25 GND 24 GND 26 GND 25 GND 27 GND 28 GND 29 GND 30 GND 33 GND 3.5.
3 Printer connectiong cable diagram 3.5.
3 Printer connectiong cable diagram Printer 36pin male Terminal 1 STROBE 5 2 D0 4 3 D1 13 4 D2 8 5 D3 3 6 D4 12 7 D5 7 8 D6 2 9 D7 11 11 BUSY 10 14 Autofeeddxt 9 32 ERROR 15 31 INIT 14 36 SLCTIN 6 19 GND 1 HMI 4300series 15pin male Terminal 20 GND 21 GND 22 GND 23 GND 24 GND 25 GND 26 GND 27 GND 28 GND 29 GND 30 GND 33 GND 3.
3 Printer connectiong cable diagram HP Photosmart D5368 USB inkjet printer A4 SP-DN16PH Parallel Stylus micro printer 240 dots/line SP-RMDIV16PH Parallel thermal 240 dots/line WH4008A31-053 Parallel Stylus micro printer 240 dots/line WH4008A31 Parallel Stylus micro printer 240 dots/line WH4008A32-053 Parallel Stylus micro printer 240 dots/line WH-A52Z20-30E125 serial Stylus micro printer 240 dots/line WH-A52Z20-40E125 serial Stylus micro printer 240 dots/line WH-A62R10 Para
4 Download cable diagram 4 Download Cable Diagram 4.1 Download by Serial Port The COM2 port on the back of the case can be used to connect PLC RS-232 devices and can also be used to connect with the programming interface and setting interface of a PC. 4.2 Download by USB 4.3 Download by Network Ethernet Connecting PC and HMI use cross-ruling; communicating with hub or switch use Cross-over cable or cross-ruling. A. cross-ruling cable diagram: B.
4 Download cable diagram HMI Ethernet terminal RJ45 1 TX+ 2 TX3 RX+ 4 BD4+ 5 BD46 RX7 BD3+ 8 BD3- (orange,white) ( orange) (green,white) (bule) (bule,white) (green) (brown,white) (brown) Ethernet Hub or Switch RJ45 1 RX+(orange,white) 2 RX- (orange) 3 TX+ (green,white) 4 BD4+ (bule) 5 BD4- (bule,white) 6 TX(green) 7 BD3(brown,white) 8 BD3- (brown) - 11 -
5 Refresh kernel and rootfs 5 Refresh Kernel and Rootfs There are three methods to refresh kernel and rootfs: 1. Refresh kernel and rootfs by serial port; 2. Refresh kernel and rootfs by Ethernet port; 3. Refresh kernel and rootfs by USB port. Note: updated kernel and file system by USB, 4000 series, 5020 series screen and the Kinco HMIware software must be after the November 2009 version. 5.1 Refresh by serial port 1. Make a serial cable as follow: 2.
5 Refresh kernel and rootfs 4. Set sw2 to on, sw1 to off on the back of the panel after refresh, you can touch calibrate in the mode. Press the “+” until the panel show “TP adjust successful”, and then reset. 5. Make switches to default set and reset. 6. Re-download the project to panel. 5.2 Refresh by Ethernet port 1. Set sw1 and sw2 to off on the back of the panel. 2. Connect the panel with USB cable and set IP address. Open the Evmanager tool to click set.
5 Refresh kernel and rootfs Click “set” and set the IP in the “communication set” dialog box. 3. Set the IP OK, and then set sw1 to on, sw2 to off, at the same time to reset. Click “Write kernel” and “Write rootfs”. If you can’t refresh, check the IP and the cable. 4. Set sw2 to on, sw1 to off on the back of the panel after refresh, you can touch calibrate in this mode. Press the “+” until the panel show “TP adjust successful”, and then reset. 5.
6 Communication settings and guide of HMI connecting with controller 6 Communication Settings and guide of HMI connecting with Controller Note:Do not hot plug! 6.1 ABB Corporation Serial Communication Series CPU Link Module ABB AC31 O7KR51-V3.6 ABB AC500 PM571 PM581 PM591 Driver RS232 on the CPU unit RS485 RS232 on the CPU unit ABB AC31 Modbus RTU ABB AC500 System configuration Series CPU ABB AC31 O7KR51-V3.
6 Communication settings and guide of HMI connecting with controller ABB AC500:Default communication parameters 9600, 8, none, 1; station No. : 1 RS232 Supported Device ABB AC31 Device Bit Address Word Address Format Input bit I00.00-68.15 ------ DD.DD Output bit O00.00-68.15 ------ DD.DD M(0.0--99.15)U(233.00-255.15) ------ DDD.DD S000.00-125.15 ------ DDD.DD Input Register ------ IW00.00-68.15 DD.DD Output Register ------ OW00.00-68.15 DD.DD Internal Register ------ MW(0.
6 Communication settings and guide of HMI connecting with controller Internal Register (Double words) ------ MD0.00-7.15 D.DD Indirect Register (Double words) ------ KD0.00-7.15 D.DD ABB AC500 Device PLC Register Internal Register Internal Register (Double words) Bit Address Word Address Format MB0.0—8191.7 ------ DDDD.O ------ MW0.0—1.32767 D.DDDDD ------ MD0.0—1.16383 D.
6 Communication settings and guide of HMI connecting with controller ABB AC500 port2 RS232 6.
6 Communication settings and guide of HMI connecting with controller CompactLogix 1769-L20 1769-L30 1769-L31 1769-L32E 1769-L35E Channel 0 Channel 1 AB CompactLogix/ControlLogix ControlLogix 1756-L61 1756-L63 CPU Direct AB CompactLogix/ControlLogix Ethernet Communication (Direct Online Simulation disable) Series MicroLogix SLC500 PLC-5 CPU Link Module Driver MicroLogix 1100 MicroLogix 1400 CPU Direct (channel 1) MicroLogix 1000 MicroLogix 1100 MicroLogix 1200 MicroLogix 1400 MicroLogix 150
6 Communication settings and guide of HMI connecting with controller PLC-5 PLC-5/11 PLC-5/20 PLC-5/30 PLC-5/40 PLC-5/40L PLC-5/60 PLC-5/60L CompactLogix 1769-L20 1769-L30 1769-L31 1769-L32E 1769-L35E ControlLogix 1756-L61 Channel 0 RS232C Setting Your owner cable RS232C Setting Your owner cable RS232C Setting Your owner cable Connect Type Parameter Cable Ethernet Setting Your cable Channel 0 Channel 1 CPU Direct Ethernet System Communication Series MicroLogix SLC500 PLC-5 CPU L
6 Communication settings and guide of HMI connecting with controller SLC500 RS232 communication RSLogix500 software setting Note: Driver: DF1 Full Duplex; Error Detection: CRC.
6 Communication settings and guide of HMI connecting with controller CompactLogix/ControlLogix RS232 communication RSLogix5000 software setting Note: Protocol: DF1 Point to Point; Error Detection: CRC; Enable Duplicate Detection: Disabled.
6 Communication settings and guide of HMI connecting with controller Note: Define the new device in the RSLogix5000 before using the register in the HMI.
6 Communication settings and guide of HMI connecting with controller Example : Tag kk, s, b s, b to create Tags in the same way kk, the final results in the following tags: Note: 1. Controller internal registers communicate with touch-screen, you must first define tags in the RSLogix5000 software. Which can only be built in the Controller Tags, the tags set up elsewhere, Kinco HMIware is not available. 2.
6 Communication settings and guide of HMI connecting with controller Tag Number, you can refer to the RSLogix5000 manual. (3) Assign the Tag Name created by RSLogix5000 to the optional File Name: select “logic”--->”map PLC/SLC messages”.(Note: the state of program software change to offline) Note: You can not assign different Tag Names to the same File Number.
6 Communication settings and guide of HMI connecting with controller Ethernet Communication Setting HMI Network configuration - 26 -
6 Communication settings and guide of HMI connecting with controller PLC configuration Supported Device MicroLogix 1200 Device Bit Address Word Address Format Bit data file B10:0.0-254.15 ------ DDD.DD Bit data file B3:0.0-254.15 ------ DDD.DD Output data file O0:0.0-0.63 ------ DD.DD Input data file I1:0.0-0.63 ------ DD.
6 Communication settings and guide of HMI connecting with controller Integer data file bit level N_INT000000.00~254254.15 ------ FFFDDD.DD B_BOOL000000~254991 ------ FFFDDD ------ REAL000000~254254 FFFDDD Bit data file Floating point data file -----FFFDDD Integer data file INT000000~254254 Note: 1. FFF: file number; DDD: variable address. The correct format example as follow: file number112, variable address 87.12, format is 112087.12.
6 Communication settings and guide of HMI connecting with controller 1. Cable made by AB Corporation 2. Communication module AIC+ (Part No.
6 Communication settings and guide of HMI connecting with controller EtherNet cable Connecting PC and HMI use cross-ruling; communicating with hub or switch use Cross-over cable or cross-ruling. a. cross-ruling cable diagram: b.
6 Communication settings and guide of HMI connecting with controller System configuration Series CPU Link Module COM Type Parameter Cable SA2103 SB214SA RS232 on the CPU unit RS232 Setting Bit Address Word Address Format Notes LD 0~3 D R/W Linear Acceleration(LA) ----------- LA 0~3 D R/W Linear Velocity(LV) ------ LV 0~3 D R/W Next trgt Abs Pos(AP) ------ AP 0~3 D R/W Next Motion Mode(MM) ------ MM 0~3 D R/W Functions Avail.(FA.1) ------ FA.
6 Communication settings and guide of HMI connecting with controller 1. LD、LA、LV、AP、MM、FA.1、AO、UI、LI、PG Main address:Axis parameter number(X、Y、Z、T) 2. MO、B(Operating instructions) Main address:Axis parameter number(X、Y、Z、T) 3. CLEAR、RESET(Operating instructions) Cable Diagram RS232 communication cable HMI terminal 9pin D-SUB female/male Controller terminal 9 pin D-SUB (male) com0/com1 com2 2 RX 7 RX 3 TX 8 TX 5 GND 5 GND 3 TXD 2 RXD 5 GND 6.
6 Communication settings and guide of HMI connecting with controller Note:a. To allow the “Check Code”; b. Direct online simulation disables. ADAM-4015 default communication: 9600, 8, none, 1; station: 1 Note: PLC station must match with the ADAM-4015 configuration. PLC Connect “INIT” with “GND”, and reset the device, then set the communication of ADMA-4015.
6 Communication settings and guide of HMI connecting with controller Set OK, then Update.
6 Communication settings and guide of HMI connecting with controller 255(FF):0-7 channel show. 127(7F):0-6 channel show, 7 Channel does not show. ADAM-4015 Device Bit Address Word Address Format Notes Channel ------ Channel 0-5 D Floating Note: Channel 0-5 data type is floating. Cable Diagram HMI terminal 9pin D-SUB female/male Controller RS485 terminal com0/com1 1 RX- DATA- 6 RX+ DATA+ 6.
6 Communication settings and guide of HMI connecting with controller Supported Device Device Bit Address Word Address Format Notes control CTL (0~5)&128&150 ------ DDD Write only set ------ SET (0~51)&128 DDD state ------ STATUS 0.0~17.2 DD.D Read only Cable Diagram 6.
6 Communication settings and guide of HMI connecting with controller Communication Setting PLC software setting Use the guide of the Workbench software - 37 -
6 Communication settings and guide of HMI connecting with controller Supported Device (Only data of comms can be monitored, some address greater than or equal to 100 are read only. Please pay attention to matching the controller software configuration.
6 Communication settings and guide of HMI connecting with controller 6.
6 Communication settings and guide of HMI connecting with controller Cable Diagram Connect the scanner and the COM port of HMI directly. 6.
6 Communication settings and guide of HMI connecting with controller Cable Diagram RS485-4 communication cable HMI terminal 9pin D-SUB female\male Controller terminal 9 pin D-SUB (male) com0/com1 9 TXD+ 4 TXD6 RXD+ 1 RXD5 GND 6 RXD+ 5 RXD9 TXD+ 1 TXD3 GND 6.
6 Communication settings and guide of HMI connecting with controller Start/Stop STW0~3 ------ D Set frequency ------ HSW 0 D Basic Function Block ------ B 0~41 DD Deviation alarm ------ E 0~41 DD ------ P 0~37 DD High function array ------ H 0~38 DD D array ------ D 0~6 D Programmable control function array STW0 open, start. STW0 close, stop. STW1 close, positive rotation. STW1 open, negative rotation. STW2 REV inching turning. STW3 FWD inching turning. B16 acceleration time.
6 Communication settings and guide of HMI connecting with controller L20 Communication Setting PPC-R communication setting RS232 communication: 19200, 8, even, 1; station number: 128 RS485 communication Note: To communicate with the touch screen, declare variable firstly in the Rexroth software. L40 communication settings Default communication: 38400, 8, 1, none; Station No.
6 Communication settings and guide of HMI connecting with controller Note: To communicate with the touch screen, declare variable firstly in the Rexroth software. L40 Hardware Settings PLC Software Settings PPC-R software setting PLC connects with PC via crossover ethernet cable.
6 Communication settings and guide of HMI connecting with controller 1. Click”scp configurator”--->”scanning ”or” add device”--->”next”, pay attention to the default controller IP: 192.168.1.1. And set IP 192.168.1.1 in the software (PC and controller must be set up in the same segment), ping IP address is OK, that configuration is successful. Save and close “scp configurator”--->”refresh” to see logical devices created in configured logical devices”, double-click to enter.
6 Communication settings and guide of HMI connecting with controller 4. Click “online/login” L40 software setting 1) The IndraLogic software connect with the Rexroth IndraControl L40 by ethernet cable(test: plc IP address:192.168.100.
6 Communication settings and guide of HMI connecting with controller Note:Must select Download symbol file Click “OK” and pop-up the window as follows: And then edit program: Input B0 and pop-up the dialog, configurations as follows, click “OK”: - 47 -
6 Communication settings and guide of HMI connecting with controller And set up coil: At the same time, you will find that there automatically generate two variables in the global variable: Then setting as follows: - 48 -
6 Communication settings and guide of HMI connecting with controller Setting communication parameter: Then click “Login”: Communicating successfully, you can operate(“Online” menu to select “run” or others): - 49 -
6 Communication settings and guide of HMI connecting with controller Note:The PLC panel must be set up, press” Enter”, then press”△”, until showed up “ RS232”, and then press ”Enter” to enter “COM SERV” interfaces (not SERV, it must change to SERV) In accordance with the above settings, the serial line access, Kinco HMIware can be communicated with the Rexroth Controller L40 by serial port.
6 Communication settings and guide of HMI connecting with controller L40 communication cable 6.
6 Communication settings and guide of HMI connecting with controller ※PLC Attribute (station disable) ※Network configuration(Note: PLC port num. must be set 6042,HMI port num. is optional,default is 6042. In addition, the screen and plc must be set in the same network segment, the gateway of the screen is better to set with the actual use of the network gateway .
6 Communication settings and guide of HMI connecting with controller Note: To communicate with the touch screen, declare variable firstly in the Rexroth software. PLC software setting PLC connect with PC by crossover network cable,if using cross-connection network cable, you must add a HUB (we usually use a cross-connection line to access the Internet) 1.
6 Communication settings and guide of HMI connecting with controller 2. “resource”--->“Global variables”--->declare variable in “HMI” 3.
6 Communication settings and guide of HMI connecting with controller b. crossover network cable diagram: HMI Ethernet terminal RJ45 1 TX+ Ethernet Hub or Switch RJ45 (orange,white) 1 RX+(orange,white) 2 RX- (orange) 3 TX+ (green,white) 4 BD4+ (blue) 5 BD4- (blue,white) 6 TX(green) 7 BD3(brown,white) 8 BD3- (brown) 2 TX- (orange) 3 RX+ (green,white) 4 BD4+ (blue) 5 BD4- (blue,white) 6 RX(green) 7 BD3+ (brown,white) 8 BD3(brown) 6.
6 Communication settings and guide of HMI connecting with controller HMI Note: Baud Rate and Station No. must be the same as the setting in the controller. Parameters Setting 1. Predefined PDO mapping parameters a. Default is “yes”, that is an effective predefined PDO mapping parameters.
6 Communication settings and guide of HMI connecting with controller the PDO. b. If the "No", the main station or other equipment necessary to configure the PDO communication parameters and mapping (configure only in the pre-operational status). After configured, you can send a save command via USB-CAN or controller to save the current configuration (restart still valid).
6 Communication settings and guide of HMI connecting with controller 2. Copy “MT5020.EDS” to “C:\Program Files\Common Files\CAA -Targets\ StepServo\ PlcConf” 3. Configuration setting a. run codesys software,make a new project b.
6 Communication settings and guide of HMI connecting with controller c. set Baud Rate d. choose “CanMaster” right click “Append HMI-MT5020” e. Node ID: set slave station No.
6 Communication settings and guide of HMI connecting with controller f. in the “Library Manager” we import “3S_CANopenMaster.lib” g.
6 Communication settings and guide of HMI connecting with controller h. define Global Variable i.
6 Communication settings and guide of HMI connecting with controller j.
6 Communication settings and guide of HMI connecting with controller 6.
6 Communication settings and guide of HMI connecting with controller Note:Change the value of 8-30 to 2 on the Danfoss inverter for modbus protocol(Change the value of 8-30 to 0 for the Danfoss Protocol) Inverter 8-3* FC Port Setting 8-30 protocol *[0] FC (danfoss protocol) [2] Modbus (modbus protocol) 8-31 address 1 – 247 * 1 (HMI station No.
6 Communication settings and guide of HMI connecting with controller RAM Register(Double Word) ———— RMD0-7998.99999 DDDD.DDDDD RAM Register ———— RMW0-7998.99999 DDDD.DDDDD Note: 1. D indicates decimal; the prefix of RMD\RMW\EPD\EPW is address parameter, the suffix is index number. 2. Mapping of index address (adding radix point if having index address, index value follow radix point. Otherwise there’s no radix point): RMW310.1 is to 3-10, please clicking Menu, to find 3-10 to check. 3.
6 Communication settings and guide of HMI connecting with controller ◆Control word RW1: While RW1=0x47C or 1148, it means start. While RW=0x0F03 or 3843, it means stop. ◆Frequency of RW0 mapping : If input 2000 to RW0, frequency is 25HZ, and input 4000, frequency is 50HZ, and so on. ◆Timer, send value of RW1 and RW0 to RWD8000.
6 Communication settings and guide of HMI connecting with controller Input bit (read only) 1X1-65535 ------ DDDDD Input Register (read only) ------ 3X1-65535 DDDDD Output Register ------ 4X1-65535 DDDDD Note: Mapping of address (same as *10 relationships): 2-01 is to 4X2010 3-02 is to 4X3020 So address 4X1300 is to 1-30 as following picture, here is double word address. To get more information, please refer to danfoss manual.
6 Communication settings and guide of HMI connecting with controller Set 0X 3,0X 4,0X 5,0X 6,0X 7 all to “1” via the method of setting on when window open; Change the inverter status (start or stop) by control the status of 0X11. 0x2000=0010 0000 0000 0000(binary bit from the 17th to the 32nd), setting the 30th bit to “1” means frequency is 25Hz, and “1” in the 29th bit means 12.5Hz, and so on. In short, the 0X17~0X32 is to control frequency. The inverter will show the value after starting.
6 Communication settings and guide of HMI connecting with controller 6.
6 Communication settings and guide of HMI connecting with controller Note: RS485 communication, we should change the value of D1120 in the PLC Software. PLC setting 1. Wpl207->Auxiliary Editing->RS-485 Protocol Setting (D1120), you can set the value of D1120. 2. PLC connection with the Wpl207, monitoring changes in the value of D1120. for example, 9600, 7, even, 1.
6 Communication settings and guide of HMI connecting with controller Step Relay S0-9999 ------ DDDD Timer Relay T0-9999 ------ DDDD Counter Relay C0-9999 ------ DDDD Timer ------ TV0-9999 DDDD Counter ------ CV0-127 DDD Double word counter ------ CV2 232-255 DDD Data Register ------ D0-9999 DDDD Cable Diagram DVP RS232 communication cable DVP RS485-2 communication cable 6.
6 Communication settings and guide of HMI connecting with controller Communication Setting RS485-2 communication Note: Only use 4X, not 3X in the ev5000 project. Supported Device Device Bit Address Word Address Format Output bit 0X1-65535 ------ DDDDD Input bit (read only) 1X1-65535 ------ DDDDD Input Register (read only) ------ 3X1-65535 DDDDD Output Register ------ 4X1-65535 DDDDD Controller Setting 1.
6 Communication settings and guide of HMI connecting with controller 2. Communication parameters and notes DTA4848:Address and Content of Word Register (corresponds to 4X in the HMI) Address Content 4700H Process value (PV) 4701H Set point (SV) 4702H Upper-limit alarm 1 Explanations In the running mode , when ALA1 is 1 and Upper-limit alarm is valid. 4703H Lower-limit alarm 1 In the running mode , when ALA1 is 1 and Lower -limit alarm is valid.
6 Communication settings and guide of HMI connecting with controller Please refer to the contents of the “Alarm Outputs” for detail. 4715H Alarm 1 type In the setting mode Please refer to the contents of the “Alarm Outputs” for detail. 4716H Alarm 2 type In the setting mode 4717H Temperature selection unit 4718H Heating/Cooling Selection 4719H Control Run/Stop setting 471AH Communication selection display control o C : 1 (default), oF : 0.
6 Communication settings and guide of HMI connecting with controller 0 ~ 99, 0:0.5 sec. in the adjusting mode or 1007H 1st group of Heating/Cooling control cycle 1008H 2nd group of Heating/Cooling control cycle 0 ~ 99, 0:0.5 sec. in the adjusting mode 1009H PB Proportional band 0.1 ~ 999.9. in the adjusting mode 100AH Ti Integral time 0~9999. in the adjusting mode 100BH Td Derivative time 0~9999. in the adjusting mode 100CH Integration default 0 ~ 100%, unit is 0.1%.
6 Communication settings and guide of HMI connecting with controller 1019H Dead Band setting of valve 0 ~ 100%; unit: 0.1%. in the adjusting mode 101AH Upper-limit of feedback signal set by valve 0~1024. in the adjusting mode 101BH Lower-limit of feedback signal set by valve 0~1024. in the adjusting mode 101CH PID parameter selection 0~4. in the adjusting mode 101DH SV value corresponded to PID value Only valid within available range, unit: 0.1 scale.
6 Communication settings and guide of HMI connecting with controller under the control of PID and the mode of 1040H~ 1047H Actual step number setting inside the correspond pattern 1050H~ 1057H Cycle number for repeating the execution of the correspond pattern 1060H~ 1067H Link pattern number setting of the correspond pattern ) 0 ~ 7 = N, indicate that this pattern is executed from step 0 to step N. in the setting mode 0 ~ 99 indicate that this pattern has been executed for 1 ~ 100 times.
6 Communication settings and guide of HMI connecting with controller 3. Communication Parameters List Communication protocol: Modbus (ASCII); Available communication address: 1 to 255, 0 is broadcast address Function code: 03H: read the contents of register (Max. 3 words). 06H: write 1 (one) word into register. Cable Diagram DVP RS485-2 communication cable 6.
6 Communication settings and guide of HMI connecting with controller Note: Communication parameter must the same as the controller panel.
6 Communication settings and guide of HMI connecting with controller Supported Device EB-MOD2P-01 Device Bit Address Word Address Format Internal/External Output bit 0X1-60 ------ DDDDD Internal/External Input bit 1X1-60 ------ DDDDD Data Register bit 3X_bit1-60 ------ DDDDD Data Register bit 4X_bit1-60 ------ DDDDD Simulate Input Register bit ------ 3X1-60 DDDDD Data Register ------ 4X1-60 DDDDD Data Register ------ 5X1-60 DDDDD Data Register ------ 6X1-60 DDDDD Data Re
6 Communication settings and guide of HMI connecting with controller After installation, you can find the appropriate symbol in "PROFIBUS DP\GATWAY". Project configuration (1)Use the guide to set up projects in the s7-300 software. (2)Double click “DP” of "HW Config"->attribute->new (3)After press “ok”, and then give a connection as follows: Note: the address of DP can’t be the same as MPI’s. Double click the address number to change. (4)Double click “GATEWAY"->"eview"->"B_MO1"to extend device.
6 Communication settings and guide of HMI connecting with controller Note: for project configuration of BRIDGE, you must configure DI/D0 resource of 12 bytes firstly. AI/AO is optional. (5)Must Use OB82,OB86,OB100,OB121,OB122 in the ladder program of the external device, otherwise you need to manually operate the RUN switch of the external device as “RUN,STOP,RUN” in this order upon restart the display or PLC.
6 Communication settings and guide of HMI connecting with controller ON OFF ON 38400 OFF ON ON 57600 ON ON ON 115200 (5)Setting station number of modbus by switching DIP4-8 of modbus ID port ,support 1 to 30 kinds of station number(DIP4 is lowest bit,DIP8 is highest bit, if DIP4 is on and DIP5~8 is off, it means station number is 00001,that is No. 1 station).
6 Communication settings and guide of HMI connecting with controller Series ENDA devices CPU Link Module Driver ELC RS485-2 on the CPU unit ETC RS485-2 on the CPU unit EUC RS485-2 on the CPU unit EPC RS485-2 on the CPU unit EDP RS485-2 on the CPU unit ENDA Controller/PLC Devices System configuration Series ENDA devices CPU Link Module COMM Type ELC RS485-2 on the CPU unit RS485 ETC RS485-2 on the CPU unit RS485 EUC RS485-2 on the CPU unit RS485 EPC RS485-2 on the CPU unit RS
6 Communication settings and guide of HMI connecting with controller Coils Coils 0-65535 ------ DDDDD Discrete input (read only) DI 0-65535 ------ DDDDD Holding Registers ------ HR 0-65535 DDDDD Input Register (read only) ------ IR 0-65535 DDDDD Cable Diagram RS485 communication cable HMI terminal 9pin D-SUB female\male Controller RS485 terminal com0/com1 1RX6RX+ 5 GND B A GND 6.
6 Communication settings and guide of HMI connecting with controller Emerson Ec20 RS232 communication Emerson Ec10 RS485-2 communication Emerson Ec20 RS485-2 communication - 86 -
6 Communication settings and guide of HMI connecting with controller Note: Communication with port1, you must set the system configuration in the programming software first.
6 Communication settings and guide of HMI connecting with controller Emerson Ec10 Device Bit Address Word Address Format Output Relay X000-377 ------ OOO Input Relay Y000-377 ------ OOO Internal Relay M0000-1999 ------ DDDD Special Relay SM000-255 ------ DDD Step Relay S000-991 ------ DDD Timer Relay T000-255 ------ DDD Counter Relay C000-255 DDD DDDD Data register ------ -----D0000-7999 Special Register ------ SD000-255 DDD Index Register ------ Z00-15 DD Timer -
6 Communication settings and guide of HMI connecting with controller Emerson RS485-2 communication 6.
6 Communication settings and guide of HMI connecting with controller Supported Device Device Bit Address Word Address Format UPSSet UPSSet1-6 ------ DDDDD UPSPanel UPSPanel0-9 ------ DDDDD UPSData ------ UPSData0-70 DDDD UPSDisp ------ UPSDisp0 DDDDD UPSCommand ------ UPSCommand0-52 DDDDD UPSText ------ UPSText0-1 DDDDD - 90 - Notes
6 Communication settings and guide of HMI connecting with controller Slave driver notes: 1. Transmit the device value to LW, LB by timer; refer to the addr table for details. 2. UPSCommand must use with UPSSet、macro; 3. UPSDisp must use with UPStexr、UPSPanel、macro. Epower HMI project notes: 1. The project must have UPSData0 device, otherwise the data accuracy will be affected; Suggest to put UPSData0 device in the public window. 2. LW.
6 Communication settings and guide of HMI connecting with controller Device Bit Address Word Address Format B0 - 8999 ------ DDDD ------ W0 - 8999 DDDD Communication Setting EVIEW MASTER EVIEW SLAVE Cable Diagram - 92 - Notes
6 Communication settings and guide of HMI connecting with controller 6.
6 Communication settings and guide of HMI connecting with controller FBS-CB25-3 module RS485 communication FBS-CB25-3 module communication Modbus RTU RS232 communication Modbus RTU RS485-2 communication - 94 -
6 Communication settings and guide of HMI connecting with controller Note: The detailed communication configuration must be the same as the PLC’s port setting.
6 Communication settings and guide of HMI connecting with controller HMI terminal 9pin D-SUB female/male Controller terminal 15 pin D-SUB (male) com0/com1 com2 2 RX 7 RX 2 TXD 3 TX 8 TX 1 RXD 5 GND 5 GND 6 GND 3 RTS 4 CTS FBS-CB25-3 module communication RS232 communication cable HMI terminal 9pin D-SUB female/male Controller port1 terminal 9 pin D-SUB (male) com0/com1 2RXD 3TXD 5GND 7RTS 8CTS 2TXD 3RXD 5SG 7CTS 8RTS RS485 communication cable 6.
6 Communication settings and guide of HMI connecting with controller NB NB2U24R-11 RS485 interface on the CPU System configuration Series CPU Link Module Ethernet Type Parameter Cable SPB NB NW0P20T-31 NB2U24R-11 RS485 interface on the CPU RS485 interface on the CPU RS485-4 RS485-4 Setting Your owner cable Communication Setting Note:When PLC is protected by password, protocol time out 2 is 65535, and the register is read only.
6 Communication settings and guide of HMI connecting with controller DW 0~6FF HHH Special register ----------- DW_special 0~1FF HHH Link register(0 slot) ------ W0 0~7FF HH Link register(1 slot) ------ W1 0~7FF HHH Link register(2 slot) ------ W2 0~7FF HHH Link register(3 slot) ------ W3 0~7FF HHH Link register(4 slot) ------ W4 0~7FF HHH Link register(5 slot) ------ W5 0~7FF HHH Link register(6 slot) ------ W6 0~7FF HHH -----Link register(7 slot) W7 0~7FF Note:M_special a
6 Communication settings and guide of HMI connecting with controller 6.23 GE Fanuc Automation Inc.
6 Communication settings and guide of HMI connecting with controller VersaMax Micro & Nano Series IC200UAL004/005/006 IC200UDD110/120/212 IC200UDR005/006/010 IC200UAA007 IC200UAR028 RS232 on port1 RS485 on port2 Network communication Series Series 90-30 Series 90-70 CPU Link Module Driver CPU311 CPU313 CPU323 CPU331 CPU340 CPU341 CPU350 CPU351 CPU352 CPU360 CPU363 CSE311 CSE313 CSE323 CSE331 CSE340 IC693CMM321 Modbus TCP CPU364 CPU374 Ethernet interface on CPU CPU731 CPU771 CPU772 CPU780 CPU
6 Communication settings and guide of HMI connecting with controller CPX935 CGR772 CGR935 PACSystem RX7i CPE010 CPE020 CRE020 Ethernet interface on CPU Serial System configuration Series CPU Link Module COMM Type Parameter Cable RS232 Setting Your owner cable RS485-4 Setting Your owner cable RS232 Setting Your owner cable RS485-4 Setting Your owner cable RS232 on port1 RS232 Setting Your owner cable RS485 on port2 RS485-4 Setting Your owner cable RS232 on port1 RS232 Setting
6 Communication settings and guide of HMI connecting with controller CSE323 CSE331 CSE340 CPU364 CPU374 Ethernet CPU interface Series 90-70 CPU731 CPU771 CPU772 CPU780 CPU781 CPU782 CPU788 CPU789 CPM790 CPM915 CPM925 CSE784 CSE924 CSE925 CPX772 CPX782 CPX928 CPX935 CGR772 CGR935 IC697CMM742 (Type2) PACSystem RX7i CPE010 CPE020 CRE020 Ethernet CPU interface on on Serial Communication Setting GE Fanuc Series SNP RS232 Communication - 102 -
6 Communication settings and guide of HMI connecting with controller GE Fanuc Series SNP RS422 Communication GE SNP-X Protocol RS232 Communication GE SNP-X Protocol RS422 Communication - 103 -
6 Communication settings and guide of HMI connecting with controller Note: Set matching communication parameter in the Programming software.
6 Communication settings and guide of HMI connecting with controller Supported Device Device Bit Address Word Address Format System SC01-32 ------ DD System SB01-32 ------ DD System SA01-32 ------ DD System S01-32 ------ DD Temporary T001-256 ------ DDD Internal M0001-4096 ------ DDDD Genius Global G0001-1280 ------ DDDD Output Q0001-2048 ------ DDDD Input I001-256 ------ DDD Analog Output ------ AQ001-512 DDD Analog Input ------ AI0001-2048 DDDD Register --
6 Communication settings and guide of HMI connecting with controller Cable Diagram GE Fanuc Series SNP RS232 communication The communication cable recommended by GE Fanuc Automation VersaMax series RS232 communication HMI terminal 9pin D-SUB female/male Controller VersaMax terminal 9 pin D-SUB (male) com0/com1 com2 2 RX 7 RX 3 TX 8 TX 2 TX 3 RX 5 GND 5 GND 5 GND VersaMax Micro & Nano Series RS232 communication CMM311 RS232 communication CMM311 RS422 communication - 106 -
6 Communication settings and guide of HMI connecting with controller HMI terminal 9pin D-SUB female/male CMM311 port2 terminal 25 pin D-SUB (male) com0/com1 1 Rx6 Rx+ 5 GND 4Tx9 Tx+ 9 SDA 21 SDB 7 GND 13 RDA 25 RDB 10 RTSA 11 CTSA 12 TER CTS 22 RTSB 23 CTSB 90-30/VersaMax RS422 communication Ethernet communication protocol cable Cross-connection or crossover network cable can be used as communication cable via the hub a. Cross-connection cable diagram: b.
6 Communication settings and guide of HMI connecting with controller HMI Ethernet terminal RJ45 1 TX+ Ethernet Hub or Switch RJ45 (orange,white) 1 RX+(orange,white) 2 RX- (orange) 3 TX+ (green,white) 4 BD4+ (blue) 5 BD4- (blue,white) 6 TX(green) 7 BD3(brown,white) 8 BD3- (brown) 2 TX- (orange) 3 RX+ (green,white) 4 BD4+ (blue) 5 BD4- (blue,white) 6 RX(green) 7 BD3+ (brown,white) 8 BD3(brown) 6.
6 Communication settings and guide of HMI connecting with controller Haiwell RS485 communication Supported Device Device Bit Address Word Address Format Special memory Relay SM0–215 ------- DDD Counter Relay C0–127 ------- DDD Timer Relay T0–127 ------- DDD Internal Relay M0–2047 ------- DDDD Switch Output Y0–127 ------- DDD Switch Input ------- DDD System register X0–127 ------- SV0-139 DDD Counter(Current Value) ------- CCV-16 0-47&80-127 DDD Counter(Current Value doub
6 Communication settings and guide of HMI connecting with controller Haiwell RS485 communication cable 6.
6 Communication settings and guide of HMI connecting with controller Meter Number ------ ANUM C032 HHHH.H Init Meter ------ ASTR 0 H Register value ------ AMVD 9010 HHHH Note:Use text part to show meter number (ANUM). AMVD data type: signed integer Cable Diagram HMI terminal 9pin D-SUB female/male Controller RS485 terminal com0/com1 1RX- 10 B 6RX+ 10 A 6.
6 Communication settings and guide of HMI connecting with controller Inverter internal setting Code Name description A001 Frequency set 00(VR)/01(Terminal)/02(operator)/03(RS485)/04(OPT 1)/05(OPT 2) A002 Run set 01(Terminal)/02(operator)/03(RS485) /04(OPT 1)/05(OPT 2) C71 Baudrate 02(close loop detect)/ 03(2400bps)/ 04(4800bps)/ 05(9600bps)/ 06(19200bps) C72 Station set 1~32 C73 Data bit 7(7 bit)/8(8 bit) C74 Parity 00(none)/01(even)/02(odd) C75 Stop bit 1(bit)/2(bit) Note:A001, A00
6 Communication settings and guide of HMI connecting with controller 6.27 Hitachi IES Co.
6 Communication settings and guide of HMI connecting with controller MICRO-EH EH-150(EH-CPU548) Port 2 on EH-SIO MICRO-EH(EH-D10) MICRO-EH(EH-A14) MICRO-EH(EH-D14) MICRO-EH(EH-A23) MICRO-EH(EH-D23) MICRO-EH(EH-A28) MICRO-EH(EH-D28) Port 1 on CPU MICRO-EH(EH-A23) MICRO-EH(EH-D23) MICRO-EH(EH-A28) MICRO-EH(EH-D28) Port 2 on CPU MICRO-EH(EH-A64) MICRO-EH(EH-D64) MICRO-EH(EH-A40) MICRO-EH(EH-D40) MICRO-EH(EH-A20) MICRO-EH(EH-D20) Port on CPU EH-OB232
6 Communication settings and guide of HMI connecting with controller RS422 communication Supported Device Hitachi EH-A23DR Device Bit Address Word Address Format Notes External Input X 00.000-5A.095 ------ HHH.DDD Read Only External Output Y 00.000-5A.095 ------ HHH.DDD Remote Input X 100.000-9FF.095 ------ HHH.DDD Remote Output Y 100.000-9FF.095 ------ HHH.
6 Communication settings and guide of HMI connecting with controller Remote Input ------ WX 100.00-9FF.09 HHH.DD Remote Output ------ WY 100.00-9FF.09 HHH.DD Word Internal Output ------ WR 0000-C3FF HHHH Special Word Output ------ WRF 000-FFFF HHHH Data Area ------ WM 0000- FFFF HHHH First CPU Link ------ WL 0000-03FF HHHH Second CPU Link ------ WL 1000-FFFF HHHH Read Only TC 00000-65535 DDDDD Timer Counter -----Note:X0.015 in the HMI match x15 in the PLC,Y1.
6 Communication settings and guide of HMI connecting with controller o SW1 on is 19200 bps Which procedure(1 or2) to use by judging the value of the WR F01A.Different with EH150, The highest bit of WR F01A is optional, The data will reset when turn on the power again. If the value of R 7F6 is set on, the data of WR F01A will be stored in Flash memory. o 0x0000 for procedure 1. o 0x8000 for procedure 2.
6 Communication settings and guide of HMI connecting with controller 6.
6 Communication settings and guide of HMI connecting with controller RS485 网口通讯参数设置 - 119 -
6 Communication settings and guide of HMI connecting with controller 注意:需在 plc 编程软件中设置站号 Supported Device LM 系列 Device Bit Address Word Address Format Discrete inputs and image Relay I0.0-2.7 ------ D.O Discrete outputs and image Relay Q0.0-1.7 ------ D.O M100.0-7816.7 ------ DDDD.
6 Communication settings and guide of HMI connecting with controller Cable Diagram Hollysys LM RS232 communication cable Hollysys LM RS485 communication cable 网口通讯协议 Ethernet 通讯线 PLC 直接与 HMI 连,用交叉网线;经 hub 或 switch 通讯,直连或交叉网线均可。 a. 交叉网线接线图: b.
6 Communication settings and guide of HMI connecting with controller 6.
6 Communication settings and guide of HMI connecting with controller Supported Device Device Bit Address Word Address Format ------ DDDD HMI Internal register LB 0-4095 ------ LW 0-4094 DDDD MCU Register ------ VB 0-4095 DDDD MCU Register ------ VW 0-4094 DDDD HMI Internal Relay Cable Diagram RS232 Port RS485 Port - 123 - Notes
6 Communication settings and guide of HMI connecting with controller 6.30 IDEC Corporation Serial Communication Series CPU Link Module Driver MICRO SMART FC4A-C10R2 RS232 on the CPU unit IDEC MicroSmart System configuration Series CPU Link Module COMM Type MICRO SMART FC4A-C10R2 RS232 on the CPU unit RS232 Parameter Setting Cable Your owner cable Supported Device Device Bit Address Word Address Format Internal Relay M0.0-127.7 ------ DDD.O Output Q0.0-30.7 ------ DD.
6 Communication settings and guide of HMI connecting with controller Cable Diagram Idec RS232 communication cable HMI terminal 9pin D-SUB female/male com0/com1 1 RX6 RX+ 8 3 TXD 2 RXD 4 TX5 GND Controller terminal 8 pin Mini Din (male) 2 1 4 RXD 3 TXD 5 6 GND 7 6.31 Inovance Electric Corporation Serial Communication Series CPU Link Module Driver CPU direct H2U H2U-3624MR Inovance H2u(don’t support multi station) COM1 CPU direct Modbus RTU*1 COM1 Note: 1. Don’t hot plug! 2.
6 Communication settings and guide of HMI connecting with controller RS422 RS485 PLC setting - 126 -
6 Communication settings and guide of HMI connecting with controller You should put off JP0, if communication on the COM0, RS485. You should set D8126=01h, if communication on the COM1, RS485. MODBUS-RTU Slave protocol RS485 communication parameter: PLC COM0 port is controlled by D8110; COM1 port is controlled by D8120. PLC setting COM0 setting: D8116=02h, modbus-RTU slave protocol; D8111=1, station: 1; D8110=81h, communication parameter: 9600, 8, none, 1.
6 Communication settings and guide of HMI connecting with controller Supported Device Device Bit Address Word Address Format Input Relay X 000-177 ------ OOO Output Relay Y 000-177 ------ OOO Auxiliary Relay M 0000-1535 ------ DDDD Timer Relay T_bit 000-255 ------ DDD Counter Relay C_bit 000-255 ------ DDD Data Register Relay SM 8000-8255 ------ DDDD S 000-999 ------ DDD Status Relay Timer ------ T 000-255 DDD Counter ------ C 000-199 DDD Data register ------ D 0000
6 Communication settings and guide of HMI connecting with controller Note: put off JP0 by RS485. COM1 port communication cable 6.
6 Communication settings and guide of HMI connecting with controller Cable Diagram RS232 communication cable RS485 communication cable 6.
6 Communication settings and guide of HMI connecting with controller Series CPU KINCO K306-24AR Link Module COMM Type Parameter Cable RS232 on the CPU unit RS232 Setting Your owner cable RS485 on the port RS485 Setting Your owner cable Supported Device KINCO Device Bit Address Word Address Format Discrete inputs and image Relay I0.0-31.7 ------ D.O Discrete outputs and image Relay Q0.0-31.7 ------ D.O Internal memory Relay M0.0-31.7 ------ DD.
6 Communication settings and guide of HMI connecting with controller Cable Diagram RS232 communication cable RS485 communication cable 6.
6 Communication settings and guide of HMI connecting with controller ECOVARIO ECOVARIO CD CD420 CD430 CD620 RS232 on the CPU unit RS485 on port RS232 on the CPU unit System configuration Series CPU ED100 ED ED200 ECOVARIO ECOVARIO CD CD420 CD430 CD620 Link Module COMM Type Parameter Cable RS232 on the CPU unit RS232 Setting Your owner cable RS485 on port RS485-2 Setting Your owner cable RS232 on the CPU unit RS232 Setting Your owner cable RS485 on port RS485-2 Setting Your own
6 Communication settings and guide of HMI connecting with controller Supported Device Device Bit Address Word Address Range word ———— 20 Refer to the kinco manual word ———— 10 Refer to the kinco manual word ———— 8 Refer to the kinco manual Notes Note: Use the touch screen, pay attention to the rules addressing. The specific reference to the following description. Touch-screen type of address: according to the number of bits to the servo. Can only be 20, 10, 8.
6 Communication settings and guide of HMI connecting with controller RS485 communication cable 6.
6 Communication settings and guide of HMI connecting with controller Serial Communication Setting KV-16DT KV-1000 KV-3000 default communication: 9600, 8, 1, even; station: 0(Don’t support station No.
6 Communication settings and guide of HMI connecting with controller Network Communication Setting HMI PLC configuration 1.
6 Communication settings and guide of HMI connecting with controller 2. Switch to the "Monitor" window to see the changes of the figure will pop up window, Click [PLC transfer -> Monitor mode (T)], pop-up "transmission program [communication goals: KV-5000 path: USB]", Click [implementation], content writing, once again view the "[0] KV-5000 R30000" in the PLC's IP address in the "Monitor" window [unit configuration], This indicates that the address has been modified over.
6 Communication settings and guide of HMI connecting with controller Device Bit Address Word Address Format Counter_contact0- 59915 ------ DDDDD Timer_contact0- 65535 ------ DDDDD High speed counter CTH_contact0- 511 ------ DDD High speed counter Comparator CTC_contact0- 511 ------ DDD ------ DDDDD Counter current Relay0- 32766 ------ Counter_current0- 3915 DDDD Counter preset ------ Counter_preset0- 65535 DDDDD Timer current ------ Timer_current0- 65534 DDDDD Timer preset
6 Communication settings and guide of HMI connecting with controller Temporary data memory ------ TM0-511 DDD Extended Data memory ------ EM0-65534 DDDDD -----FM0-32767 DDDDD Extended Data memory Note: PLC bit address without a decimal point in the distinction, in fact, the last two addresses corresponding to the fractional part, makes a distinction between the touch screen. Example, PLC which corresponds to R009, the touch screen address is R0.
6 Communication settings and guide of HMI connecting with controller Cable Diagram KV RS232 communication cable Ethernet communication protocol cable Cross-connection or crossover network cable can be used as communication cable via the hub or switch a. Cross-connection cable diagram b.
6 Communication settings and guide of HMI connecting with controller 6.
6 Communication settings and guide of HMI connecting with controller Communication Setting KOYO series RS232 communication setting KOYO series RS485 communication setting KOYO DL06 series RS422 communication setting - 143 -
6 Communication settings and guide of HMI connecting with controller Cable Diagram KOYO SM24-T series RS232 communication cable KOYO SM24-T series RS485 communication cable KOYO DL06 series RS232 communication cable - 144 -
6 Communication settings and guide of HMI connecting with controller HMI terminal 9pin D-SUB female/male Controller PORT2 15 pin SVGA terminal (male) com0/com1 com2 8 TX 3 TX 2 RX 7 RX 5 GND 5 GND 3 RX 2 TX 7 GND 4 RTS 5 CTS KOYO DL06 series RS422 communication cable 6.
6 Communication settings and guide of HMI connecting with controller COM COM2023 RS232 on CPU unit RS232 Setting Your owner cable RS485 on CPU unit RS485-2 Setting Your owner cable Supported Device Please refer to the PLC manual for details. Communication Setting Ktc RS232 communication Ktc RS485-2 communication Note: Must modify communication parameter in the programming software.
6 Communication settings and guide of HMI connecting with controller KTC RS232 communication cable Direct connect (cable by KTC Corporation) KTC RS485 communication cable 6.
6 Communication settings and guide of HMI connecting with controller Supported Device Device Bit Address Word Address Format Group close instruction LB0 ------ DD Remote valve open operation LB1 ------ DD Remote valve close operation LB2 ------ DD Remote valve address set operation LB3 ------ DD Set gain cunrrent state LB4 ------ DD flase valve open LB8 ------ DD flase valve close LB9 ------ DD valve open feedback LB10 ------ DD valve close feedback LB11 ------ DD va
6 Communication settings and guide of HMI connecting with controller valve hypopiesis alarm LB30 ------ DD Show current valve state LB31 ------ DD Cable Diagram RS232 6.
6 Communication settings and guide of HMI connecting with controller Lecom AB RS485 communication Cable Diagram Lecom AB RS232 communication cable Lecom AB RS485 communication cable - 150 -
6 Communication settings and guide of HMI connecting with controller 6.40 LS Industrial Systems Co., Ltd. Serial Communication Series CPU Link Module Driver K120S K7M-DR10UE K7M-DR20U K7M-DT30U K7M-DT40U K7M-DT60U Port1 on CPU unit Port2 on CPU unit LG Master KxxxS LG Master K-Cnet LG Modbus RTU RS232 on the CPU unit LG XGT CPU Serial XGB XBC-DN64H XBC-DR32H RS232 on the channel1 RS485 on the channel2 LG XGT_Cnet Series Note: 1.
6 Communication settings and guide of HMI connecting with controller HMI RS232 communication RS485 communication PLC setting - 152 -
6 Communication settings and guide of HMI connecting with controller If click “Connect+Write+Run+Monitor Start”, it will give a “Cannot Change PLC Mode”. Need to let the run light go out by manual control, and then download. After download, let the run light keep on.
6 Communication settings and guide of HMI connecting with controller PLC LG XGT CPU Serial protocol default communication: 115200, 8, none, 1; station number: 0 Note: Only support 115200 buadrate for the protocol; station number disable.
6 Communication settings and guide of HMI connecting with controller LG XGT_Cnet Series protocol default communication: 9600, 8, none, 1; station number: 0 HMI RS232 RS485 - 155 -
6 Communication settings and guide of HMI connecting with controller XG5000 software setting 1. “Tools”---“Network Manager” set communication 2. Communicating in the OPR mode Supported Device K120S K7M-DR10UE Device Bit Address Word Address Format I/O Relay P0.0-63.f ------ DD.H Auxiliary Relay M0.0-191.f ------ DDD.H Link Relay L0.0-63.f ------ DD.H Keep Relay K0.0-31.f ------ DD.H Special Relay F0.0-31.
6 Communication settings and guide of HMI connecting with controller File Relay R_bit 0.0-10239.F ------ DDDDD.H Data Relay D_bit 0.0-10239.F ------ DDDDD.H Communication Relay N_bit 0.0-5119.F ------ DDDD.H Link Relay L_bit 0.0-2047.F ------ DDDD.H Index Relay Z_bit 0.0-127.F ------ DDD.H Counter Contact Relay C_bit 0-1023 ------ DDDD Timer Contact Relay T_bit 0-1023 ------ DDDD Special Relay F_bit 0.0-1023.F ------ DDDD.H Keep Relay K_bit 0.0-4095.F ------ DDDD.
6 Communication settings and guide of HMI connecting with controller Auxiliary Relay M_bit 0.0-1023.F ------ DDDD.H I/O Relay P_bit 0.0-1023.F ------ DDDD.
6 Communication settings and guide of HMI connecting with controller K120S K-cnet protocol RS485-2 communication cable LG Modbus Rtu protocol RS485-2 communication cable LG XGT CPU Serial protocol RS232 communication cable LG XGT_Cnet Series protocol RS232 programming cable - 159 -
6 Communication settings and guide of HMI connecting with controller RS232 communication cable RS485 communication cable 6.41 LUST Serial Communication Series CPU Link Module Driver CDE34.008 CDE34.008 RS232 on the CPU unit LustBus Network communication (direct online simulation disable) Series CPU Link Module Driver ServoOne junior Lust ETH on the CPU Lust Ethernet Slave Serial System configuration Series CDE34.008 CPU Link Module COM Type CDE34.
6 Communication settings and guide of HMI connecting with controller Lustbus RS232 default communication: 57600, 7, even, 1; station: 1 Network Communication Setting HMI Network configuration - 161 -
6 Communication settings and guide of HMI connecting with controller The way to change IP of Servo drive system Plug the 24-volt power supply on the X2, plug the network cable on the X9.
6 Communication settings and guide of HMI connecting with controller Parameter Initial IP Modified IP b3 b2 b1 b0 int 192 168 39 5 hex C0 A8 27 05 int 192 168 100 240 hex C0 A8 64 F0 b3 b2 b1 b0 int 192 168 39 5 hex C0 A8 27 05 int 192 168 100 240 hex C0 A8 64 F0 Parameter Initial IP Modified IP The following description of specific processes, after the servo power D1 D2 5. 1.
6 Communication settings and guide of HMI connecting with controller D1 D2 l u Press key T2 of about 1s D1 D2 b 0 Press key T2 of about 1s D1 D2 b 0 1s at about T2 button to display the value of d0, the initial value is 05 D1 D2 0 5 Press T1, respectively, and T2, you can adjust the value of b0, After release, while at T1 and T2 key until the display or can be, Then press and T1 and T2, also show b0, then press the key T1 of about 1s,can switch to b2, empathy can be modified the value of b2
6 Communication settings and guide of HMI connecting with controller Supported Device Refer to the Controller software for details: DriveManager for c-line drives ServoOne junior Word Address Format Array_DWord32 0.00000-32767.65535 DDDDD.DDDDD Array_DWord16 0.00000-32767.65535 DDDDD.
6 Communication settings and guide of HMI connecting with controller conversion can be displayed, as should show -3, while the display 253, which can be done in the macro data conversion, so 253-256 = -3, that is in need of special address type conversion . Cable Diagram Lustbus RS232 communication cable Ethernet communication protocol cable Connecting PC and HMI use cross-ruling; use Cross-over cable or cross-ruling via hub or switch. a. cross-ruling cable diagram: b.
6 Communication settings and guide of HMI connecting with controller 6.
6 Communication settings and guide of HMI connecting with controller Tool port on the Control unit RS232C port on the Control unit FP2 FP2SH RS232C Setting AFP2804 RS422(4 wire) Setting Your owner cable AFP2805 RS485(2 wire) Setting Your owner cable RS232C Setting AFP3463 RS422(4 wire) Setting Tool port on the Control unit RS232C AFP2462 Tool port on the Control unit AFP3462 AFPE224300 FP-e RS232C AFPE214325 RS485(2 wire) AFPE214322 FP-X Your owner cable Your owner cable Your owne
6 Communication settings and guide of HMI connecting with controller RS422 communication Supported Device FP0-C16 Device Bit Address Word Address Format Input(X) Relay Y0.0-12.F ------ DD.H Output(Y) Relay X0.0-12.F ------ DD.H Timer(T) Relay T0-99 ------ DD Counter(C) Relay C100-143 ------ DDD Internal Relay(R) R0.0-62.F R900.0-903.F ------ DD.H DDD.
6 Communication settings and guide of HMI connecting with controller Input(X) Relay X0.0~109.F ------ DDD.H Output(Y) Relay Y0.0~109.F ------ DDD.H Timer(T) Relay T0~1007 ------ DDDD Counter(C) Relay C1008~1023 ------ DDDD Link Relay(L) L0.0~127.F ------ DDD.H Internal Relay(R) R0.0~255.F R900.0~911.F ------ DDD.H Timer/Counter set value(SV) ------ EV0~1023 DDDD Timer/Counter elapse value(EV) ------ SV0~1023 DDDD Data Register(DT) ------ DT0~32764 DDDDD Note: 1).
6 Communication settings and guide of HMI connecting with controller Module port: RS485 communication RS422 communication FP3 RS422 programming port: Another module RS422 communication: - 171 -
6 Communication settings and guide of HMI connecting with controller 6.
6 Communication settings and guide of HMI connecting with controller 6.
6 Communication settings and guide of HMI connecting with controller RS485: Supported Device Device Bit Address Word Address Format Notes Register ------ Register 0~23 DD Write only Register ------ Register 24~47 DD Read only Cable Diagram RS232 HMI terminal 9pin D-SUB female/male com1 Controller terminal 9pin D-SUB 2 RX 2 TXD 3 TX 3 RXD 8 5 GND 4 GND 5 GND RS485-2 - 174 -
6 Communication settings and guide of HMI connecting with controller 6.
6 Communication settings and guide of HMI connecting with controller Q02HCPU Q12HCPU Q25HCPU QJ71C24 QJ71C24-R2 QJ71C24N QJ71C24N-R2 QJ71C24N-R4 Mitsubishi Q_QnA (Link Port) Q06HCPU RS232 on the CPU unit Mitsubishi Q06H Note: 1. Don’t hot plug! 2.
6 Communication settings and guide of HMI connecting with controller Fx2N-10GM Fx2N-20GM Fx3uc Q00jCPU Melsec Q Q00CPU Q01CPU Q02CPU Q02HCPU Q06HCPU Q12HCPU Q25HCPU Q06HCPU RS485 Module RS485-4 Setting Your owner cable RS232 on the CPU unit RS232 Setting Your owner cable RS485 on the CPU unit RS485-4 Setting Your owner cable RS232 on the CPU unit RS232 Setting Your owner cable RS485 on the CPU unit RS485-4 Setting Your owner cable RS485 Module RS485-4 Setting Your owner cable R
6 Communication settings and guide of HMI connecting with controller Q04UDHCPU Q06UDHCPU Q13UDHCPU Q26UDHCPU QJ71E71-B5 QJ71E71-100 Serial Communication Setting FX 1s protocol default communication: 9600, 7, even, 1; station: 0 RS232 communication RS422 communication Select default parameter for plc - 178 -
6 Communication settings and guide of HMI connecting with controller FX 2n default communication: 9600, 7, even, 1; station: 0 RS232 communication RS422 communication - 179 -
6 Communication settings and guide of HMI connecting with controller Fx2N-10G/20GM default communication: 9600, 8, even, 1; station: 0 RS232 communication RS422 communication - 180 -
6 Communication settings and guide of HMI connecting with controller FX 3u default communication: 9600, 7, even, 1; station: 0 RS232 communication RS422 communication Mitsubishi FX-485ADP/422BD (Multi-station) default communication: 19200, 7, even, 2; station: 0 (support multi station) - 181 -
6 Communication settings and guide of HMI connecting with controller PLC Software Setting: Note:Must modify the value of special data register. Set D8120=OXEO9E; D8121=0; D8129=1; Download and PLC restart. Q00j series RS232 communication Note: 1、 HMI default parameter: 19200, 8, odd, 1. 2、 PLC station No.:0(Non-support station number, only one HMI connect to one PLC). 3、 If communication baudrate is error, HMI automatically set PLC baudrate for the HMI baudrate.
6 Communication settings and guide of HMI connecting with controller 4、 This drives support password protection model Q00J.
6 Communication settings and guide of HMI connecting with controller Q00、Q01 PLC communication setting Q02 series CPU port communication 1.HMI Default:115200,8,odd,1 2. PLC Station No.:0(one HMI communicate with one PLC) 3.If baud rate is wrong,HMI will set the baud rate of PLC the same as HMI.
6 Communication settings and guide of HMI connecting with controller Q06H series CPU port communication 1.HMI Default:115200,8,odd,1 2. PLC Station No.:0(one HMI communicate with one PLC) 3.If baud rate is wrong,HMI will set the baud rate of PLC the same as HMI. RS232 communication QJ71C24 module communication: choose Mitsubishi Q_QnA (Link Port) or Mitsubishi Melsec Q drive Differences: 1.
6 Communication settings and guide of HMI connecting with controller RS485 Modules can also modify the baud rate, parity, station number. PLC Software Setting: a. “parameter” double-click “plc parameter”, select “I/O assignment”.
6 Communication settings and guide of HMI connecting with controller b. click “type” to select “intelligent” c.
6 Communication settings and guide of HMI connecting with controller Setting the intelligent function unit switch switch content example Switch1 CH1:transmission rate, transmission setting 0BEEH 115Kbps 8 bit 1 bit even Switch2 CH1:communication protocol MC protocol type5 binary 0005H Switch3 CH2:transmission rate, transmission setting (the same as switch 1) 0BEEH Switch4 CH2:communication protocol MC protocol type5 binary 0005H Switch5 Station No.
6 Communication settings and guide of HMI connecting with controller If the communcation parameters of CH1 232 is 19200/8/odd/1, station:0, set as follows “switch setting” in “PLC parameters” and “I/O assignment”. Note: After setting the switches, reset the PLC or turn the power off and then back on again.
6 Communication settings and guide of HMI connecting with controller PLC configuration 1. Ethernet parameters [network type] select "Ethernet"; [start I/O] is a hexadecimal number increments & H10, you can select "0"; [network number] range is 1-239, generally set at the network level, only a layer of the network, so set to "1"; [Group number] range is 0-32, select "0"; [station number] range 1-64, 1 occupied by the computer side, can be set to 2-64, the example is set to "2" ; [Model] Select "online".
6 Communication settings and guide of HMI connecting with controller set] button to save the settings. 2. Operation set 3. Open set In line 1 [protocol] selection "UDP" protocol; and that [open in pairs] option selecte "pairs",system will be prompted to ,selection is confirmed, the parameters of line 2 will be self-generated, so as to form a two-way communication. PLC's port and PC port range is & H401 - & HFFFF, the example is set to & H1000, PC's IP address is your computer's IP.
6 Communication settings and guide of HMI connecting with controller Supported Device Fx1s Device Bit Address Word Address Format Input Relay X00-17 ------ OO Output Relay Y00-15 ------ OO Auxiliary Relay M000-511 ------ DDD Timer Relay T00-63 ------ DD Counter Relay C00-31 ------ DD Data Register Relay D000.0-255.F ------ DDD.
6 Communication settings and guide of HMI connecting with controller Device Bit Address Word Address Format Input Relay X 00-67 ------ OO Output Relay Y 00-67 ------ OO Auxiliary Relay M 000-511 ------ DDD Special Auxiliary Relay ------ DDDD Data register SM9000-9175 ------ D 000-3999 DDDD Special Data Register ------ SD 9000-9599 FD 4000-6999 DDDD -----Note: bit devices don’t support batch, but word device can.
6 Communication settings and guide of HMI connecting with controller Special internal Relay SM0000-2047 ------ DDDD Internal Relay M0000-8191 ------ DDDD Output Relay Y0000-1FFF ------ HHHH Input Relay X0000-1FFF ------ HHHH File register ------ R000-7FF HHH SW0-3FF HHH Special Link register Link register ------ W000-7FF HHH Special data register ------ SD0-2047 DDDD Data register ------ D0-12287 DDDDD Counter ------ CN0-1023 DDDD Retentive timer value ------ SN0-204
6 Communication settings and guide of HMI connecting with controller Edge Relay V0000-2047 ------ DDDD Annunciator Relay F0000-2047 ------ DDDD Latch Relay L0000-8191 ------ DDDD Special Internal Relay SM0000-2047 ------ DDDD Internal Relay M0000-8191 ------ DDDD Output Relay Y0000-1FFF ------ HHHH Input Relay X0000-1FFF ------ HHHH Link register ------ W0000-1FFF HHHH Timer(Current Value) ------ TN0000-2047 DDDD Counter(Current Value) ------ CN0000-1023 DDDD File re
6 Communication settings and guide of HMI connecting with controller Special Link register ------ SW 0-7FF HHH File register ------ D 0-25983 DDDDD Data register ------ SD 0-2047 DDDD Cable Diagram FX series RS232 CPU port communication FX series programming cable using as communication cable.
6 Communication settings and guide of HMI connecting with controller Ethernet communication protocol cable Cross-connection or crossover network cable can be used as communication cable via the hub or switch a. Cross-connection cable diagram b.
6 Communication settings and guide of HMI connecting with controller Series CPU Link Module Driver BY125 BY125 RS232 on the CPU unit MKS System configuration Series CPU Link Module COMM Type Parameter Cable BY125 BY125 RS232 on the CPU unit RS232 Setting Your owner cable Communication Setting Default communication: 9600, 7, even, 1; station: 11 Supported Device Device Bit Address Word Address Format Notes Relay CB 00-FF ------ HH Register ------ CD00-FF HH External Registe
6 Communication settings and guide of HMI connecting with controller Cable Diagram Mks controller RS232 communication cable 6.
6 Communication settings and guide of HMI connecting with controller Modbus TCP Slave Ethernet Modbus UDP Ethernet Modbus UDP Slave Ethernet Connection Configuration Communication Setting Modbus RTU RS232 communication:9600, 8, even, 1; station: 1 NOTE: 1. Modbus RTU protocol supports broadcasting station number, but the radio function only supports write operations, with a reading of properties for the components, can not use the radio function; 2.
6 Communication settings and guide of HMI connecting with controller Modbus RTU Slave RS232 default communication: 9600, 8, even, 1; station: 1 Modbus RTU MT500 compatible RS232 default communication: 9600, 8, even, 1; station: 1 - 201 -
6 Communication settings and guide of HMI connecting with controller MODBUS ASCII RS232 communication: 9600, 8, even, 1; station: 1 Modbus TCP network configuration - 202 -
6 Communication settings and guide of HMI connecting with controller Modbus UDP network configuration Supported Device - 203 -
6 Communication settings and guide of HMI connecting with controller Modbus RTU Device Bit Address Word Address Format Notes Output Relay 0X1-65535 ------ DDDDD Input Relay (read only) 1X1-65535 ------ DDDDD Input Register (read only) ------ 3X1-65535 DDDDD Output Register ------ 4X1-65535 DDDDD Modbus RTU Extend Device Bit Address Word Address Format Output Relay 0X1-65535 ------ DDDDD Input Relay (read only) 1X1-65535 ------ DDDDD Input Relay (read only) 3X_bit1-65535 -
6 Communication settings and guide of HMI connecting with controller Input Relay (read only) 1X 1-65535 ------ DDDDD Input Relay (read only) 3X_bit 1.00-65535.15 ------ DDDDD.DD Data relay 4X_bit 1.00-65535.15 ------ DDDDD.DD Input Register (read only) ------ 3X 1-65535 DDDDD Output Register ------ 4X 1-65535 DDDDD Data Register ------ 4X-DINV 1-65535 DDDDD Data Register ------ 3X-DINV 1-65535 DDDDD Note: 4X-DINV, 3X-DINV is the word high and low-bit counter.
6 Communication settings and guide of HMI connecting with controller Ethernet Hub or Switch RJ45 HMI Ethernet terminal RJ45 1 TX+ (orange,white) 2 TX3 RX+ 4 BD4+ 5 BD46 RX7 BD3+ 8 BD3- (orange) (green,white) (blue) (blue,white) (green) (brown,white) (brown) 1 RX+(orange,white) 2 RX- (orange) 3 TX+ (green,white) 4 BD4+ (blue) 5 BD4- (blue,white) 6 TX(green) 7 BD3(brown,white) 8 BD3- (brown) 6.
6 Communication settings and guide of HMI connecting with controller Supported Device Device Bit Address Word Address Format Notes ------ D_1 0-9999 DDDD One byte ------ D_2 0-9999 DDDD Two byte ------ D_3 0-9999 DDDD Three byte Cable Diagram MODROL RS485 6.
6 Communication settings and guide of HMI connecting with controller System configuration Series CPU Link Module COMM Type Parameter Cable NX7 NX7 RS232 on the CPU unit RS232 Setting Your owner cable Communication Setting Default communication: 19200, 8, none, 1; station: 1 Supported Device Device Bit Address Word Address Format Input/Output Relay R 0.0–127.15 ------ DDD.DD General Relay L 0.0–63.15 ------ DD.DD General Relay M 0.0–127.15 ------ DDD.DD Keep Relay K 0.0–127.
6 Communication settings and guide of HMI connecting with controller Internal HSC ------ R_Dword 0-127 DDD General Register ------ L_Dword 0-63 DD General Register ------ M_Dword 0-127 DDD Keep Register ------ K_Dword 0-127 DDD Special Register ------ F_Dword 0-15 DD Timer/Counter Register ------ SV_Dword 0-255 DDD Timer/Counter Register ------ PV_Dword 0-255 DDD General Register ------ W_Dword 0-2047 DDDD Special Register ------ SR_Dword 0-511 DDD Cable Diagram Oemax RS
6 Communication settings and guide of HMI connecting with controller C1000HF C500-LK201-V1 C500-LK203 C20H/28H/40H Link I/F on the CPU unit C20PF/28PF C40PF/60PF C120-LK201-V1 C120-LK202-V1 C120 C120F C120-LK201-V1 C120-LK202-V1 CQM1-CPU11 Peripheral port on the CPU unit CQM1-CPU21 CQM1-CPU41 CQM1-CPU42 CQM1-CPU43 CQM1-CPU44 CQM1-CPU41-V1 CQM1-CPU42-V1 CQM1-CPU43-V1 CQM1-CPU44-V1 RS232C port on the CPU unit Peripheral port on the CPU unit Peripheral port on the CPU unit Peripheral port on the
6 Communication settings and guide of HMI connecting with controller CJ1H-CPU66H CJ1H-CPU65H SYSMAC CS1 CS1G-CPU45 CS1G-CPU44 CS1G-CPU43 CS1G-CPU42 CS1G-CPU45H CS1G-CPU44H CS1G-CPU43H CS1G-CPU42H CS1G-CPU45-V1 CS1G-CPU44-V1 CS1G-CPU43-V1 CS1G-CPU42-V1 CS1H-CPU67 CS1H-CPU66 CS1H-CPU65 CS1H-CPU64 CS1H-CPU63 CS1H-CPU67H CS1H-CPU66H CS1H-CPU65H CS1H-CPU64H CS1H-CPU63H CS1H-CPU67-V1 CS1H-CPU66-V1 CS1H-CPU65-V1 CS1H-CPU64-V1 CS1H-CPU63-V1 RS232 on the CPU unit Peripheral port on the CPU unit Omron CJ_CS Seri
6 Communication settings and guide of HMI connecting with controller SYSMAC CJ SYSMAC CS CJ1G-CPU45 CJ1G-CPU44 CJ1G-CPU45H CJ1G-CPU44H CJ1G-CPU43H CJ1G-CPU42H CJ1M-CPU23 CJ1M-CPU22 CJ1M-CPU21 CJ1M-CPU13 CJ1M-CPU12 CJ1M-CPU11 CJ1H-CPU66H CJ1H-CPU65H RS232 on the CPU unit RS232 Setting Your owner cable Peripheral port on the CPU unit (Must set the switch DIP 4 to be on) RS232 Setting Your owner cable CS1G-CPU45 CS1G-CPU44 CS1G-CPU43 CS1G-CPU42 CS1G-CPU45H CS1G-CPU44H CS1G-CPU43H CS1G-CPU42H CS1G-C
6 Communication settings and guide of HMI connecting with controller Series CPU Link Module Connect Type Parameter Cable SYSMAC CJ CJ2M-CPU35 CJ1W-ETP21 Ethernet Setting Your owner cable Serial Communication Setting OMRON CP1H_CP1L default communication: 9600, 7, even, 2; station: 0 CP1W-CIF01 RS232 communication CP1W-CIF01 RS422 communication Note:cp1h switch DIP1—6 all set OFF. NO.
6 Communication settings and guide of HMI connecting with controller 5 ON: communication port2,Toolbus(default) OFF:Port 2 communications settings according to the PLC system CPU setting OFF 6 ON: customer use ( A395.12 = ON) OFF: customer use ( A395.
6 Communication settings and guide of HMI connecting with controller Note: Select custom communication parameters (non-standard communication parameters), the switch of plc must be OFF. Omron CJ1M-CPU22 RS232 default communication: 9600, 7, even, 2; station: 0 Note:1.CJ1M switch DIP: sw1, sw2, sw3, sw5, sw8 must be off, but sw4, sw6, sw7 are optional. 2. CJ1M switches DIP 1—8 are OFF (default).
6 Communication settings and guide of HMI connecting with controller Network Communication Setting HMI Network configuration PLC setting 1.
6 Communication settings and guide of HMI connecting with controller 2. Double-click the Ethernet communication module, set the parameters Supported Device Omron C Series Host Link Device Latch Relay Data Memory Relay Data Link Relay Auxiliary Memory Relay Bit Address Word Address Format HR00.00-99.15 ------ DD.DD DM0000.00-6655.15 ------ DDDD.DD LR00.00-63.15 ------ DD.DD AR00.00-959.15 ------ DD.
6 Communication settings and guide of HMI connecting with controller Internal Auxiliary Relay CIO_IR000.00-511.15 ------ DDD.
6 Communication settings and guide of HMI connecting with controller Data Memory DM00000.00-32767.15 ------ DDDDD.
6 Communication settings and guide of HMI connecting with controller Omron CJ\CS series Peripheral port on the CPU unit When connecting the peripheral port on the CPU by the conversion adapter, set DIP4 to on. Omron CP1H RS422 communication cable Note: When connecting by the 4-wire method, set DIP1~6 to off. (The dip on the back of option board) Omron CP1H RS485 communication cable Note: When connecting by the 2-wire method, set DIP1 to off, DIP 2, 3, 5, 6 to on.
6 Communication settings and guide of HMI connecting with controller HMI Ethernet terminal RJ45 1 TX+ (orange,white) 2 TX3 RX+ 4 BD4+ 5 BD46 RX7 BD3+ 8 BD3- (orange) (green,white) (blue) (blue,white) (green) (brown,white) (brown) Ethernet Hub or Switch RJ45 1 RX+(orange,white) 2 RX- (orange) 3 TX+ (green,white) 4 BD4+ (blue) 5 BD4- (blue,white) 6 TX(green) 7 BD3(brown,white) 8 BD3- (brown) 6.
6 Communication settings and guide of HMI connecting with controller Supported Device OMRON E5EZ-R3 Device Bit Address Word Address Format Notes DDD.H H Main addr indicates variable type 0(C0),1(C1),2(C3) subaddress indicates address of variable type 0.0 — 0.A (C0 read only) Variable ------ 1.0 — 1.2D (C1) 2.0 — 2.
6 Communication settings and guide of HMI connecting with controller RS232 communication, need to use RS-232 to RS-422/485 converter 6.
6 Communication settings and guide of HMI connecting with controller Network Configuration Supported Device Device Bit Address Word Address Format Bit Table B0-65535 —— DDDDD Bit Table BT0.000-65535.255 —— DDDDD.DDD Integer 32 —— N32 0-65535 DDDDD Float —— FN0-65535 DDDDD UP Timer —— UTN0-65535 DDDDD Down Timer —— DTN0-65535 DDDDD PID parameter —— PIDSN0.00-32.06 DDDDD.DD Integer 32 Table —— NT0.000-65535.255 DDDDD.DDD Float Table —— FT0.000-65535.255 DDDDD.
6 Communication settings and guide of HMI connecting with controller QN BIT PIN Float PQN Float NT Double FT Float B BIT(the attribute of B is the same as N32 in the PLC software) BT BIT(the attribute of BT is the same as NT in the PLC software) Note: 1、 The configuration in OPTO 22 software must be the same as the configuration in Kinco HMIware software: true:e.g.: define Float in the OPTO 22 software,F1 Select FN device in the Kinco HMIware software, address: 1.
6 Communication settings and guide of HMI connecting with controller b. crossover network cable HMI Ethernet terminal RJ45 Ethernet Hub or Switch RJ45 1 TX+ (orange,white) 2 TX3 RX+ 4 BD4+ 5 BD46 RX7 BD3+ 8 BD3- (orange) (green,white) (blue) (blue,white) (green) (brown,white) (brown) 1 RX+(orange,white) 2 RX- (orange) 3 TX+ (green,white) 4 BD4+ (blue) 5 BD4- (blue,white) 6 TX(green) 7 BD3(brown,white) 8 BD3- (brown) 6.
6 Communication settings and guide of HMI connecting with controller Communication Setting HMI Compax3 RS232 default communication: 115200, 8, none, 1; station: no address RS485-2 default communication: 9600, 8, none, 1; station: 1 Note: RS-485 Settings can be made in the C3 Servo Manager under “RS485 settings” - 227 -
6 Communication settings and guide of HMI connecting with controller SLVD Series RS485 communciation: 9600, 8, 1, even; station: 0 6k RS232 default communication: 9600, 8, 1, none; station: 0 注:不支持 485 通讯。 Supported Device Compax3 Device Bit Address Word Address Format R_Bit 0.0-9999999.31 ------ DDDDDDD.DD ------ R_Float 0.0-9999.511 DDDD.DDD ------ R_Int 0.0-9999.511 DDDD.DDD Note: R_Bit device is the bit format of R_Int device. The address of R_Bit device is DDDDDDD.
6 Communication settings and guide of HMI connecting with controller SLVD Series Device Bit Address Word Address Format Pr_Bit 0-9999.15 ------ DDDD.
6 Communication settings and guide of HMI connecting with controller 6k Series Device Bit Address Word Address Format Notes VARB_bit 1.00~125.31 ------ DDD Read only The real number value in register ------ VAR_float 1~225 DDD The integer number value in register ------ VAR_int 1~225 The 32-bit hexadecimal value in register ------ VARB 1~125 Bit in register DDDD DDD Note: VARB configuration software need to use hexadecimal data type, integer-bit to 8 bits.
6 Communication settings and guide of HMI connecting with controller SLVD Series RS485-2 6k Series RS232 6.
6 Communication settings and guide of HMI connecting with controller Communication Setting Supported Device Device Bit Address Word Address Format Notes I variable ------ I 0-9999 DDDD R/W M variable ------ M 0-9999 DDDD R/W P variable ------ P 0-9999 DDDD R/W Q variable ------ Q 0-9999 DDDD R/W ------ I_float 0-9999 DDDD R/W I variable Float P variable Float ------ P_float 0-9999 DDDD R/W Q variable Float ------ Q_float 0-9999 DDDD R/W report position of motor
6 Communication settings and guide of HMI connecting with controller (6) ORD/JOG 0060: # n (7) ORD/JOG 0070: home(hm):manual reset zero commands (8) ORD/JOG 0080: homez(hmz):manual reset zero position commands PMAC common programming commands (0) ORD/JOG 0100:& n (1) ORD/JOG 0110:B m R (2) ORD/JOG 0120:B m S (3) ORD/JOG 0130:A(ctrl A):Stop movement program (4) ORD/JOG 0140:K(ctrl K):Stop movement program and close enable signal (5) ORD/JOG 0150: Enable PLC n:Enable PLC, n indicates prog no.
6 Communication settings and guide of HMI connecting with controller Supported Device Device Bit Address Word Address Format Time Register(double word) ------ Time 0-9999.7 DDDDD.0 Energy Register(double word) ------ Energy 0-9999.7 DDDDD.0 Status variable Register(double word) ------ Measure 0-9999.7 DDDDD.0 Hardware version(double word) ------ Fireware 0-9999.7 DDDDD.0 Software version(double word) ------ Version 0-9999 DDDD Device sequence No.
6 Communication settings and guide of HMI connecting with controller 6.
6 Communication settings and guide of HMI connecting with controller Note:Input and Output Modules should match with Master configuration PLC setting Note: you can find eview.gsd in the fieldbus file of Kinco HMIware Installation Directory, or you can download from www.kinco.cn. 1. Setup eview.gsd file Setup GSD file in the s7-300 software. Process: (1). Closed all the station in HW Config (2).choose “option” > “install GSD file”. (3).Find out the folder of eview.gsd. (4).Choose eview.
6 Communication settings and guide of HMI connecting with controller (4)right click,choose “insert object” Click “eview_MT5K_ProfibusDP_V1.0”,set address. Note: the address No. of DP master station and slave can not be same.
6 Communication settings and guide of HMI connecting with controller (6)Profibus DP Slave has adaption function,you can change the transmission rate of DP master station, maximum is 12Mbps.
6 Communication settings and guide of HMI connecting with controller Direct I/O Input LW.B8500.0~8615.F ———— DDDD.H Direct I/O Output LW.B8000.0~8115.F ———— DDDD.
6 Communication settings and guide of HMI connecting with controller Supported Device Device Bit Address Word Address Format Bit LB 8999 ------ DDDD ------ LW 8900 DDDD Notes Note: LB8999 means bar code has received or not. 1 means data has received. Cable Diagram 6.58 RKC Instrument INC.
6 Communication settings and guide of HMI connecting with controller Communication Setting HMI Default communication: 9600, 8, none, 1; station: 1 RS485 Controller setting Press “SET” key and “﹤R/S” key at one time,then press the SET key and select parameters: Add Address *1 bPS Baudrate *2 bIT data instruction *3 InT transmission delay *4 *1: Two bits ASCII code.
6 Communication settings and guide of HMI connecting with controller Supported Device Device Bit Address Word Address Format Notes Alarm 1 status AA: 0 ------ D Read only Burnout B1: 0 ------ D Read only PID control/Autotuning G1: 0 ------ D R/W Alarm 2 status AB: 0 ------ D Read only RUN/STOP transfer SR: 0 ------ D R/W Self-tuning G2:0 ------ D R/W Measured value ------ M1: 0 D Read only Current transfomer input1 ------ M2: 0 D Read only Current transfomer inp
6 Communication settings and guide of HMI connecting with controller 6.
6 Communication settings and guide of HMI connecting with controller Motor controller status ———— LW8015 DDDD Bus voltage ———— LW8020 DDDD Battery charge / discharge current ———— LW8021 DDDD SOC ———— LW8022 DDDD SOC alarm signal ———— LW8023 DDDD Battery Management System LIFE ———— LW8024 DDDD battery status ———— LW8025 DDDD The maximum value of the single voltage ———— LW8030 DDDD The maximum number single voltage ———— LW8031 DDDD Single voltage minimum value ———— LW803
6 Communication settings and guide of HMI connecting with controller 6.60 Saia-Burgess Serial Communication Series CPU Link Module Driver PCS PCS1.C8 RS232 on the CPU unit PCD PCD2.M110 PCD2.M120 PCD2.M150 PCD2.M170 PCD2.M480 RS232 on the CPU unit Saia SBus Systems Configuration Series CPU PCS PCS1.C8 PCD PCD2.
6 Communication settings and guide of HMI connecting with controller Supported Device Device Bit Address Word Address Format Input I0-8091 ------ DDDDD Output O0-8091 ------ DDDDD Flag F0-8091 ------ DDDD Timer ------ T0-1599 DDDD Counter ------ C0-1599 DDDD Register ------ R0-4095 DDDD ------ R_Float0-4095 DDDD Register(support single float point) Cable Diagram Pcs1.c8 RS232 communication cable PCD2.
6 Communication settings and guide of HMI connecting with controller Pcs1.c8 RS485 communication cable 6.
6 Communication settings and guide of HMI connecting with controller Supported Device Device Bit Address Word Address Format Channel Sample Value ------ CH 0~16 DD Channel Indexing ------ SN 1~16 DD Notes Cable Diagram Sailsors D9 RS485 communication cable 6.62 Schneider Electric, Ltd.
6 Communication settings and guide of HMI connecting with controller TSX 37 10 164DTK1 TSX 37 10 028AR1 TSX 37 10 028DR1 TSX 37 21 101 TSX 37 22 101 TSX 37 21 001 TSX 37 22 001 Premium TSX P57 103M TSX P57 153M TSX P57 203M TSX P57 253M TSX P57 303M TSX P57 353M TSX P57 453M TER port on the CPU Nano TSX 07 3L 28 TSX 07 30 10 TSX 07 31 16 TSX 07 31 24 TSX 07 32 28 TSX 07 33 28 Programming port on CPU Twido TWD LCAA 10DRF TWD LCAA 16DRF TWD LCAA 24DRF TWD LMDA 20DTK TWD LMDA 2
6 Communication settings and guide of HMI connecting with controller TSX 37 22 101 TSX 37 21 001 TSX 37 22 001 TSX3705001 TSX3705001 TSX 37 05 028DR1 TSX 37 08 056DR1 TSX 37 10 128DT1 TSX 37 10 128DR1 TSX 37 10 128DTK1 TSX 37 10 164DTK1 TSX 37 10 028AR1 TSX 37 10 028DR1 TSX 37 21 101 TSX 37 22 101 TSX 37 21 001 TSX 37 22 001 Twido TWD LCAA 10DRF TWD LCAA 16DRF TWD LCAA 24DRF TWD LMDA 20DTK TWD LMDA 20DUK TWD LMDA 20DRT TWD LMDA 40DTK TWD LMDA 40DUK RS485 on the CPU unit Modbus RTU RS485 on the CPU uni
6 Communication settings and guide of HMI connecting with controller RS485 communication protocol default communication:9600, 8, even, 1; station: 1.
6 Communication settings and guide of HMI connecting with controller PLC Setting 1. Sort menu-“modicum telemecanique” “xway driver manager” to set communication parameter 2. Pop-up to select “unitelway driver””configuration””edit” to modify communication parameter 3.
6 Communication settings and guide of HMI connecting with controller 4. And then click ”xway test””connect”, if the connection is successful, it will clue “connected” 5.
6 Communication settings and guide of HMI connecting with controller Modbus protocol setting:: 6.
6 Communication settings and guide of HMI connecting with controller station: 1 Note: Cable by Schneider Electric Industries, Rotary switch setting: 2(TER Direct). RS232 communication RS485communication Twido Software setting 1. Specify a large number for the internal word in the “controller > memory use >edit” and load the configuration into the PLC to open the memory area for the words. If set the internal word 3000, you can use address of MW before 3000.
6 Communication settings and guide of HMI connecting with controller 2. You must program a coil with maximum address to open the memory area for the Bits. If you program a coil with 127 addresses, then the address before 127 can be used. Supported Device Modicon TSX Device Bit Address Word Address Format Internal Relay S00000-32767 ------ DDDDD Auxiliary Relay M00000-32767 ------ DDDDD Data Register Relay MW.B0000-9999.F ------ DDDD.
6 Communication settings and guide of HMI connecting with controller e.g.: M0 corresponds to OX1. Don’t use 1X, 3X device, because there is no correspondence with the PLC. Cable Diagram Uni-TelWay RS232 Cable recommended by Schneider Electric Industries, Rotary switch setting: 2(TER Direct)(Add a direct line) Uni-TelWay RS485 Modicon modbus Protocol RS232 PLC software setting: “Hardware Configuration”double click “Ccom” to select “MODBUS/BUS LINK”; others are default parameters.
6 Communication settings and guide of HMI connecting with controller 6.
6 Communication settings and guide of HMI connecting with controller Sequence code(Read Only) ------ Array Code 0-3 H Basic parameter value(Read Only) ------ Basic_Read 00-42 HH OUT1_W,OUT2_W(Write Only) ------ Out_Write 0-1 H PV1,PV2(Read Only) ------ PV_Read 0-1 H Reference(Read & Write) ------ Reference 300-952 HHH Basic_Read operatable address PLC addr (HEX) Parameter R/W Parameters mean 00H PV_W Read Measurements 01H SV_W Read Setting value 02H OUT1_W Read Output1 va
6 Communication settings and guide of HMI connecting with controller Reference operatable address example PLC Addr(HEX) Parameter R/W 300H FIX_SV R/W Parameters mean FIX mode SV: in the limit range of SV R/W PB21 ratio coefficient:0.0 to 999.9%(0.0=OFF) 460H About device address details, please refer to the FP23 communication protocol. Show: H indicates HEX Note: 1、Setting the parameters of ADDR address, the settings must be the same as the corresponding PLC station.
6 Communication settings and guide of HMI connecting with controller CPU314 CPU314IFM CPU315 CPU315-2 DP CPU316 CPU316-2 DP CPU318-2 CPU412-1 CPU412-2 DP CPU413-1 CPU413-2 DP CPU414-1 CPU414-2 DP CPU414-3 DP CPU416-1 CPU416-2 DP CPU416-3 DP CPU417-4 S7-400 port) *1 MPI port on the CPU unit Note:Don’t hot plug!!! Ethernet Communication (Direct online simulation disable) Series CPU Link Module Driver SIMATIC S7-200 CPU222 CPU224 CPU224 XP CPU226 CP 243-1 IT CP 243-1 Siemens S7-200 Network Slave
6 Communication settings and guide of HMI connecting with controller S7-300 CPU312IFM CPU313 CPU313C CPU314 CPU314IFM CPU315 CPU315-2 DP CPU316 CPU316-2 DP CPU318-2 RS232 S7-300/400 (PC Adapter) Setting Your owner cable RS485 S7-300/400 (via MPI port) Setting Your owner cable MPI port on the CPU unit Ethernet System configuration Series CPU Link Module Connect Type Parameter Cable SIMATIC S7-200 CPU222 CPU224 CPU224 XP CPU226 CP 243-1 IT CP 243-1 Ethernet Setting Your owner cable SIMAT
6 Communication settings and guide of HMI connecting with controller S7-200 software setting Siemens S7-300/400 (PC Adapter) driver protocol 1. If you use adapter to communicate, PLC must be 187.5K. 2. HMI communication setting: 19200, 8, 2, odd; station No.: 2 3. If we use PC adapter, PLC station No. is not necessary, so the communication is one-to-one. 4. DB block must be created, otherwise the relevant registers can not write (DB.DBX, DB.DBW, DB.DBD). DBm.DBW, DBm.
6 Communication settings and guide of HMI connecting with controller Siemens S7-300/400 (PC Adapter) drive software setting A)Production of the adapter with eview, MPI transmission rate must be set 187.5K. 19.2K general users of the transmission rate, if the S7-300 MPI-side transmission rate is 19.2K, you need to change it into the Siemens adapter 187.5K (where changes in the hardware properties) B)MPI address must be 2.
6 Communication settings and guide of HMI connecting with controller C) After the software change, downloaded to PLC, make sure the transmission rate of MPI is 187.5K, and then in the options set PG / PC interface, select PC Adapter (MPI), MPI-side of the transfer rate will be changed to 187.5K.
6 Communication settings and guide of HMI connecting with controller Siemens S7-300/400 (via MPI port) driver protocol 1. This drive only comport the HMI with MPI port. Don’t support indirect online and direct online simulation. 2. MPI is RS485 port, so we can use this drive to communicate between many HMI and PLC, and then we must set the master station No.. 3. HMI station No. can be 0~15, PLC station No. must be 0~15, the station No. of HMI and PLC can not be the same number. 4. PLC baud rate is 187500.
6 Communication settings and guide of HMI connecting with controller Siemens S7-300/400 (via MPI port) drive software setting 1. PLC station No. can be 0~15. 2. MPI baud rate can be 19.2k or 187.5k.
6 Communication settings and guide of HMI connecting with controller a. Siemens S7-200 Network Slave HMI Network configuration PLC configuration The settings for the CP 243-1 are defined in STEP 7 Micro/WIN via the Ethernet Wizard. For assistance with all the information go to STEP 7 Micro/WIN Online Help via F1. 1. Starting the Ethernet Wizard Open STEP 7 Micro/WIN Start the Ethernet Wizard via “Tools >Ethernet Wizard….
6 Communication settings and guide of HMI connecting with controller 2. Specifying module position If your PC is connected to the S7-200, click the “Read modules” button to determine the position of the CP 243-1 module automatically. Otherwise, the module position can also be entered manually. Important: The panel can only establish a connection with a Cp243-1 if the module is configured to “position 0”.
6 Communication settings and guide of HMI connecting with controller 4. Parameterizing PtP connection Specify the command byte for the module and the number of point-to-point connections with the CP 243-1 . Click on “Next”. 5. Configuration connection The configuration for connecting the CP 243-1 to the panel must be defined as in Fig.. Click OK to confirm the entries. Warning: The TSAP must always be specified in four-digit format, with a leading zero (02.00).
6 Communication settings and guide of HMI connecting with controller 6. Using CRC protection Set the CRC protection the way you want it. It is advisable to work without CRC protection first of all. The “Keep Alive Interval” can be specified with the default time. Activate the CRC protection and change the time of the “Keep Alive Interval” if required. Click on “Next”. 7. Assigning memory Specify a memory area for the configuration of the CP 243-1.
6 Communication settings and guide of HMI connecting with controller 8. Creating project components If you click on “Close”, the Ethernet Wizard generates the project components for the set configuration. Among other things, subprograms and the variable memory are created in the data block. 9. Confirm message Click “Yes” to confirm the message that appears. 10. Call ETH0_CTRL In your STEP 7 Micro/WIN program, you must call the ETH0_CTRL subroutine in each cycle.
6 Communication settings and guide of HMI connecting with controller b. Siemens S7-1200 Network Slave HMI Network configuration PLC configuration 1.
6 Communication settings and guide of HMI connecting with controller 2. After configuration, download device. Download in the first time, select the “Extended download to device”, in the dialog to select show all accessible devices. 3. Select the device, press “Load”. c.
6 Communication settings and guide of HMI connecting with controller Network configuration PLC configuration 1. In “HW configuration” insert CP300 industrial Ethernet. 2. Set IP address in the Properties of CP343-1.
6 Communication settings and guide of HMI connecting with controller 3. After HW configuration, download. Supported Device S7-200 Device Bit Address Word Address Format S.B0.0-255.7 ------ DDD.O SM.B0-4399.7 ------ DDDD.O Counter Relay Cnt0-255 ------ DDD.O Timer Relay Tim0-255 ------ DDD.O V Relay V.B0.0-32768.7 ------ DDDDD.O Internal Memory Relay M.B0.0-32768.7 ------ DDDDD.O Discrete outputs and image Relay Q.B0.0-32768.7 ------ DDDDD.O Discrete inputs and image Relay I.
6 Communication settings and guide of HMI connecting with controller SCR double word ------ SD0-28 DD SCR ------ SW0-30 DD Special memory double word ------ SMD0-546 DDD Special memory ------ SMW0-548 DDD Internal memory double word ------ MD0-28 DD Internal memory ------ MW0-30 DD Discrete outputs and image register double word ------ QD0-12 DD Discrete outputs and image register ------ QW0-14 DD Discrete inputs and image register double word ------ ID0-12 DD Discrete i
6 Communication settings and guide of HMI connecting with controller Data Register Relay (32 bit) ------ DBm.
6 Communication settings and guide of HMI connecting with controller External Output node Q 0.0~127.7 ------ DDDD.O Internal assistant node M 0.0~2047.7 ------ DDDD.O Data Register Relay node DBn_DBX 100000.0~25565535.7 ------ DDDDDDDD.O Data Register Relay node DBm_DBX 0.0~65535.7 ------ DDDDD.
6 Communication settings and guide of HMI connecting with controller Data Register Relay (32 bit) ------ DBm_DBD 0-65532 DDDDD Internal Relay ------ MW 0~2046 DDDD Internal Relay (32 bit) ------ MD 0~2044 DDDD External Output Relay ------ QW 0~126 DDD External Output Relay (32 bit) ------ QD 0~124 DDD External Input Relay ------ IW 0~126 DDD -----ID 0~124 DDD External Input Relay (32 bit) Note: DBn_DBX, DBn_DBW, DBn_DBD is a custom block.
6 Communication settings and guide of HMI connecting with controller 2. Long distance communication with MPI adapter: Extend the RS485 port: The cable length must be 600m or less in the 187.5k ,the 7 pin and 2 pin must connect with 24v power in the port of RS485, the 8 pin and 3 pin must connect with 120Ωterminal resistance. 3.
6 Communication settings and guide of HMI connecting with controller b. cross-over cable cable diagram: HMI Ethernet terminal RJ45 1 TX+ 2 TX3 RX+ 4 BD4+ 5 BD46 RX7 BD3+ 8 BD3- Ethernet Hub or Switch RJ45 (orange,white) ( orange) (green,white) (bule) (bule,white) (green) (brown,white) (brown) 1 RX+(orange,white) 2 RX- (orange) 3 TX+ (green,white) 4 BD4+ (bule) 5 BD4- (bule,white) 6 TX(green) 7 BD3(brown,white) 8 BD3- (brown) 6.
6 Communication settings and guide of HMI connecting with controller RS485 Supported Device Device Bit Address Word Address Format Input Relay(receive external switch signal) X0-377 ------ OOO Output Relay Y0-377 ------ OOO M(0-7679)& (8000-8511) ------ DDDD Step Relay S0-4096 ------ DDDD Timer Relay T0-511 ------ DDD Counter Relay C0-255 DDD Data Register ------ -----D0-8511 DDDD Data Register ------ Z0-15 DD Data Register ------ V0-15 DD Timer(Current value) ------
6 Communication settings and guide of HMI connecting with controller Counter ------ C_Current_Double 200-255 DDD Timer(Preset value) ------ T_Preset_Word 0-511 DDD Counter(Preset value) ------ C_Preset_Word 0-199 DDD Counter ------ C_Preset_Double 200-255 DDD Note: Z, V is the turn of the write and read out. When testing a single word, max interval of word block pack and max word block package size are changed to 1.
6 Communication settings and guide of HMI connecting with controller Default communication: 9600, 8, none, 1; station: 1 Supported Device Please refer to TMCL Reference Manual for device details TMCM_303 Device Bit Address Word Address Format Notes ROR ------ 0-2 D Write Only ROL ------ 0-2 D Write Only MST 0-2 ------ D Write Only MVP ------ 0.0-2.7 DD.D Write Only SAP 0.008-0.013 1.008-1.013 2.008-2.013 0.0-2.213 DDDD.DDD Write Only GAP 0.008-0.013 1.008-1.013 2.008-2.
6 Communication settings and guide of HMI connecting with controller RFS ------ DWord 0.0-2.2 DD.D Write Only SIO 0-7 ------ D Write Only GIO 0.0-0.10 2.0-2.07 1.0-1.7 DDD.DD Read Only CALC ------ 0-9 D Write Only COMP ------ 0 D Write Only JC ------ 0-9 DD Write Only JA ------ 0 D Write Only CSUB ------ 0 D Write Only RSUB 0 ------ D Write Only WAIT ------ 0.0-4.7 DD.D Write Only STOP 0 ------ D Write Only Cable Diagram RS232 Communication Cable 6.
6 Communication settings and guide of HMI connecting with controller Supported Device Device Bit Address Word Address Format Internal Relay M0~M7999 ------ DDDDD Input Relay X0.0~X51.1 ------ OOOOOO.O Output Relay Y0.0~Y51.1 ------ OOOOOO.
6 Communication settings and guide of HMI connecting with controller S0~S1023 0X 20481~0X 21504 M8000~M8511 0X 24577~0X 25088 T0~T618 0X 25601~0X 26219 C0~C634 0X 27649~0X 28283 words Addr MODBUS addr(Decimal K) D0~D7999 4X 1~4X8000 TD0~TD618 4X 12289~4X12907 CD0~CD634 4X 14337~4X 14971 D8000~D8511 4X 16385~4X 16896 FD0~FD1535 4X 18433~4X19968 FD8000~FD8511 4X 26625~4X 27136 Register Area: Cable Diagram XC3-32R-E RS232 Communication XC3-32R-E RS485 Communication Note:A\B pin is on
6 Communication settings and guide of HMI connecting with controller System configuration Series CPU Link Module COMM Type Parameter D3CellTM D3CellTM RS485 on the CPU unit RS422 Setting Cable Your owner cable Supported Device For detailed device, please refer to the PLC manual. Communication Setting Cable Diagram HMI terminal 9pin D-SUB female\male Controller RS422 terminal com0/com1 1 RX4 TX6 RX+ 9 TX+ Blue(TX-) Yellow(RX-) White(TX+) Green(RX+) 6.
6 Communication settings and guide of HMI connecting with controller Modbus RTU Extend System configuration Series CPU TRIO Euro 205x Modbus RTU Extend Euro 205x Link Module COMM Type Parameter Cable RS232 on the CPU unit RS232 Setting Your owner cable RS485 on the CPU unit RS485-4 Setting Your owner cable RS232 on the CPU unit RS232 Setting Your owner cable RS485 on the CPU unit RS485-4 Setting Your owner cable Communication Setting Omron Protocol default communication: 9600, 7,
6 Communication settings and guide of HMI connecting with controller Controller internal setting: Modbus protocol default communication: 9600, 8, even, 1; station: 1 RS232 communication RS485-4 communication - 291 -
6 Communication settings and guide of HMI connecting with controller Trio controller communication settings Omron protocol: define Host Link slave node HLS_NODE=1 define Host Link slave mode code HLS_MODEL=$FA Set up Host Link slave for port 2 Trio controller setting:SETCOM (baudrate, databits, stopbits, parity, port, 5) SETCOM(9600,7,2,2,2,5) MC controller unit can communicate with plc terminal after setting the configuration. Note:A is the programming port of controller,B is the communication port.
6 Communication settings and guide of HMI connecting with controller Data register ———— 4X 0-1023 DDDDD Note: Address correspondence: 4x corresponds to VR; 4x_bit corresponds to VR’s bit. Address difference between one position, e.g. 4x (501) corresponds to VR (500); 4x_bit (67.1) corresponds to the first bit of VR (66). Cable Diagram Programming Cable RS232 Communication Cable RS422 Communication Cable 6.
6 Communication settings and guide of HMI connecting with controller Network Communication Series CPU Link Module Driver Vision 130 V130-33-B1 Ethernet I/F on CPU Unit Unitronics Ethernet Slave Serial System configuration Series CPU Vision 130 V130-33-B1 Link Module COM Type Parameter Cable RS232 on the CPU unit RS232 Setting Your owner cable RS485 on the CPU unit RS485-2 Setting Your owner cable Network System configuration Series CPU Link Module Connect Type Parameter Cable
6 Communication settings and guide of HMI connecting with controller Note: 1. Com Initialize in the progam software by RS485 communication. 2. Initialize ID, and progarm as below , download to controller. 3. Change the jumper position and choose RS485 communication.
6 Communication settings and guide of HMI connecting with controller Network Communication Setting HMI Network configuration Supported Device Device Bit Address Word Address Format Notes Inputs I 0~999 ------ DDD Read only Outputs O 0~999 ------ DDD Memory Bits MB 0~8191 ------ DDDD System Bits SB 0~999 ------ DDD Timers T 0~383 ------ DDD Read only Counters C 0~31 ------ DD Read only Memory Integer ------ MI 0~4095 DDDD Memory Longer ------ ML 0~511 DDD Double Wor
6 Communication settings and guide of HMI connecting with controller System Longer ------ SL 0~199 DDD System Double Word ------ SDW 0~199 DDD Timers Preset ------ T_C 0~383 DDD Read only Timers Current ------ T_P 0~383 DDD Read only Counters Preset ------ C_C 0~31 DD Read only Counters Current ------ C_P 0~31 DD Read only Cable Diagram RS232 RS485-2 Ethernet communication protocol cable Cross-connection or crossover network cable can be used as communication cable via the hub
6 Communication settings and guide of HMI connecting with controller HMI Ethernet terminal RJ45 1 TX+ (orange,white) 2 TX3 RX+ 4 BD4+ 5 BD46 RX7 BD3+ 8 BD3- (orange) (green,white) (blue) (blue,white) (green) (brown,white) (brown) Ethernet Hub or Switch RJ45 1 RX+(orange,white) 2 RX- (orange) 3 TX+ (green,white) 4 BD4+ (blue) 5 BD4- (blue,white) 6 TX(green) 7 BD3(brown,white) 8 BD3- (brown) 6.
6 Communication settings and guide of HMI connecting with controller Supported Device Device Bit Address Word Address Format send LB 0 ------ D clear LB1 ------ D Send data buffer ------ LW 0~99 DD Receive data buffer ------ LW 100~199 DDD Cable Diagram RS232 6.
6 Communication settings and guide of HMI connecting with controller System configuration Series CPU Link Module COMM Type Parameter Cable VH VH-14MR RS232 on the CPU unit RS232 Setting Your owner cable VB0 VB0-14MR RS232 on the CPU unit RS232 Setting Your owner cable Communication Setting Default communication: 19200, 7, even, 1; station: 0 Note:CP1* baudrate 19200bps. *:CP1 programming port is USB(RS232.
6 Communication settings and guide of HMI connecting with controller VH-14MR RS232 communication cable 1. Communication via USB programming port Connection with HMI by programming cable of Vigor 2. Communication via auxiliary interface of programming device: 6.
6 Communication settings and guide of HMI connecting with controller Supported Device Device Bit Address Word Address Format Addr communication parameter ------ Addr HHHH A FWD ------ A0 D B REV ------ B0 D C FJOG ------ C0 D D RJOG ------ D0 D E Free halt ------ E0 D F Slow down ------ F0 D G Reset failures ------ G0 D Address definition of inverter communication parameter Please refer to XILIN frequency converter manual for details about device address.
6 Communication settings and guide of HMI connecting with controller 6.
6 Communication settings and guide of HMI connecting with controller DMC RS485 default communication: 19200, 8, even, 1; station: 6. PLC Setting 1. Set modbus RTU in the SLP-D10, and then download. 2. Station match with the switch on the device.
6 Communication settings and guide of HMI connecting with controller Supported Device DCP30 Device Bit Address Word Address(Parameter code) Format RUN Status ------ 1-26 DDD PARA ------ 1-33 DDD EU ------ 1-13 DDD PID ------ 1-80 DDD SET ------ 1-99 DDD TBL ------ 1-22 DDD CNST ------ 1-26 DDD FO_R 1-19 ------ DDD FO_W 1-19 ------ DDD FC 1-19 ------ DDD FD 1-19 ------ DDD FBR1_R ------ 1.0-30.22 DDD.DD FBR2_R ------ 1.0-30.22 DDD.DD FBR3_R ------ 1.
6 Communication settings and guide of HMI connecting with controller When connecting multiple instruments, for distinguishing instruments, each instrument must be set C84 value with a different parameter. . 3、Must press “FUNC+PARA” to set the parameter; 4、PROG. have 19 numbers and SEG have 30 numbers, press DOWN key (sub) and PROG key (add) to change program number; 5 、 Press “FUNC+PROG” to change the program.
6 Communication settings and guide of HMI connecting with controller DC30 RS485 communication cable RS232 communication,need to use RS-232 to RS-422/485 converter SDC36 RS485 communication DMC RS485 communication 6.
6 Communication settings and guide of HMI connecting with controller Series CPU V(Inverter) MP(Motion Controller) MP2200 MP2300 MP2310 MP2300S ∑Ⅱ/∑Ⅱ Plus(Servo Controller) SGDM Link Module Driver RS485 on the CPU unit Yaskawa AH Modbus RTU RS232 on the CPU unit Yaskawa MP2300 RS232 on the CPU unit RS422 on the CPU unit Yaskawa SGDM Network communication (support indirect online and direct online) Series CPU Link Module Driver MP series MP2400 ETH on the CPU unit Yaskawa UDP Serial Sy
6 Communication settings and guide of HMI connecting with controller MP2300 RS232 default communication: 19200, 8, even, 1; station: 1 SGDM Default communication: 9600, 7, even, 1; station: 0 RS232 communication - 309 -
6 Communication settings and guide of HMI connecting with controller RS422 communication Network Communication Setting Network communication ※Project construction ※HMI Attribute - 310 -
6 Communication settings and guide of HMI connecting with controller ※PLC Attribute (station is not necessary) ※Network configuration(Note:IP and port must be set correct, that is set as MPE720 software.
6 Communication settings and guide of HMI connecting with controller 1. set the IP,connect with the MPE720 software 2.
6 Communication settings and guide of HMI connecting with controller Change, save, and save to flash: Restart the controller and the set is ok.
6 Communication settings and guide of HMI connecting with controller Supported Device V inverter Device Bit Address Word Address Format Internal/external output node 0X1-65535 ------ DDDDD 1X1-65535 ------ DDDDD Simulant input data register ------ 3X1-65535 DDDDD data register ------ 4X1-65535 DDDDD Internal/external input node Notes Node: this drive can not provide write batch of word part MP2300 Device Bit Address Word Address Format Notes Coil MB0.0-4095.F ------ DDDD.
6 Communication settings and guide of HMI connecting with controller Cable Diagram V series inverter MP2300 RS232 SGDM RS232 communication cable RS422 communication cable - 315 -
6 Communication settings and guide of HMI connecting with controller Ethernet communication protocol cable Cross-connection or crossover network cable can be used as communication cable via the hub or switch a. Cross-connection cable diagram b.
6 Communication settings and guide of HMI connecting with controller 6.
6 Communication settings and guide of HMI connecting with controller FA-M3 F3SP21-0N F3SP25-2N F3SP28-3N F3SP35-5N F3SP38-6N F3SP53-4H F3LE01-5T F3LE11-0T F3SP58-6H F3SP28-3S F3SP38-6S F3SP53-4S F3SP58-6S F3SP59-7S F3LE01-5T F3LE11-0T F3SP66-4S F3SP67-6S Ethernet I/F on CPU Unit Yokogawa FA-M3 Ethernet Serial System configuration Series FA-M3 CPU Link Module COM Type Parameter Cable F3SP21-0N F3SP25-2N F3SP28-3N F3SP35-5N F3SP38-6N F3SP53-4H F3SP58-6H F3SP28-3S F3SP38-6S F3SP53-4S F3SP58-6S F3
6 Communication settings and guide of HMI connecting with controller F3SP38-6N F3SP53-4H F3SP58-6H F3SP36-3N F3SP28-3S F3SP38-6S F3SP53-4S F3SP58-6S F3SP59-7S F3SP66-4S F3SP67-6S RS422/485(2Wire) port on F3LCLL-2F RS485 Setting Your owner cable Network System configuration Series FA-M3 CPU Link Module F3SP21-0N F3SP25-2N F3SP28-3N F3SP35-5N F3SP38-6N F3SP53-4H F3LE01-5T F3LE11-0T F3SP58-6H F3SP28-3S F3SP38-6S F3SP53-4S F3SP58-6S F3SP59-7S F3LE01-5T F3LE11-0T F3SP66-4S F3SP67-6S Ethernet I/F on
6 Communication settings and guide of HMI connecting with controller RS485-4 default communication: 19200, 8, 1, none; station: 1 PLC setting Set the 485 communication module on the right as below. 1. Transmission Speed Setting Switch: SW1=7 2.
6 Communication settings and guide of HMI connecting with controller 7 OFF Protect 8 OFF Always OFF 3. Station No. setting 1 4. Set the termination resistance switch of only the module which terminates the connection to 4WIRE RS485-2 default communication: 19200, 8, 1, none; station: 1 PLC setting Set the 485 communication module on the right as below. 1. Transmission Speed Setting Switch: SW1=7 2.
6 Communication settings and guide of HMI connecting with controller Network configuration PLC setting Use the swicthes on the right side of Ethernet module for setting the External Device. 1. Set all condition setup switch off. 2. Set IP Address: 192.168.100.230.
6 Communication settings and guide of HMI connecting with controller Output Relay Y (233~264)&(333~364) ------ DDD Input Relay X (201~232)&( 301~332) ------ DDD Special Register ------ Z_word 1~256 DDDD Link Register ------ W_word 1~256 DDD Index Register ------ V_word 1~64 DD File Register ------ B_word 1~256 DD Data Register ------ D_word 1~256 DDD Read only Cable Diagram RS232 Yokogawa programming cable RS485-4 HMI terminal 9pin D-SUB female/male Controller RS422 terminal
6 Communication settings and guide of HMI connecting with controller b. crossover network cable diagram HMI Ethernet terminal RJ45 1 TX+ (orange,white) 2 TX3 RX+ 4 BD4+ 5 BD46 RX7 BD3+ 8 BD3- (orange) (green,white) (blue) (blue,white) (green) (brown,white) (brown) Ethernet Hub or Switch RJ45 1 RX+(orange,white) 2 RX- (orange) 3 TX+ (green,white) 4 BD4+ (blue) 5 BD4- (blue,white) 6 TX(green) 7 BD3(brown,white) 8 BD3- (brown) 6.
6 Communication settings and guide of HMI connecting with controller Communication Setting RS485 default communication: 9600, 8, none, 1; station: 1 SPECIAL NOTE: For example: If station number is 2, register PV0.0 denotes channel 2, and PV1.0 denotes channel 3 (station number 2+main address 1). Thereinto the setting of station number is very important, it denotes start address of the controller (viz. instrument address in instrument parameter), and main address just denotes 4 channels.
6 Communication settings and guide of HMI connecting with controller dIH ------ 14 0EH -1999~+9999 DD ALP ------ 15 0FH 0~9999 DD Sc ------ 16 10H -1999~+4000 0.1℃ DD Op1 ------ 17 11H 0~48 DD oPL ------ 18 12H -110~+110% DD oPH ------ 19 13H 0~110% DD CF(Read Only) ------ 20 14H 0~127 DD ------ 21 15H 0~19.
6 Communication settings and guide of HMI connecting with controller AI-7048 Device Bit Address Word Address Format Notes PV ------ 0.0-3.0 D.D Read only SV ------ 0.0-3.0 D.D Reference ------ 0.0-3.86 D.D Reference Device Bit Address Word Address Format SP ------ 0 00H -1999-30000 DDD.DDD HIAL ------ 1 01H -1999~+9999 DDD.DDD LoAL ------ 2 02H -1999~+9999 DDD.DDD ------ 3 03H DDD.DDD ------ 4 04H DDD.DDD AHYS ------ 5 05H 0~2000 DDD.
6 Communication settings and guide of HMI connecting with controller controller, other controller can’t use address 5~8.