Radicom Research, Inc.
Table of Contents Introduction 3 Approvals Electronic Characteristics 4 4 Firmware Upgrade List 5 Model and Ordering Information 6 RB1000/ BPM1000FCE Mechanical Dimensions 7 RB1000/ BPM1000FCE Surface Module Pin Definitions RB1000/ BPM1000FCE Module Pin Descriptions 8 9 RB1000HM Mechanical Dimensions 10 RB1000HM Pin Descriptions 11 The AT Commands Layout Design Suggestions 12 14 FCC & IC Label and Model Identification 15 Important Regulatory Compliance and User Information 16 CE Decla
Introduction Thank you for choosing Radicom RB1000 family Module. We are committed to providing you quality service and technical support. The RB1000 modules are designed to meet OEM’s needs of embedding short-range, low power, wireless data connectivity to their products. The RB1000 family offers a quick and simple solution for wireless Bluetooth communications. The Radicom RB1000 family module is designed to meet the emerging market for Bluetooth 4.0 applications. These embedded Bluetooth 4.
Approvals ~ Pending • FCC Part 15: 47 CFR FCC Part 15 Subpart C 15.247, 47 CFR FCC Part 15 Subpart B 2009 (Class B) • IC RSS-102, IC ES-003 issue 4, IC RSS-210 issue 8:2010 • RoHS Compliant • CE Marked: EN 61000-3-2:2006+A2:2009, EN 62311:2008, EN 300 328 V1.7.1, EN 301 489-1, V1.8.1, EN 61000-3-3:2008, EN 301 489-17 V2.1.1, EN301 489-1 V1.9.
Firmware Upgrade List The list below reflects future application firmware that can be loaded into the RB1000 Family Acronym Description • ANP Alert Notification Profile • ANS Alert Notification Service • BAS Battery Service • BLP Blood Pressure Profile • BLS Blood Pressure Service • CTS Current Time Service • DIS Device Information Service • FMP Find Me Profile • GLP Glucose Profile • GLS Glucose Service • HIDS HID Service • HOGP HID over GATT Profile • HTP Health Th
Model and Ordering Information Model Numbers RB1000/ BPM1000FCE 0.57”x 0.99”x 0.12” surface mount, short range RB1000/BPM1000FCE Bluetooth module with on-board antenna 1.0” x 1.26” x 0.2” dual-in-line, through-hole Bluetooth module. RB1000HM RB1000 is mounted on Half Inch PCB for DIP (through-hole) interface to be RB1000HM.
RB1000/BPM1000FCE Mechanical Dimensions Module topside view: Board size = 14.5 mm x 25.2 mm (0.57” x 0.99”) Pitch = 1.14 mm (Left & Right side, 0.04”), 1.27mm (Down side, 0.05”) Pad width = 0.91 mm (0.
RB1000/BPM1000FCE Surface Mount Module Pin Definitions 8
RB1000/BPM1000FCE Module Pin Descriptions Pin # Pin Name Type Description I/O Voltage Range 1 GND - Ground - 2 VBAT PWR I Battery input and regulator enable (active high). 2.35V ~ 3.6V 3 WAKE PWR I Input to wake CSR1000 QFN from hibernate or dormant.
1 Voh: 0.75VDD Min 18 19 20 AIO (0) AIO (1) AIO (2) I/O Analogue programmable I/O line Input voltage: 0 – 1.3V I/O Analogue programmable I/O line Input voltage: 0 – 1.3V I/O Analogue programmable I/O line Input voltage: 0 – 1.3V 21 GND - - 22 GND - - 23 RF (Optional for External Antenna) RF I/O Bluetooth Transmitter / receiver - No Connection 2 3 RB1000HM Mechanical Dimensions 4 5 6 7 8 9 10 11 Notes: Pin spacing is 0.100 inch from center to center. Square pins - 0.025" x 0.
RB1000HM Pin Descriptions Pin # Pin Name Type 1 GND - 2 3 4 5 6 7 KEY AIO (1) AIO (0) N/C I/O I/O Description No Connections - No Pin – This Pin has been removed.
The AT Commands Using AT Commands for BLE Data Transfers - The RB1000 modules are defaulted to use the BLE Data Protocol and are controlled by Radicom’s proprietary AT Command set. For BLE Data Protocol operation, you need one Radicom Master and one Radicom Slave module. The Slave Model RB1000-S advertises or broadcasts the Bluetooth signal. The Master Model RB1000-M will scan for Bluetooth signals and then request a Bluetooth connection.
b) Issue the “atbp-c” command followed by the Bluetooth Address of the remote RB1000 “atbp-c00025b001510” to connect to Slave side. The Master side will display “Connecting 00025b001510” result code. c) If the Bluetooth connection is established, the “CONNECT” result code will be displayed on both sides. The RB1000 can now start sending data to each other. d) To send data from the Master issue “atbp-w12345” to send data “12345” (Up to 20 ASCII characters).
Layout Design Suggestions • General Layout Rules- All Printed Circuit Boards must comply with UL94V0 standard for flammability. Always use RoHS compliant Parts and materials. • Suggestions for Layout: 1. Do not place Power circuit, X’tal, Inductor, etc near RF area. 2. The bigger Antenna clearance area, the better. The Antenna itself needs to stay away from any circuit or component at least 3mm. Antenna clearance area means Top and Bottom both required to be cleared. 3.
FCC & IC Label and Model Identification The RB1000 module family is FCC Part 15 and IC (Industry Canada) certified. The RB1000 is also CE marked. The modules are labeled with the RB1000 module model number and FCC Part 15 ID, IC registration number and CE mark. The label can be found on top of the metal shielding on the RB1000 Module. Radicom Research Inc. Model: RB1000 FCC ID: K7T-RB1000 Radicom Research Inc. Model: RB1000HM FCC ID: K7T-RB1000 IC: 2377A-RB1000 IC: 2377A-RB1000 Radicom Research Inc.
Important Regulatory Compliance and User Information The final product with the modules installed needs to be tested for FCC Part 15, IC (Industry Canada) CE, EMI/RFI compliance. Radicom certification documentation will help streamline the final product approval process. Contact Radicom for more information. To maintain compliance in the finished product, carefully follow guidelines in this section.
End User Information This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. End users must follow the specific operating instructions for satisfying RF Exposure compliance. The end user should NOT be provided any instructions on how to remove or install the device. The user’s manual for end users must include the following information in a prominent location.
CE Declaration of Conformity For the following equipment: Radicom Research Inc. Bluetooth Module Model(s): RB1000,RB1000HM, BPM1000F are herewith confirmed to comply with the requirements set out in the Council (European parliament) Directive on the Approximation of the Laws of the Member States relating to Electromagnetic Compatibility of Radio and Telecom device (1999/5/CE). For the evaluation regarding this Directive, the following standards were applied: EN 61000-3-2:2006+A2:2009, EN 300 328 V1.7.
Limited Warranty Warranty Coverage and Duration Radicom Research, Inc. (“RRI”) warrants to the original purchaser its RRI-manufactured products (“Product”) against defects in material and workmanship under normal use and service for a period of one year from the date of delivery. During the applicable warranty period, at no charge, RRI will, at its option, either repair, replace or refund the purchase price of this Product, provided it is returned in accordance with the terms of this warranty to RRI.
What this Warranty does NOT Cover: (a) Defects or damage resulting from use of the Product in other than its normal and customary manner. (b) Defects or damage from misuse, accident or neglect. (c) Defects of damage from improper testing, operation, maintenance, installation, alteration, modification or adjustment. (d) Disassembly or repair of the Product in such a manner as to adversely affect performance or prevent adequate inspection and testing to verify any warranty claim.
Contacting Radicom Research If more information or technical support is needed, please contact us: 2148 Bering Drive San Jose, CA. 95131 Telephone: (408) 383 9006 Fax: (408) 383 9007 or e-mail: sales@radi.com http://www.radi.