System Manual RSN-iDEN-15-DC 2.2.6 High Power Amplifiers (HPAs) The High Power Amplifiers the transmitted signal from a base station at the final stage of the Booster and vice versa. R-tron Proprietary & Confidential Page 12 Issue: 1.
System Manual RSN-iDEN-15-DC 2.2.6 EMI Noise Filter 2.2.7 Communication & LED Board R-tron Proprietary & Confidential Page 13 Issue: 1.
System Manual RSN-iDEN-15-DC * Hardware Installation 1. Setting for Command and Control * iDEN MINI operates on a customer provided PC based platform with the following system requirements. Windows® XP Strong recommended 128 MB RAM or more Pentium Ⅲ processor or more keyboard RJ-45 jack Step 1 Open My Network Places. Step 2 Click the “View network connections”. R-tron Proprietary & Confidential Page 14 Issue: 1.
System Manual RSN-iDEN-15-DC Step 3 Push the right button of mouse and select the properties. Step 4 Click the properties of TCP/IP. R-tron Proprietary & Confidential Page 15 Issue: 1.
System Manual RSN-iDEN-15-DC Step 5 Set the values and OK as the following. Close all windows. Step 6 Open a new explorer window. R-tron Proprietary & Confidential Page 16 Issue: 1.
System Manual RSN-iDEN-15-DC Step 7 Type http://192.168.0.1:83 in the address box and press “Enter” key. Step 8 Login with “administrator” of ID and “1234” of password and “OK”. R-tron Proprietary & Confidential Page 17 Issue: 1.
System Manual RSN-iDEN-15-DC 2. Command and Control on the Web GUI. A. iDEN 800. a. To control the iDEN 800, check the box of iDEN 800. b. The operating bandwidth, 18MHz-bandwidth and 7MHz-bandwidth, is possibly selected. Select the operating bandwidth and push the “APPLY” and check the bandwidth. R-tron Proprietary & Confidential Page 18 Issue: 1.
System Manual RSN-iDEN-15-DC c. The operating frequency is able to be selected. Select the operating frequency and push the “APPLY” and check the bandwidth and frequency. R-tron Proprietary & Confidential Page 19 Issue: 1.
System Manual RSN-iDEN-15-DC B. iDEN 900. a. To control the iDEN 900, check the box of iDEN 900. b. On the iDEN 900, 5MHz-bandwith is only available. Select the operating frequency and push the “APPLY” and check the bandwidth and frequency. R-tron Proprietary & Confidential Page 20 Issue: 1.
System Manual RSN-iDEN-15-DC C. DL and UL gain setting. a. Set the DL gain and UL gain, 50dB to 80dB, and push the “APPLY” button. * Set the gain of iDEN 900 as same as the iDEN 800 gain setting. R-tron Proprietary & Confidential Page 21 Issue: 1.
System Manual RSN-iDEN-15-DC D. HPA on and off. a. Press the “ON” and “OFF” and check the status. The maximum output power for operating is +25dBm on both DL and UL. R-tron Proprietary & Confidential Page 22 Issue: 1.
System Manual RSN-iDEN-15-DC * Reference The Operating Bandwidth & Frequencies Bandwidth Operating Frequency 851~869MHz Downlink 851~868.8MHz 851~868.6MHz 18MHz-bandwidth 806~824MHz Uplink 806~823.8MHz 806~823.6MHz iDEN 800 862~869MHz Downlink 862~868.8MHz 862~868.6MHz 7MHz-bandwidth 817~824MHz Uplink 817~823.8MHz 817~823.6MHz 935~940MHz Downlink iDEN 900 935~939.8MHz 935~939.6MHz 5MHz-bandwidth 896~901MHz Uplink 896~900.8MHz 896~900.