OWNER’S GUIDE SMART ATTIC GABLE FAN AFG SMT PRO-2.0 ! AFG SMT PRO-3.0 DO NOT THROW AWAY! AFG SMT ES-3.0 SERIAL NUMBER FOR FAN IS LOCATED ON THE BACK COVER OF THE OWNER’S GUIDE.
CONTENTS 1. SYSTEM OVERVIEW. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 1.1 Introduction. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 1.2 Features. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 1.3 System Venting Requirements. . . . . . . . . . . . . . . . . . . . . . . . . . . 4 2. INSTALLATION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 2.
1. SYSTEM OVERVIEW INTRODUCTION WELCOME 1.1 CONGRATULATIONS on the purchase of your new QuietCool Smart Attic Fan! INSTALLATION QuietCool Attic Fans are the best in the business.
1.3 SYSTEM VENTING REQUIREMENTS ! VERY IMPORTANT: 1 SQUARE FOOT OF NET FREE VENT AREA PER 750 CFM ! RECOMMENDED: 2 TO 4 SQUARE FEET OF INLET VENTS PER FAN Venting plays a very significant role in the performace of QuietCool fans. QuietCool recommends a minimum of 1 SQ. FT. of venting for every 750 CFM in the QuietCool system. If an attic has at least 1:750 attic venting, the QuietCool system will operate efficiently and effectively.
2.1 INSTALLING ATTIC GABLE FAN ! Installation Video: Watch the video by scanning the QR code or visit www.QuietCoolSystems.com/support WELCOME 2. INSTALLATION NOTE: The AFG model fans are designed to mount behind existing vents. If no vent exists, one must be installed. Vent should be installed in the upper center section of the gable. 1. Installing the QuietCool AFG is very easy.
2.2 INSTALLING AFG VENT COVERS Installation Video: Watch the video by scanning the QR code or visit www.QuietCoolSystems.com/support Included with your QuietCool Attic Gable Fan are four vent covers that are designed to be installed around the attic fan housing to block any air backdrafting into the attic through a gable vent that is larger than the attic fan cylinder, causing air to cycle in and out around the vent. Figure 2.1A 1.
! ! WELCOME 3. WIRING IMPORTANT: Wiring Diagrams are for examples ONLY. Wiring should be done by a licensed electrician following local building and electrical codes and/or NEC guidelines. NOTE: Your fan came with the Smart Control Hub pre-wired to a power cord for testing purposes before installation. If you would like to hard-wire the fan, or it is required by your local building codes, please follow the wiring instructions below. 3.1 TWO SPEED WIRING - (AFG SMT PRO-2.0 & AFG SMT PRO-3.
3.2 THREE SPEED WIRING - (AFG SMT ES-3.0) 1. Using a wire nut, connect the black wire from the power cord and the black wire from the fan to the black wire from the Hub. 2. Connect the white wire from the power cord and the white wire on the fan to the white wire from the Hub. 3. Connect the red wire from the fan to the red wire on the Hub 4. Connect the yellow wire from the fan to the yellow wire on the Hub 5. Connect the blue wire from the fan to the blue wire on the Hub 6.
• Temp and Hum | Timer Indicator • This LED indicator will light up as shown below: • Blinking: Timer Mode Active • Solid: Smart Mode Active • Test Indicator • The Test LED indicator will light up as shown below when the Test button is pressed: • Two Speed Fan: blink three times every 2 seconds on HIGH, blink once every 2 seconds on LOW • Three Speed Fan: blink three times every 2 seconds on HIGH, blink twice every 2 seconds on MED, blink once every 2 seconds on LOW • Pair Indicator • The Pair LED indi
4. SYSTEM OPERATING INSTRUCTIONS 4.1 DOWNLOADING THE QUIETCOOL SMART CONTROL APP Download the QuietCool Smart Control App onto your iOS or Android device. Scan the QR code above or visit QuietCoolSystems.com/smart-control/ and click the link to download the app to your device. 4.2 OPERATING THE QUIETCOOL SMART CONTROL APP HOME PAGE This is the home page of the app and is presented as soon as the app is opened. If you have not yet paired your phone to your Hub, it will state SETUP REQUIRED.
WELCOME FAN CONTROL PAGE This page is accessed when you tap on your fan from the Home Page. INSTALLATION On this page you can see the current conditions in your attic, activate the different modes of the fan, and get to the Fan Settings page. WIRING FAN SETTINGS PAGE This page is used to adjust the settings of the fan. OPERATION You can quickly change the Fan Name, check if the speeds are set properly, change the Fan Model, enter the Serial Number and adjust the Climate Settings & Presets.
SETTING UP YOUR FAN Once your attic fan has power, open up the QuietCool Smart Control app. You will be taken to the Home Page. You should see your attic fan show up in the list of available fans. A message indicates that setup is required. Press and hold the Pair button on the Hub until the LED indicator begins to blink. ! NOTE: You will need to initiate this Pairing process on each device you want to use to control your attic fan.
WELCOME TEMPERATURE The settings you choose in this section will change what temperature the fan will come on at each set speed. • Tap on any speed to adjust the temperature for each speed. INSTALLATION • HUMIDITY • Turn Fan On: This is the humidity percentage that will cause the fan to turn on, regardless if the temperature settings are not met.
FAN CONTROL PAGE On the Fan Control page, you will see the current fan status, the current attic temperature, as well as the current attic humidity level. You also have the option to Activate Smart Mode or Activate Timer Mode. You can also go into the Fan Settings page and adjust the settings that you setup in the first step. TIMER MODE Timer Mode is a simple way to turn your attic fan on for a set amount of time at a set speed. To activate Timer Mode, simply tap Activate Timer Mode.
WELCOME SMART MODE Smart Mode will automatically change the speed based on the attic temperature and humidity. INSTALLATION To activate Smart Mode, simply tap Activate Smart Mode. WIRING In Smart Mode, the first paramater that is checked is the Turn Fan Off humidity level. Regardless of the temperature in the attic, if the Humidity level in the attic is above the Turn Fan Off humidity setting, the fan will not turn on, or if it is already running, the fan will shut off.
PAIR MODE Pair Mode is a feature that was designed to prevent users from having to get into the attic to access the physical Hub in order to pair additional devices. ! NOTE: In order to use this feature, you must have one device that is already paired to the Fan Hub. If you do not have any devices that are currently paired to the Fan Hub, you will have to press the physical Pair button. In the Fan Settings page, tap Enter Pair Mode.
WELCOME FIRMWARE UPDATE Your attic fan includes a Firmware Update feature in order for us to update your Fan Hub to include bug fixes and additional features in the future. INSTALLATION We recommend checking for a new firmware update a few times per year. To check for an available firmware update, go into the Fan Settings page and tap Firmware Update. WIRING If there is no update available, an alert will popup indicating there is no available firmware update.
4.3 FREQUENTLY ASKED QUESTIONS WHAT PROTOCAL DOES THIS CONTROL USE? This control operates over Bluetooth to connect to your phone. The control uses Wi-Fi for firmware updates. WILL MY NEIGHBOR BE ABLE TO CONTROL MY FAN IF THEY HAVE THE SAME SET UP AS ME? No. In order to connect to your Smart Attic Fan Control Hub, you must first pair your device by using the Pair button on the Hub.
WELCOME INSTALLATION WIRING OPERATION WARRANTY 19 QUIETCOOLSYSTEMS.
1-888-QUIETCOOL
WELCOME INSTALLATION WIRING OPERATION WARRANTY 21 QUIETCOOLSYSTEMS.
ATTIC GABLE FANS LIMITED WARRANTY This warranty is extended to the original purchaser of this model or, if this unit is purchased and requires installation by a building contractor, to the original owner of the home. No subsequent purchaser of the unit or of a home in which it is installed is entitled to any of the benefits of this warranty. The QuietCool Product that you have purchased has a limited warranty from the date of purchase against defects in workmanship and materials.
WELCOME ATTIC GABLE FANS LIMITED WARRANTY Motor Replacements INSTALLATION The electrical motor is to be used solely as a direct replacement for a motor of the same model in QC Manufacturing, Inc., QuietCool products. Using the motor in any other product could result in electrical shock and/ or fire, which may cause property damage, serious injury or even death.
Rev. 9/26/22 FAN SERIAL NUMBER INFORMATION RETAIN FOR YOUR RECORDS. SERIAL NUMBER IS REQUIRED FOR WARRANTY PURPOSES. 1-888-QUIETCOOL | WWW.QUIETCOOLSYSTEMS.