Instructions / Assembly

2000
Kickspace Heater Series
INSTALLATION
OPERATING
MAINTENANCE
QUIET-ONE
Models:
KS 2004, KS 2006
KS 2008, KS 2010
Please read these instructions thoroughly before beginning your installation!
Smiths Quiet-One 2000 Series kickspace heaters are designed for installation in a forced hot water (hydronic) heating system. They may
also be used with conventional gas, oil, electric, or solar powered water heaters.
IMPORTANT: BEFORE INSTALLING ANY HEATING TERMINAL UNIT TO A DOMESTIC WATER
HEATER, CONSULT THE LOCAL PLUMBING CODES.
When installing a kickspace heater, an accurate heat loss calculation of the space is required. Match unit selection with BTUH output at
system water temperature and flow rate. See the capacity chart below for output at various water temperatures and flow rates.
NOTE: All kickspace heaters include a low limit aquastat which shuts off power to the fan when water temperature falls to 110
o
F. Power
is restored when water temperature rises to 130
o
F. When installing units with low temperature systems (radiant or water heater), it may
be necessary to change the aquastat to a special (90
o
/110
o
F) low temperature unit (part #S10046).
UNIT INSPECTION
Before starting the installation, carefully remove the kickspace heater from its box. Inspect for any damage caused in handling. The box
should include:
(1) Kickspace unit
(2) Molded grille endcaps (KS 2004 only)
(2) Mounting screws
(2) Screw covers
LOCATING THE KICKSPACE HEATER
Quiet-One 2000 Series kickspace units are designed for installation under kitchen cabinets, bathroom vanities, built-in shelves or benches,
and stairways. An available recessed wall mounting kit enables vertical installation with a flush mounted grille. Consideration should be
given in regards to perishable goods stored in the cabinet above the unit.
Environmental Products
Flow Rate
Pressure
GPM Drop (ft) 130 140 150 160 170 180 190 200 210
1 .06 2095 2410 2700 3000 3350 3650 3860 4000 4105
KS 2004 3 .422 2240 2650 3000 3350 3765 4350 4350 4530 4635
5 1.026 2350 2755 3140 3530 3940 4590 4590 4810 4935
1 .12 3410 4050 4655 5265 5860 6700 6700 7110 7270
KS 2006 3 1.19 3735 4395 5060 5735 6330 7120 7120 7530 7790
5 2.6 3860 4540 5225 5910 6560 7415 7415 7800 8010
1 .12 4300 5000 5765 6500 7370 8400 8400 8735 8920
KS 2008 3 1.19 4580 5380 6195 7050 7930 9010 9010 9445 9740
5 2.6 4760 5625 6450 7290 8200 9360 9360 9785 10020
1 .41 5530 6350 7150 7975 8780 9975 9975 10330 10520
KS 2010 3 2.78 5880 6710 7740 8710 9625 11060 11060 11530 11740
5 3.92 6070 7030 8000 9030 10025 11525 11525 11995 12180
Entering Water Temperature (in degrees F) - BTU/hrs.
Unit
All capacities are rated by RTS with the kickspace installed under a cabinet and all capacities include the heat effect factor.
For low speed ratings use: .85 for the KS2004, .75 for the KS2006, .70 for the KS2008 and .65 for the KS2010.
Heat throw: KS2004 = 10@ 50 CFM; KS2006 = 10@ 75 CFM; KS2008 = 10 at 90 CFM; KS2010 = 10 @ 125 CFM.

Summary of content (5 pages)