Quanta Microsystems Inc.
Quanta Microsystems, Inc. Subject: Doc No. ZM100 operation manual-RF mode Revised Date: OP_ZM100-1 2007/05/16 Rev: Page: Reason for Release: Revision Effective Date Author 0.1 05/16/2007 Samuel Wang Description of Changes First draft QMI PROPERTY & CONFIDENTIAL! 2 0.
Quanta Microsystems, Inc. Subject: Doc No. 1. ZM100 operation manual-RF mode Revised Date: OP_ZM100-1 2007/05/16 Adaptor board connection and setup Power IN (+3.3Vdc) USB plug in: ― J_USB should be selected as USB PWR IN mode ― USB +5V Æ LDOÆ+3.3V RCA Jack plug in: ― J_USB should be opeded ― Use a +3.3V(inner) DC adaptor plug in CON_RCA Pin header plug in: ― Use other power source(such as power supply) ― Supply +3.3V and plug in by J_RCA pin header Fig1.
Quanta Microsystems, Inc. Subject: Doc No. ZM100 operation manual-RF mode Revised Date: OP_ZM100-1 2007/05/16 UART connection Use a D-SUB9 cable connects to PC com port Open OS hyper terminal as a com port used Set properties as following Fig 1.1 Hyper terminal COM port settings QMI PROPERTY & CONFIDENTIAL! 4 Rev: Page: 0.
Quanta Microsystems, Inc. Subject: Doc No. ZM100 operation manual-RF mode Revised Date: OP_ZM100-1 2007/05/16 Fig 1.2 Hyper terminal Properties settings QMI PROPERTY & CONFIDENTIAL! 5 Rev: Page: 0.
Quanta Microsystems, Inc. Subject: Doc No. ZM100 operation manual-RF mode Revised Date: OP_ZM100-1 2007/05/16 Rev: Page: 0.1 6 of 9 Fig 1.3 ASCII setup After finished above item, connect DUT and adaptor board by 6pin wire connection.
Quanta Microsystems, Inc. Subject: Doc No. 2. ZM100 operation manual-RF mode Revised Date: OP_ZM100-1 2007/05/16 RF test mode application Channel selection Set channel ― Select character “1,2,3….,f,g to set channel 1~16 QMI PROPERTY & CONFIDENTIAL! 7 Rev: Page: 0.
Quanta Microsystems, Inc. Subject: Doc No. ZM100 operation manual-RF mode Revised Date: OP_ZM100-1 2007/05/16 Set output power ― Default power: -0.66dBm (select character “n”) QMI PROPERTY & CONFIDENTIAL! 8 Rev: Page: 0.
Quanta Microsystems, Inc. Subject: Doc No. ZM100 operation manual-RF mode Revised Date: OP_ZM100-1 2007/05/16 Rev: Page: 0.1 9 of 9 Set operation mode ― Select character “v,w,x…r,s” for operation mode After you finished testing, you can select character “t” to go back to main manual. If you can not go back to main manual (ex. DUT on sleep mode); it shall be power off then power on DUT to go back to main manual.
Statements of FCC, IC, CE, Federal Communication Commission Interference Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
End Product Labeling This transmitter module is authorized only for use in device where the antenna may be installed such that 20 cm may be maintained between the antenna and users. The final end product must be labeled in a visible area with the following Contains: “FCC ID:T5U-ZM100”.