QUALCOMM CONFIDENTIAL AND PROPRIETARY | INTERNAL USE ONLY | RESTRICTED DISTRIBUTION Feb.
Qualcomm Confidential and Proprietary Restricted Distribution. Not to be distributed to anyone who is not an employee of either Qualcomm or a subsidiary of Qualcomm without the express approval of Qualcomm’s Configuration Management. Not to be used, copied, reproduced in whole or in part, nor its contents revealed in any manner to others without the express written permission of Qualcomm.
•Terms and Conditions of Usage This document contains descriptions of parts whose manufacture, use, sale, offer for sale, or importation into the United States is limited or prohibited by the February 5th, 2008 injunction against QUALCOMM Incorporated. This document should not be construed as an offer to sell such parts for use or importation into the U.S., nor should it be construed as assistance in making, using, selling, offering to sell, or the importation of any product in the U.S.
Table of Contents # Section Page 1 Introduction 5 2 Getting Started 6 3 Jumpers and Switches 7 4 Cables Connections 8 5 Power Supply Connection 9 6 Module Powering Up/Down 10 7 Ground Pin 11 8 Standards 12 9 Regulatory Compliance 13 PAGE 4 | QUALCOMM CONFIDENTIAL AND PROPRIETARY | RESTRICTED DISTRIBUTION
Castra without Zigbee Module Introduction Internal LED Castra with out Zigbee EDK enables 3rd party users to build and perform on-target development and testing The EDK kit includes: Power Key Power Button Module Fixture Battery Port Castra without Zigbee module SIF Connector USB Port Module fixture RF Port Accessories – µUSB cable – Battery emulator Accessories cable Battery Emulator cable PAGE 5 | QUALCOMM CONFIDENTIAL AND PROPRIETARY | RESTRICTED DISTRIBUTION µUSB cable
Getting Started 1. Insert the module to the fixture with the JTAG test points pointing upward (as seen in the pictures below) 2.
Jumpers and Switches 3.
Cables Connections 4.
Power Supply Connection 5. Battery Emulator Cable (MCN: 45-A6453-C50 ) (connected to a power supply) – Allows reproducible testing results (since the voltage doesn’t change) PAGE 9 | – – Allows endless operation for long tests – Use a power supply with reverse current abilities to support charging operation when the USB cable is connected When a battery cable is used set the power supply for 3.
Module Powering Up/Down 6. In order to power up the module: – Connect the battery emulator cable to the fixture battery port – Connect the µUSB cable to the fixture USB port » The module shall be powered on and the internal LED light shall be constantly GREEN – If the µUSB cable is not connected, press the Power Button for 3 seconds until the LED blinks shortly in GREEN. From that point the LED should blink periodically every 5 seconds 7.
Ground Pin 8. When external test equipment requires ground connection (e.g.
Standards Standards and Certification The Castra without Zigbee module conforms to the following standards and certification requirements: CDMA TIA/EIA IS-98E (CDMA2000 1x) FCC 47 CFR Part 1 – RF radiation exposure limits 47 CFR Part 2 – Equipment authorization 47 CFR Part 15 – Intentional and unintentional radiators 47 CFR Part 22 – Cellular 47 CFR Part 24 - PCS PAGE 12 | QUALCOMM CONFIDENTIAL AND PROPRIETARY | RESTRICTED DISTRIBUTION
Regulatory Compliance Safety Warnings Do not operate the Castra without Zigbee module in the following environments: In active blasting areas. In potentially explosive environments such as refueling points, fuel depots or chemical plants. Near medical equipment, especially life support equipment that might be susceptible to radio interference. In an aircraft. The Castra without Zigbee module transmissions could interfere with aircraft electrical and communication systems.
Regulatory Compliance The Castra without Zigbee module has been approved for mobile applications in the United States. Additional FCC certification is not required by host devices as long as the following conditions are met: Maintain at least 20 cm separation between the antennas and the user’s body. Maximum antenna gain (including cable loss): Cellular band < 7 dBi PCS band < 4 dBi Independent Castra without Zigbee module operation.
Regulatory Compliance which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician to help.
Thank you! QUALCOMM CONFIDENTIAL AND PROPRIETARY PAGE 16 | INTERNAL USE ONLY | RESTRICTED DISTRIBUTION