HPRO-4G PLS-63W Certification Users’ Guide Document # 1193-30xx Revision SENSITIVITY LEVEL: YELLOW Document Number 1193-30xx This document contains confidential and proprietary information of Quake Global corporation. It may be used by recipient only for the purpose for which it was transmitted and will be returned upon request or when no longer needed by recipient. Disclosure to unauthorized third parties or duplication without the express written permission of Quake Global is prohibited.
Quake Test Application Users’ Guide HPro-4G Revision History DATE REV ECO# REASON 10/11/2018 A 02498 Initial release 10/23/2018 B 02516 Application installation instructions and ip67 test instructions added. Added instructions on assigning a static IP address. Added set up instructions for PLS63-W testing.
Quake Test Application Users’ Guide HPro-4G Table of Contents 1 INTRODUCTION ............................................................................................................... 4 1.1 Prerequisites ................................................................................................................................... 4 1.1.1 1.1.2 2 Available from Quake ............................................................................................................................
Quake Test Application Users’ Guide HPro-4G Table of Figures Table of Tables Confidential Table 1 Quake Provided Support Equipment ............................................................................................................... 4 Document Number 1193-30xx Page iii This document contains confidential and proprietary information of Quake Global corporation.
Software Specification 1 Introduction The HPRO set up instructions demonstrates basic functionality of the HPRO device. With these steps the user can test functionality of the various hardware functions and features. The primary purpose of these instructions is to assist with the following: • • • CE/FCC Testing Cellular Testing Reliability and Environmental Testing This User’s Guide describes the following activities: • • • Connecting the device to support equipment.
Software Specification 2 Setup The following instructions will describe the very basic hardware and software setup of the device and connection to minimal support equipment elements. 2.1 Hardware The Terminal requires, two connections, an antenna connection, consisting of GNSS antenna and, connection to a power source and communication interface via the supplied interface cable. The evaluation kit provides the appropriate interface cable and antenna for these connections.
Software Specification 2.1.1 Terminal Setup The terminal may be used with a serial connection, and/or an Ethernet Connection. Both methods are described here. Quake recommends the Serial Connection method due to its simplicity. Users running QConnectATECerts with a desire to operate the Ethernet connection will need to initially connect via a Serial Connection to enable the Ethernet interface.
Software Specification When TeraTerm launches, select ‘Serial’ in the connection dialog and the appropriate adapter from the dropdown dialog box. Figure 3 Create Connection Information classified Confidential - Do not copy. Confidential From the Setup -> Serial Port… menu item in Tera Term, set the port to 115200kbps and 8 bits, 1 stop bit. Figure 4 Set Baud Serial Port Configuration Turn on the power supply or connect to an external battery.
Software Specification 2.1.1.2 Option 2: Ethernet Connection (Do not perform if serial connection used) Configuring for an Ethernet application requires the additional step of setting the host static IP address. While the terminal is provisioned with a static IP address, the host PC will need a static IP address. Follow the instructions below to set a Windows host with a static IP address. 2.1.1.2.
Software Specification Locate the Ethernet adapter you intend to connect the device to, right-click and select ‘Properties’. Locate and select the ‘Internet Protocol Version 4 (TCP/IPv4) settings and click ‘Properties’ Information classified Confidential - Do not copy. Confidential Figure 7 Adapter Properties Figure 8 IPv4 Settings Document Number 1193-30xx Page 9 This document contains confidential and proprietary information of Quake Global corporation.
Software Specification Figure 9 Setting the IP Address The Windows host now has a static IP address. 2.1.1.2.2 Establishing the Connection with Tera Term Connect the RJ45 Ethernet cable from the device to the host PC with a static IP address as shown above. Turn the supply ‘ON’ or make the final battery connection to power the unit ON. Wait approximately 30 – 60 seconds for the device to complete its boot process before continuing.
Software Specification Figure 10 Create Connection Information classified Confidential - Do not copy. Confidential If you receive the prompt below, everything appears to be properly configured and you’ve waited 60-90 seconds, you may need to manually enable the Ethernet port using the Serial Connection. Figure 11 Connection Refused Document Number 1193-30xx Page 11 This document contains confidential and proprietary information of Quake Global corporation.
Software Specification 2.1.1.2.3 Enabling Ethernet If you are receiving ‘Connection refused’ as shown above it’s likely your device is running a variant of the Test App which, by default, leaves the Ethernet port OFF. To turn it on, first, connect via the Serial Port using the instructions: Option 1: Serial Connection. 1. Edit /etc/network/interfaces file, file contents should look similar to: vi /etc/network/interfaces Information classified Confidential - Do not copy.
Software Specification and then ./S50sshd restart Then connect to ssh and paste a message related to the picture Depending on the type of testing, support equipment may, or may not be required.
Software Specification 3 FCC 15b Testing Figure 12 FCC part 15b setup Ensure you have Tera Term installed on a laptop and follow the instructions for ether Option 1: Serial Connection or Option 2: Ethernet Connection. Document Number 1193-30xx Page 14 This document contains confidential and proprietary information of Quake Global corporation.
Software Specification 4 Testing This section describes setting up the device for testing Cell, Wi-Fi, BT and GPS. 4.1 Cell Testing - Sending AT Commands Connect to the device using terminal software in Serial mode Option 1: Serial Connection At the login prompt, enter ‘root’ for user and ‘certs’ for password (without quotation marks). Information classified Confidential - Do not copy. Confidential • Open Ethernet port on Tera term, by clicking on file , then click new connection.
Software Specification (Any other desired AT commands can be entered from microcom mode) Ctrl+’x’ to quit microcom mode Information classified Confidential - Do not copy. Confidential Connect call box, run tests 4.2 GPS Testing • Open Ethernet port on Tera term, by clicking on file , then click new connection. 1)Host:root@192.168.35.
Software Specification Type: • gpsmon Information classified Confidential - Do not copy. Confidential It should show an image like this: 4.3 Wi-Fi Testing • Open Ethernet port on Tera term, by clicking on file , then click new connection. 1)Host:root@192.168.35.10 and service : SSH 2)Click ok Document Number 1193-30xx Page 17 This document contains confidential and proprietary information of Quake Global corporation.
Software Specification 3)User Name: root 4)password:certs If connection is failing type on TeraTerm serial: ifup - a Return to ethernet window and repeat steps 1 and 2 5)type: ls Preparation: Make sure that wifiTest is available in the list of application installed by typing ‘ls’ If the device does not have the wifiTest file, please contact Quake Global. This script should only be run once. Navigate to the ‘root’ directory (default location after login/pass).
Software Specification Condensed version with an example of the output: Low Channel: linux prompt>>./wifiTest inter >start >cOn >cCh 1 0 0 >cPow 16500 0 >cTxOn 0 0 EXPECTED OUTPUT: Calibrator:: Starting TX Simulation (delay=200, rate=13, size=500, mode=0 data_type=0, BW=0, gi=1, opt1=0x0, opt2=0x0 src=00:11:22:33:44:55 dst=01:02:03:04:05:06)...
Software Specification data_type=0, BW=0, gi=1, opt1=0x0, opt2=0x0 src=00:11:22:33:44:55 dst=01:02:03:04:05:06)... >cTxOff To change between channels: linux prompt>>./wifiTest inter EXPECTED OUTPUT: Calibrator:: Starting TX Simulation (delay=200, rate=13, size=500, mode=0 data_type=0, BW=0, gi=1, opt1=0x0, opt2=0x0 src=00:11:22:33:44:55 dst=01:02:03:04:05:06)...
Software Specification 4.4 BT testing • Open Ethernet port on Tera term, by clicking on file , then click new connection. 1)Host:root@192.168.35.10 and service : SSH 2)Click ok 3)User Name: root 4)password:certs Type: • • • cd /usr/share/wl18xx/ ./btup.sh ./bt_test.sh -c 1 -t This will start a Bluetooth transmit test in channel 1, bt_test is a bash script with the following options: Usage: ./bt_test.sh -c [channel] [ -t | -r ] Bluetooth Transmit on 2.
Software Specification CONFIDENTIALITY OBLIGATIONS This document contains sensitive information and is classified “CONFIDENTIAL”. Its distribution is subject to the recipient’s signature of a Non-Disclosure Agreement (NDA). At all times you should comply with the following security rules (Refer to the NDA for detailed obligations): This document may not be altered in any way that removes or obscures the Confidentiality notices. Keep this document locked away.