Z-Wave Automated Roller/Honeycomb Shade Operation Manual For model numbers QMRS-908-3, QMRS-908-4, QMRS-908-6, QMRS-908-8, QMHCS-908-4, QMHCS-908-6 FCC/IC IDs FCC ID: 2AHG4-QMRS-908, IC: 21161-QMRS-908 FCC ID: 2AHG4-QMHCS-908, IC: 21161-QMHCS-908 Revision G 3/24/2016 1
TO OUR CUSTOMER It is our mission to bring you a high quality product that fits our high standards for innovation, beauty and simplicity. To do so we have released our Second Generation QMotion® Automated Roller Shade to bring you a great shade experience. This design has many features that you may or may not have noticed that will make your shade more reliable and ready for our future development plans.
Table of Contents Z-Wave Specifications …………………………………….…………………………….…………………...4 Z-Wave Programming Instructions……………………...……………………………….………………….5 Glossary………….……………………………………………………………………….……………………8 Regulatory Information………………………………………………………………….………………..….. 9 Revision History... ……………………………………………………………………….………………..
Qadvanced Roller Shade Z-Wave Z-Wave Specifications Z-Wave® is a registered trademark of Sigma Designs Inc. and/or its subsidiaries. This product can be included and operated in any Z-Wave network with other Z-Wave certified devices from other manufacturers and/or other applications. All non-battery operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network.
Qadvanced Roller Shade Z-Wave Programming Instructions IMPORTANT Read and understand each section before performing required steps During FIRST TIME SETUP after Step 3. TUG, a Z-Wave Plus controller must be paired to the shade within 90 seconds. Otherwise, the shade will time-out and require another attempt. JOG is a short up and down movement. A double JOG from the current position will indicate failure on the device add.
IMPORTANT Lower Limit Position should be set after the first ADD of the device by using the FIRST TIME ADD procedure. The double job action is an indication of failure and the process is aborted. If the expected results differ or a failure is indicated, restart the calibration process. SHADE CALIBRATION (setting lower limit) 1. Now perform two micro tugs, short pause between them. __ (Shade will move to Upper Limit Position, then down a small amount) 2.
Z-Wave Operating Notes TUG COMMAND MODES 1. Tug hem bar 2 times within 800ms to enter command mode 2. Shade responds to signal command mode entry (Jog**) 3. Shade will time-out after 5 seconds of inactivity and perform command failure response (Jog**) 4. Once Shade enters command mode, perform additional Taps/Tugs to send commands A. Add/Remove shade —1 additional B. Calibrate — 2 additional C. Battery Change Mode — 4 additional D. Z-Wave Reset — 6 additional E.
Glossary Fascia The removable covering that hides the internal shade components and battery holder. Long Tug Tug shade hembar more than 2 inches. A long tug will cause the shade to stay at the position it was tugged to. Two long tugs done within 10 seconds of each other will send the shade to the upper limit position. Micro Tug Tug shade hembar up to 1 inch. A micro tug will send the shade to the next highest position Short Tug Tug shade hembar 1 to 2 inches.
REGULATORY INFORMATION FCC & IC Notice This device complies with Part 15 of the FCC Rules and Industry Canada license exempt standard(s). Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference received that may cause undesired operation. Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio exempts de licence.
Revision History Revision A - 2/03/16: Created Revision B - 2/08/16: Modified Revision C - 2/16/16: FCC/IC, Address info, misc.