AD-210 Owner’s Manual VGA/DVI to DVI Converter/Scaler w. PIP Dtrovision LLC 9A Bergen Turnpike Little Ferry, NJ 07643 Tel: 201.488.3232 Fax: 201.621.6118 E-mail: mpark@dtrovision.com www.purelinkav.com www.dtrovision.com For technical support, contact: support@dtrovision.
PureLink by Dtrovision Table of Contents 1-1 Package Contents p.3 1-2 General Specification p.4 1-3 Operation and Reliability Specifications p.6 1-4 Main Features p.7 1-5 Technical and Mechanical Specification p.8 1-6 External Design p.10 1-7 How to use Menu Option p.11 1-8 Connector Pin Assignment p.20 1-9 Command Protocol p.21 1-10 Warranty p.
PureLink by Dtrovision 1-1 Package Contents Please make sure all of the following items are included in the package: 1) AD-210 2) Power Supply Adapter(DC 12V) 3) AC Power Cord 4) USB Cable 5) User Manual 3
PureLink by Dtrovision 1-2 General Specification PureLink’s AD-210 signal conversion UP/Down scaler product is a high performance analog & DVI to DVI scaler that converts incoming analog RGB and YPbPr signal to DVI signal. In addition to conversion, AD-210 is capable of UP/Down scaling DVI input resolution as well as DVI output resolution. AD-210 supports the resolution from VGA to WUXGA, 60Hz~85Hz.
PureLink by Dtrovision Power Consumption 9W Max Unit Dimension 7.4 x 6.7 x 1.7 Inch Weight 2.
PureLink by Dtrovision 1-3 Operation and Reliability Specification 1. Operating Environment Temperature : 50F ~ 104F (10℃~ 40℃) Humidity : 10% ~ 80% Altitude : 3,000m Max. 2. Transit Environment Temperature : -13F ~ 140F (-25℃~ 60℃) Humidity : 5% ~ 95% Altitude : 15,000m Max. 3. Storage Environment Temperature : -4F ~ -49F (-20℃~ 45℃) Humidity : 5% ~ 95% Altitude : 3,000m Max. 4.
PureLink by Dtrovision 1-4 Main Features *High Quality Picture – No Signal Loss and Support wide range of video resolution AD-210 is designed with one of the highest quality scaling IC which offers various effective function, such as quickly and reliably convert analog (RGB & YPbPr) and DVI signal to HD digital (DVI/HDMI) signal and put UP/Down the resolution on both VGA&DVI input and DVI output port. At the same time, the digital noises that may affect the picture quality will be eliminated.
PureLink by Dtrovision 1-5 Technical Specification Input Signal Characteristics Input Signal DC input VGA input (15Pin DDetailed) Description Unit Min Typical Max DC Voltage VDC 11.5 12 12.5 Power Consumption Watts 7.2 7.8 8.8 Video Vp-p 0.714(1.0) Sync Voltage Vp-p 5.
PureLink by Dtrovision 1.2 DVI (HDMI) Timing Chart - Auto Time Set - 1920*1080p 50Hz - 720*483p 59.94Hz - 1920*1080p 59.94Hz - 1280*1024 85Hz - 720*576p 50Hz - 1920*1080p 60Hz - 1360*768 60Hz - 1280*720p 50Hz - 800*600 60Hz - 1366*768 50Hz - 1280*720p 59.94Hz - 800*600 75Hz - 1400*900 60Hz - 1280*720p 60Hz - 1024*768 60Hz - 1600*1200 60Hz - 1920*1080i 25(50)Hz - 1024*768 75Hz - 1920*1200 60Hz - 1920*1080i 29.7(59.
PureLink by Dtrovision 1-6 External Design Dimension (W * D * H): 7.4 x 6.7 x 1.
PureLink by Dtrovision 1-7 How to use Menu Option 1. Operation Manual (OSD View) - OSD (On Screen display) will appear when Menu Button is selected. - OSD will disappear when Exit Button is selected. *On the main menu, you will see the current firmware & OSD version and I/O (Input / Output) connection information.
PureLink by Dtrovision - Detailed-Menu of Aspect will be selected when Aspect menu is highlighted by pressing Menu Button - Aspect Ratio will be changed to following three options: (Full<->panoramic<->Letter Box). - Go back to main Menu by pressing Exit Button - To change Image Layout, press the Menu Button when Layout menu is highlighted - To go to the Detailed-Menu, press Menu Button again.
PureLink by Dtrovision ※ Size/Position Offset Value ±1 ※ Size/Position Offset Max Value =±1000 ※ Image Size Max Value = 2048 x 2048 - Input source can be changed on the Input Menu (DVI or VGA source) - Source or EDID Data menu can be selected by using Up/Down Button - You can change the detail setting when one of the menu is highlighted - Go back to main menu by pressing Exit Button - DVI Selection: only DVI input will be activated - VGA Selection: Only VGA input will be activated - AUTO Scan Selection:
PureLink by Dtrovision - You can enter into EDID data Detailedmenu by pressing Menu Button when EDID Data is highlighted. - Check marked represents the current selection, and it can be changed to different data by pressing UP/Down Button - When you press Menu Button on the highlighted Data list it will store the data into its internal EEPROM ※ Ext EDID – Allowing user to read an EDID data and save its information to EEPROM (DVI Input).
PureLink by Dtrovision - You can use Up/Down Button to select the desired Timing option on the Output Format Detailed-Menu. - Go back to the main menu by pressing Exit Button - Use UP/Down Button to select the desired Output mode. ※ When it’s set to Dual In Single Out, the position of PIP (Picture in Picture) (VGA or DVI input) source vary depending on Input setting.
PureLink by Dtrovision 2. Operation Manual (LCD View) - Main Menu [Video Out Time] *1920x1200_60Hz* On the main Menu, use the Right/Left Button to display I/O timing information. [Video In Time] *1920x1200_60Hz* [ OSD Menu View] Press the Menu Button to display OSD on the monitor. Menu Sel: R/L Button - Menu List 1.Aspect Ratio 2.Video Layout Main Menu list will show when Right/Left Button is press 3.Reserved Use Right/Left Button to select the desired option and 4.
PureLink by Dtrovision - Layout Menu 1.Image Layout 2.Reserved - Select the Menu List 2. Video Layout when changing the Layout setting, and press the Menu Button to go to the detailed-menu. When Image Layout is highlighted re-enter Menu Button to go to the Image Layout Detailed-Menu Image Layout Detailed-Menu 1.H Image Size H Size: 0 2.V Image Size -Using Up/Down Button to select the list. -Press Left/Right Button change the value of each setting. V Size: 0 3.H Position H posi: 25 4.
PureLink by Dtrovision - Input Menu 1.Source Select 2.EDID Data Set -Menu List 4, Input Setup -> Press Menu Button -> Select the Source Menu and press the Menu Button again. [Input Port Sel] - DVI In - -Press Up/Down Button to select DVI or VGA Input Source [Input Port Sel] - Analog In - - Menu List 4.Input Setup -> Press Menu Button -> use the [Input Int EDID] Ext EDID(Output) [Input Int EDID] Down button to select EDID Data. - EDID Data List will show on the LCD display when press Menu Button.
PureLink by Dtrovision -Output Menu 1.Output Format 2.Output Mode -Menu List 5.Output -> Press Menu button to select The Output Format [Out Timing Sel] -Timing list will show when press Menu button. Auto Time Set [Out Timing Sel] - Select the desired timing list by pressing UP/Down 1920x1100 60Hz button. - Menu List 5.Output -> Press Menu button to select 1.Sing-I Sing-O 2.Dual-I Sing-O Output Mode - Select the desired Output Mode by pressing UP/Down button.
PureLink by Dtrovision 1-8 Connector Pin Assignment DC Input Part Number DC005 Pin No. Description 1 VCC( DC12V) 2 GND 3 GND Pin No. 1 2 3 Description TXD RXD GND Remark RS232C Part Number ECH350R-03 Remark Analog RGB Input Part Number DB15HD Pin No. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Description RED GREEN BLUE GND GND(DDC-RETURN) GND-RED GND-GREEN GND-BLUE N.C GND-SYNC GND DDC-DATA H-SYNC V-SYNC DDC-CLOCK Remark DVI-D Input & Output Part Number DVI-D 29pin Pin No.
PureLink by Dtrovision 1.9 Command Protocol RS-232C Control Code Configuration -AD-210 can be remotely controlled via RS-232 port. The control commend codes are as follows and the code is composed of ASCII 1. ASPECT RATE SET *CAP01! + ENTER *CAP02! + ENTER *CAP03! + ENTER Full Screen Panoramic Letter/Pillar Box 2. INPUT SOURSE SET *CIS00! + ENTER ANALOG INPUT (VGA) *CIS01! + ENTER DIGITAL INPUT (DVI) *CIS02! + ENTER AUTO SCAN 3. OUTPUT TIMINIG SET *COT00! + ENTER *COT01! + ENTER …….
PureLink by Dtrovision 1.10 Warranty 2 (Two) Year Warranty Dtrovision warrants this VGA/DVI to DVI Converter to be free from defects in workmanship and materials, under normal use and service, for a period of two (2) year from the date of purchase from Dtrovision or its authorized resellers.
PureLink by Dtrovision FCC/CE Statement This device complies with part 15 of FCC Rules and EN 55022/55024/61000-3 for CE certification. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must not accept any interference received, including interference that may cause undesired operation.