Data Sheet

CODE:
TYPE:
EN
Tel. +48-14-610-19-40, fax: +48-14- 610-19-50, www.pulsar.pl, e-mail:sales@pulsar.pl
DC/DC 2A module of converter switching
DC/DC20SE v.1.0/II
DC/DC 2A Step up/step down DC/DC converter with adjustable output voltage
L
W
H
DESCRIPTION
The DC/DC 2A (DC/DC20SE) voltage- step up / step down converter is used for maintaining a constant output voltage
in the range between 5÷15V DC, adjusted with the VADJ
VADJ
.
potentiometer, regardless of the input voltage fluctuations in the
range of 9,5V ÷ 16V. When the input voltage at the output is lower than needed, the converter increases it to the set value.
When the input voltage at the output is higher than needed, the converter lowers it to the needed value set by the
potentiometer The maximum load current is Imax=2A (Pmax = 24W). The module does not feature galvanic isolation
between input/output (IN-AUX) and operates on common "ground" (0V) potential (IN- and AUX- terminals are galvanically
connected = common terminal).
Pulsar
®
The module’s features:
· The DC/DC voltage- step up / step down converter with
adjustable output voltage
· Example of use: increasing voltage from 9,5V to 12V DC or
lowering voltage from 16V to 9V DC
· The input voltage range: 9,5÷16V DC
· The output voltage range: 5÷15V DC
· The maximum load current 2A (24W)
· The PSU technical output indicating converter failure
triggered by:
· Short-circuit of the output
· Output overload
· Protections:
· Short-circuit protection SCP
· Overload protection OLP
· High efficiency: 89%
· Optical LED indication
· Warranty – 2 years from the production date
· Mounting:
· Mounting strip with adhesive tape
· Mounting screws
The input voltage range (power supply)
9,5V÷16V DC
The output voltage range
5V÷15V, factory setting: 12V
P module power
24W max.
Energy efficiency
84%÷ 89%
Ripple voltage
60mV p-p max
Output current
2A max.
Current consumption by module systems
15 mA max.
Short-circuit protection SCP
electronic, automatic recovery
Overload protection OLP
110-150% of the module’s power, manual restart (the failure
requires disconnection of the DC output circuit)
Technical outputs
- PSU output indicating failure – overload or short-
circuit in the AUX output
- OC type, 50mA max. Failure status: hi-Z state (high
impedance), normal status: L level (0V)
Optical indication
- IN LED indicating DC power status
- AUX LED indicating DC supply status at the output
- PSU LED indicating failure - overload or short-
circuit in the AUX output
- red, normal status: is lit continuously
- green, normal status: is lit continuously
- red, normal status: does not lit, failure: is lit continuously
Operating conditions
II environmental class, -10°C ÷40°C, ensure air flow around
the unit for convection cooling
Dimensions
110 x 43 x 27 (L x W x H)
Net/gross weight
0,05/0,010kg
Mounting
mounting tape or mounting screw x 2
Declarations, warranty
CE, 2 years from the production date