Data Sheet

Table Of Contents
Relay modules
DC/AC power
AWZ 625 v.1.0/II
PU2/HV relay module
CODE:
NAME:
DESCRIPTION
The PU2/HV (AWZ 625) relay module is to be used in low-voltage installations. It is intended for controlling and
status indication in e.g. alarm or access control systems. It may be used to control devices of high power consumption via
OC outputs of alarm systems. Moreover, it ensures galvanic isolation of signals, power sources relating to the outputs of the
module.
Tel. +48-14-610-19-40, fax: +48-14- 610-19-50, www.pulsar.pl, e-mail:sales@pulsar.pl
Pulsar
®
EN
SPECIFICATIONS
Voltage of the relay’s coil 10÷16V DC/AC (-/+5%),
Current of the relay’s coil 33mA@12VDC
Coil resistance 360 OHM (-/+10%)
Coil power 400mW
Number of relays 2
Voltage of the relay’s contacts 30VDC / 250VAC max.
Current of the relay’s contacts 6A max.
Contacts of relay C/NC/NO
ON/OFF time 15ms/8ms (-/+5%)
Operating conditions 2nd environmental class, -10°C÷ 40°C
Enclosure open-frame design, IP00
Dimensions L=75, W=70, H=30 [mm, +/-2]
Net/gross weight 0,08 / 0,11 [kg]
Installation installation tape or installation bolt x2
Declarations, warranty CE, 2 year from the production date
Notes Leads on connections:
Ø 0,41÷1,63 (AWG 26-14) 0,2 ÷ 1,5mm
2
Ø 0,41÷2,59 (AWG 26-10) 0,5 ÷ 4mm
2
- relay contacts

Summary of content (1 pages)