Data Sheet

Table Of Contents
Relay module
Timing, AC control
Tel. +48-14-610-19-40, fax: +48-14- 610-19-50, www.pulsar.pl, e-mail:sales@pulsar.pl
AWZ 518 v.1.1/IV EN**
PC2 Timing relay module
CODE:
NAME:
DESCRIPTION
The PC2 timing relay module is intended for AC power status control in object alarm systems (monitoring
transmitters, alarm control panels, DC power supply units, etc.). The module informs about AC power loss with
a preset delay time and its returne. PC2 has two OC outputs (OC1, OC2) and an LED (L1) indicating the
device's status. Delay time indicating AC power loss is adjustable via two jumpers – Z1, Z2.
T
Pulsar
®
Supply voltage
10V ÷ 15V DC
Current consumption
5 mA
T delay adjustment range
4s/1min/16min/4h 15min (+/-10%)
AC1 input
0V ÷ 30V AC
Inactive input: 0V ÷ 1V AC
Active input: 5V ÷ 30V AC
GND = ‘VDC-‘ power terminal
Technical outputs:
- OC1 output
- OC2 output
OC type 50mA max.
· normal state: L (0V, GND),
· active state: hi-Z (high impedance)
· normal state: hi-Z (high impedance)
· active state: L (0V, GND)
LED indication
L1 green LED
Operating conditions
II environmental class -10°C ÷ 50°C
Dimensions
L=60, W=43, H=23 [mm, +/-2]
Installation:
A mounting panel with an adhesive tape, mounting
screws x2 (holes 3mm)
Connectors
Ф0,41÷1,63 (AWG 26-14)
Net/gross weight
0,03kg /0,05 kg
Declarations, warranty
CE, RoHS, 2 year from the production date
SPECIFICATIONS