Proxy Technologies, Inc. User manual For Proxy Reader Pro (Mullion) Document number: PRXY-1001UM Confidential V 1.
Proxy Reader User Manual Version HIstory: Date Version Description 11/10/2017 1.0 Initial Draft Andrew Tam 12/14/2017 1.1 Specs finalized, Line Drawings updated Andrew Tam 01/28/2018 1.2 Updated Table 4 Andrew Tam 7/31/2018 1.3 Updated WEEE, WiFi to IEEE 802.11, RF exp Andrew Tam 7/31/2018 1.4 Update rf power table FCC / IC / CE Andrew Tam 8/16/2018 1.5 Power limited Class 2 Andrew Tam 10/15/18 1.
Contents Proxy Reader User Manual 2 1.0 Introduction 4 2.0 Reader 2.1 Functionality 2.2 Proxy Reader Mullion Main Housing 2.3 Proxy Reader Mullion Wall Plate 4 4 4 5 3.0 Product details 6 4.0 Reader Specifications 4.1 Rated current at different operating voltages 4.1.1 Rated current for Model 8010 7 7 7 5.0 Installation details 5.1 Parts List 5.2 Recommended Infrastructure 5.3 Wiring Information 5.3.1 Cable Color codes for Pig Tail Reader 5.4 Mounting the Reader 5.4.
1.0 Introduction This document details the Physical Access Control Reader Proxy Reader Pro® and its basic operational and installation procedures. It covers the details of the Mullion form-factor reader. Model : Proxy Reader Pro : PRXY-MW-1.0 (white version) , PRXY-MK-1.0 (black version) The reader comes in one variant for interfacing with the control panel - Standard HF LF BLE IEEE 802.11b/g/n The reader comes in one variant in functionality - Standard HF LF BLE IEEE 802.11b/g/n 2.0 Reader 2.
2.3 Proxy Reader Pro Mullion Wall Plate User Manual Printed copies of this document are uncontrolled v1.
3.0 Product details Model Name : Proxy Reader Pro / PRXY-MW-1.0 / PRXY-MK-1.0 Device Type : RFID reader, 13.56MHz (HF) / 125 KHz (LF) / Mobile Credential: 2.4GHz (BLE) Physical Access control Reader (accessory equipment) Type of equipment : Sealed Reader Suitable for Indoor use and Outdoor use – PRXY-MW-1.0 and PRXY-MK-1.0 Interface Type : Pigtail Cable (11 Core + Drain) Electrical Rating : 6V - 16V DC , 0.5A, 8W (Max) Communication protocol : Wiegand, RS485 (2wire - Half Duplex), BLE, IEEE 802.
4.0 Reader Specifications Model Operating Voltage Current Rating Operating Temp. Proxy Reader Pro // PRXY-MW-1.0 // 6V - 16V DC 0.5A -35C to +66C , 85% RH PRXY-MK-1.0 HF LF BLE IEEE 802.11b/g/n There shall be no connections made to the RS-485 interface ( RS485+ and RS485-) for UL installations Note: - Standby Power is not provided by the Card Readers. The Standby Power Level is dependent on the external power source connected to the Card Reader.
5.0 Installation details Wiring methods shall be in accordance with the National Electrical Code (ANSI/NFPA70), local codes, and the authorities having jurisdiction. 5.1 Parts List ○ ○ ○ ○ Proxy Reader - 1 Security Screw – #6 - 32 x 3/8” -- 1 Nos Mounting Screws -- #6-32 x 1” -- 2 Nos Nylon anchor plugs -- #6 Size x 1” -- 2 Nos 5.
5.3 Wiring Information 5.3.1 Cable Color codes for Pig Tail Reader Red +VDC 12V (nominal) Black & White Ground Green Wiegand Data 0 White Wiegand Data 1 Orange Green LED Yellow Buzzer Blue Hold Brown Red LED Grey RS485 - Pink RS485 + Violet Tamper Output Black / Drain Shield Ground N, ** For Wiring diagrams and termination points please see your control panel user manual. Installations will differ between access control panel manufacturers.
5.4 Mounting the Reader 5.4.1 Location of mounting holes on wall 5.4.2 Reader Installation Steps ● ● ● ● ● ● Make two holes on the wall as per the image above corresponding to the type of reader. Insert the nylon screw plugs into the wall. Connect the wires as per the Table in Section 5.3.
5.
6.0 Certifications 6.1 FCC Tune up power table BLE / WLAN - Each product is programmed with the pre-defined RF parameters Each product RF power level is measured to ensure the power level not exceeding the target power level, in a fully calibrated setup. The user has no possibility to change these settings later on Please find below the Maximum Transmit Power for production units: Average Power (dBm) Band / Mode LE GFSK Bluetooth Band / Channel / Frequency (MHz) 2.4GHz WLAN 7 IEEE 802.
—Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. —Consult the dealer or an experienced radio/TV technician for help. RF Exposure Information This device has been tested and meets applicable limits for Radio Frequency (RF) exposure. This equipment should be installed and operated with minimum distance 20 cm between the radiator & your body. Information to user This device complies with part 15 of the FCC Rules.
This equipment should be installed and operated with minimum distance 20 cm between the radiator & your body. Informations d’exposition RF Cet appareil a été testé et répond aux limites applicables en matière d’exposition aux radiofréquences (RF). Cet équipement doit être installé et utilisé avec une distance minimale de 20 cm entre le radiateur et votre corps. 6.
Waste Electrical and Electronic Equipment (WEEE) This symbol means that according to local laws and regulations your product and/or its battery shall be disposed of separately from household waste. When this product reaches its end of life, take it to a collection point designated by local authorities. Proper recycling of your product will protect human health and the environment.