Model No. PFSB63131 Serial No. The serial number is on a sign behind the access panel. Write the serial number in the space above. USER’S MANUAL Access Panel QUESTIONS? If you have questions, or if there are missing parts, we will guarantee complete satisfaction through direct assistance from our factory. TO AVOID DELAYS, PLEASE CALL DIRECT TO OUR TOLLFREE CUSTOMER HOT LINE. The technicians on our customer hot line will provide immediate assistance, free of charge. CUSTOMER HOT LINE: 1-888-884-6555 Mon.
Table of Contents Posting the Warning Sign . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Important Safety Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Before You Begin . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Important Safety Instructions WARNING: To reduce the risk of drowning, electric shock, or serious injury, read the following important precautions before using the hydrotherapy spa. READ AND FOLLOW ALL INSTRUCTIONS 1. It is the responsibility of the owner to ensure that all users of the hydrotherapy spa are adequately informed of all precautions. 10. Never insert any object into any opening. 11. Do not use breakable containers in or near the hydrotherapy spa. 2.
physician before using the hydrotherapy spa. Pregnant women should not use the spa if the water temperature is above 100°F; the unborn child could be seriously harmed. This is especially important during the first 90 days of the pregnancy. 20. DANGER—Risk of electric shock. Keep all electrical appliances such as radios, telephones, televisions, and lights at least five feet away from the water. 21. A wire connector is provided on the electronics pack of the hydrotherapy spa to connect a minimum No.
35. WARNING: The spa jets produce a stream of water with relatively high pressure. Prolonged exposure of a localized area of the body may cause bruises to the skin. 36. The included warning sign must be posted where all users of the hydrotherapy spa can see and read it. (See POSTING THE WARNING SIGN on page 2.) 37. WARNING DECAL PLACEMENT: Locate the decals shown below and familiarize yourself with the information on the decals. WARNING: Read all instructions before using the hydrotherapy spa.
Before You Begin Congratulations for selecting the new PROFORM® STORM hydrotherapy spa. The innovative STORM spa allows you to enjoy all the benefits of hydrotherapy in the comfort and privacy of your home. For your benefit, read this manual carefully before using the hydrotherapy spa. If you have questions after reading the manual, please call our Customer Service Department toll-free at 1-888-884-6555, Monday through Friday, 8 a.m. until 5 p.m. Central Time (excluding holidays).
Choosing a Location for the Hydrotherapy Spa There are many factors to consider when choosing a location to set up the hydrotherapy spa. These factors vary depending on whether you plan to use the spa inside or outside. We have listed several factors you may wish to consider as you decide where to set up the spa. If you set up the hydrotherapy spa inside: If you set up the hydrotherapy spa outside: 1. The spa will increase the level of humidity in your home.
Assembly Before beginning assembly, carefully read the following information and instructions: ASSEMBLY REQUIRES THE FOLLOWING TOOLS (not included): • Place all parts in a cleared area and remove the packing materials from the spa shell. Do not dispose of the packing materials until assembly is completed and the spa is operating. • One phillips screwdriver A wire connector is provided on the electronics pack of the spa to connect a minimum No. 6 AWG (13.
3. Insert the Pillow (38) into the lounge seat receptacle. Note: Rotate the Pillow 180º to change between the high and low positions. 3 38 4. The spa should be located near a power source capable of supplying 240 volts AC power. It must be wired directly into a grounded circuit with a 45 amp circuit breaker and a Ground Fault Circuit Interrupter (GFCI) capable of carrying 45 amps. No other appliance should be on the same circuit. This procedure must be performed by a qualified, licensed electrician.
Using the Hydrotherapy Spa 4. Turn the power on. The spa will begin an automatic priming sequence. The hydrotherapy spa is designed to seat seven adults. The spa holds approximately 375 gallons of water and offers a heating system (80°F to 104°F), a filtration system, and adjustable hydrotherapy jets. Follow the guidelines below to use and maintain the spa for your long-term enjoyment. A countdown from “005” to “000” will appear in the display of the console.
Once you have tested the GFCI, verify that water is flowing from the jets. Set the air controls to the lowest setting (see USING THE CONTROLS on page 13). Cover the hydrotherapy spa with the spa cover. The spa cover must be tight (see SECURING THE SPA COVER ON THE SPA on this page). The water will heat at about 6°F per hour with the cover on. If you are using the spa indoors, and the room temperature is maintained at 70°F, it will take approximately 6 to 8 hours for the water to reach the set temperature.
Jet Layout Diagram G M K D G G J I I I D G D B H B A F C E I B H L D B H I H I M A. The underwater light can be used for night operation. The spa includes both red and blue covers for the light. G. The four neck jets can be adjusted to spray soothing water on your neck. H. The eleven rotary jets provide a spinning massage. B. The ten air injectors create air bubbles that enhance the hydrotherapy experience. I. The six dual rotary jets provide a pulsating massage action.
Using the Controls Waterfall Valve Air Controls 1, 2, and 3 Waterfall Blower Button Mode Button Waterfall Waterfall Valve Display Pump Button 1 Pump Button 2 Light Button Temperature Buttons current only when pump 1 has been operating for two minutes. “Std” displays momentarily when the Standard mode is selected. 1 2 3 • Economy mode heats the spa to the set temperature only during the filter cycles.
Your spa features an LED light with ten different programmed lighting effects: 1. White 2. Color Spectrum (each color is displayed for approximately one minute) 3. Yellow 4. Blue 5. Orange 6. Green 7. Hot Pink 8. Cyan 9. Blue/Green Mix 10. Party ModeTM (colors cycle rapidly through the color spectrum) The Temperature Buttons control the temperature setting of the water. The temperature setting can be from 80°F to 104°F. The startup temperature is set at 100°F.
Maintenance The hydrotherapy spa is designed to provide years of enjoyment. Please follow the guidelines below to properly maintain your spa. MAINTAINING THE SPA COVER The spa cover should be cleaned monthly. To clean the spa cover, use water and a non-abrasive cleaner on the entire cover. Rinse the cover with a garden hose to remove any cleaner residue. Dry the cover entirely. Use a non-silicone-based vinyl conditioner on the cover after you clean it. This will help protect the cover from sun damage.
To maintain the proper pH level, test the pH of the water regularly. To test the water, purchase a pH test kit at a pool and spa supply store. The pH reading should be between 7.2 and 7.8. If the level is too low, add a pH increaser (usually soda ash). If the level is too high, add a pH reducer (usually sodium bisulfate). Test the water again after five minutes. See the instructions with your pH test kit for additional information about testing and adjusting the pH.
ATTACHING AND REMOVING THE ACCESS PANELS To drain the hydrotherapy spa, follow the steps below: 1. Using the console, adjust the temperature to the lowest setting. 2. Shut off the power to the spa, at the circuit breaker or GFCI. 3. Remove the access panels from the spa (see ATTACHING AND REMOVING THE ACCESS PANELS on this page). 4. Pull the hose out and hold it above the waterline. Remove the cap, open the valve knob, and attach a garden hose to the drain hose. Lower the hose and drain the spa.
DRAINING THE PUMPS REPLACING THE LED LIGHT After the hydrotherapy spa is drained, the jet pumps should also be drained if the spa will be stored for more than thirty days or if it may be exposed to freezing temperatures. Remove the access panels (see ATTACHING AND REMOVING THE ACCESS PANELS on page 17). Make sure the spa power is turned off. Next, locate the light housing. Turn the light housing counterclockwise and remove it from the spa shell. Turn off the power to the spa.
Troubleshooting Most problems can be solved by following the simple steps below. Find the symptom that applies, and follow the steps listed. If further assistance is needed, call our Customer Service Department toll-free at 1-888-884-6555, Monday through Friday, 8 a.m. until 5 p.m. Central Time. 1. SYMPTOM: THE SPA WILL NOT OPERATE 6. SYMPTOM: THE WATER DOES NOT HEAT a. Check to see if the GFCI breaker is tripped or was not turned on. Reset the GFCI breaker. a.
9. SYMPTOM: THE WATER LEVEL DROPS 11. SYMPTOM: THE CONSOLE DISPLAYS “--,” “OHH,” “ICE,” “SnA,” “SnB,” “SnS,” “HFL,” “LF,” “dr,” “OHS,” or “drY” a. A clamp or seal inside the pump compartment may be loose. Check inside the pump compartment for excess water and watch the pump unit while it is operating to see if water drips from any of the plumbing. If you can identify the location of the leak inside of the spa jet unit, tighten the clamp or replace the damaged seal. a.
NOTES 21
Part List—Model No. PFSB63131 Key No. Qty. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 1 2 1 8 1 2 11 1 6 1 1 4 4 1 5 6 4 3 1 1 1 1 8 1 2 4 8 8 Description R0404A Key No. Qty.
Model No.