SNS™ Digital Clock/Timer User Guide
Page ii SNS™ Digital Clock/Timer User Guide Notices © Copyright 2008, Primex Wireless; all rights reserved. Trademarks SNS and AMP are trademarks of Primex Wireless, Inc. Contact Primex Wireless Web: http://www.primexwireless.com/ Email: support@primexwireless.
SNS™ Digital Clock/Timer User Guide Page iii Contents Introduction .............................................................................................................................................1 Precautions and regulatory compliance statements ...........................................................................2 SNS digital clock/timer features and models .......................................................................................4 SNS digital clock features ..............
Introduction Primex Wireless’s Synchronous Network System (SNS™) digital clock/timers are equipped with both a wireless 802.11 b/g interface and a wired Ethernet port interface. Viewable up to 150 feet away, these bright LED-digit clock/timers are perfect for hallways and large rooms. They’re also easy to install – simply connect the power source and the clock/timer is instantly synchronized to the Primex Wireless system.
Page 2 SNS™ Digital Clock/Timer User Guide Precautions and regulatory compliance statements This section contains mandatory precautions and regulatory compliance statements. Safety precautions The SNS digital clock/timer must be connected to a properly grounded outlet and it is designed for indoor use only. It is not weather protected. Operating the SNS digital clock/timer outdoors, or in wet areas is an electrical hazard and may damage the SNS digital clock/timer while nullifying the warranty.
SNS™ Digital Clock/Timer User Guide Page 3 FCC radiation exposure limits To comply with FCC RF exposure requirements in section 1.1307, a minimum separation distance of 7.87” (20 cm) is required between the antenna and all persons.
Page 4 SNS™ Digital Clock/Timer User Guide SNS digital clock/timer features and models This section provides information about SNS digital clock/timer features and models.
SNS™ Digital Clock/Timer User Guide Page 5 SNS digital clock features All SNS clock/timers include either an 18” pigtail or a 9ft cord with a three-prong grounding plug.
Page 6 SNS™ Digital Clock/Timer User Guide SNS Elapsed Timer digital timer features The Primex Wireless Elapsed Timer is a multi-function product. It has the capability of functioning as a normal clock and as an elapsed timer with both count up and count down options. It functions in much the same way as a standard digital clock. The elapsed timer is two timers in one: • Up counter The up counter can count up from any preset time to 99:59:59 (99 hours, 59 minutes, 59 seconds).
SNS™ Digital Clock/Timer User Guide Page 7 SNS Code Blue digital timer features The Primex Wireless Code Blue timer is a multi-function product. It has the capability of functioning as a normal clock, code blue timer, and an elapsed timer with both count up and count down options. It functions in much the same way as a standard digital clock. The Code Blue timer is three timers in one: • Up counter The up counter can count up from any preset time to 99:59:59 (99 hours, 59 minutes, 59 seconds).
Page 8 SNS™ Digital Clock/Timer User Guide Note: This feature requires a minimum of 1 hour of charging time. • Code Blue trigger voltage: 5-120V (AC or DC). Note: When using DC, be sure to use the correct polarity (red is positive).
SNS™ Digital Clock/Timer User Guide Page 9 SNS digital clock/timer models This section provides tables detailing the available SNS digital clock/timer models and their dimensions: • 2.5" x 4-digit red wall mount • 2.5" x 4-digit green wall mount • 2.5" x 6-digit red wall mount • 2.5" x 6-digit red flush mount • 4" x 4-digit red wall mount • 4" x 6-digit red wall mount • SNS digital clock/timer dimensions 2.
Page 10 SNS™ Digital Clock/Timer User Guide 2.5" x 6-digit red wall mount US model # Cable type Mounting option Current draw @ 120V~ Weight (lbs) Type SNS7B202 9-foot cord with plug 4° tilt bracket 260 mA 2.96 LED clock SNS7Y202-1 18-inch pigtail 4° tilt bracket 260 mA 2.62 LED clock SNS7B419 9-foot cord with plug 18° tilt bracket 260 mA 3.16 LED clock SNS7Y419-1 18-inch pigtail 18° tilt bracket 260 mA 2.
SNS™ Digital Clock/Timer User Guide Page 11 4" x 4-digit red wall mount US model # Cable type Mounting option Current draw @ 120V~ Weight (lbs) Type SNS7B201 9-foot cord with plug 4° tilt bracket 230 mA 6.02 LED clock SNS7Y201-1 18-inch pigtail 4° tilt bracket 230 mA 5.7 LED clock 4" x 6-digit red wall mount US model # Cable type Mounting option Current draw @ 120V~ Weight (lbs) Type SNS7B203 9-foot cord with plug 4° tilt bracket 260 mA 7.
Page 12 SNS™ Digital Clock/Timer User Guide SNS digital clock/timer dimensions Note: *D dimension is the mounting screw spacing on the clock/timer. Clock/timer type Dimensions A B C D E F G H 2.5” 4-digit LED clock/timer 5.0” 10.75” 2.5” 6.0” 0.38” – 0.63” 2.125” 8.0” (4°), 9.5” (18°) 2.5” 2.5” 6-digit LED clock/timer 5.0” 13.75” 2.5” 6.0” 0.38” – 0.63” 2.125” 8.0” (4°), 9.5” (18°) 2.5” 4” 4-digit LED clock/timer 8.0” 18.0” 3.0” 14” 0.4 – 0.9” N/A 12.0” 4.
SNS™ Digital Clock/Timer User Guide Page 13 Using SNS elapsed timers and Code Blue timers This section provides instructions for using SNS elapsed timers and Code Blue timers.
Page 14 SNS™ Digital Clock/Timer User Guide Elapsed timer/Code Blue timer states An elapsed timer/code blue timer can be in one of three states: • Normal state • Set state • Power failure state (Code Blue timers only) Normal state controls the operation of the timer and is the text labeled on the top of the buttons in the illustration shown here. Set state controls setting up the timer and is the text labeled on the bottom of the buttons in the illustration shown here.
SNS™ Digital Clock/Timer User Guide Page 15 Normal state In normal state, the clock/timer can be in one of four modes: • Clock mode • Count up mode • Count down mode • Code blue mode In Normal state, the text labeled on the top of the buttons is applicable (DISPLAY, STOP/START, RESET). The table below summarizes the results when each button is pushed while in a specified mode.
Page 16 SNS™ Digital Clock/Timer User Guide Set state The set state is used for setting the count up default start time and the count down default start time. It is entered by holding the Reset button while in count up or count down modes. In this state, the text labeled on the bottom of the buttons is applicable (SET/CHANGE, INCREMENT, EXIT).
SNS™ Digital Clock/Timer User Guide Page 17 Start/pause/resume/set count down This section provides step-by-step instructions to start/pause/resume/set count down timer functions. The section presents the following topics: • Start count down • Pause count down • Resume count down • Set count down start point Start count down Follow these steps to start count down: 1.
Page 18 SNS™ Digital Clock/Timer User Guide Resume count down Follow these steps to resume count down: 1. Press the DISPLAY button repeatedly until the clock/timer display indicates count down mode (the decimal following the seconds character is lit). 2. If the clock/timer display shows a stopped count, press the STOP/START button. Set count down start point Follow these steps to set the count down start point: 1.
SNS™ Digital Clock/Timer User Guide Page 19 Start/pause/resume/set count up This section provides step-by-step instructions to start/pause/resume/set count up timer functions. The section presents the following topics: • Start count up • Pause count up • Resume count up • Set count up start point Start count up Follow these steps to start count up: 1. Press the DISPLAY button repeatedly until the clock/timer display indicates count up mode (the decimal following the hours character is lit). 2.
Page 20 SNS™ Digital Clock/Timer User Guide Resume count up Follow these steps to resume count up: 1. Press the DISPLAY button repeatedly until the clock/timer display indicates count up mode (the decimal following the hours character is lit). 2. If the clock/timer display shows a stopped count, press the STOP/START button. Set count up start point Follow these steps to set the count up start point: 1.
SNS™ Digital Clock/Timer User Guide Page 21 Start/end/display a code blue event This section provides step-by-step instructions to start/end/display code blue timer functions. The section presents the following topics: • Start a code blue event • End a code blue event • Display the results of the last code blue event Start a code blue event Press the button/control that’s been installed in the patient treatment area to start a code blue event.
Page 22 SNS™ Digital Clock/Timer User Guide SNS digital clock/timer installation These clock/timers require either a standard CAT-5 network cable with an RJ-45 connector or access to an 802.11 b/g wireless local area network (WLAN). Primex Wireless SNS digital clock/timers and timers are shipped from the factory with either a three-prong grounded plug or pigtail for permanent installation. Pigtail installations require a 120V~ power line in a 4” x 4” junction box installed by a licensed electrician.
SNS™ Digital Clock/Timer User Guide Page 23 Tilt-bracket clock/timer installation Hard-wired installations require a 120V~ power line in a 4” x 4” junction box installed by a licensed electrician. The tilt bracket has a center pass-through hole for the 120V~ pigtail. Note: The RJ-45 jack for the network cable is on the bottom of the clock/timer. Most building codes prohibit running network cables through the same junction box as line voltage.
Page 24 SNS™ Digital Clock/Timer User Guide Direct wall-mount clock/timer installation Mount the clock/timer directly to the wall with two #10 screws and anchors (provided). See dimension D in the SNS digital clock/timer dimensions table for the spacing of the screws. Direct wall mounting Hook on screw head features 1/8" recommended spacing Note: Most building codes prohibit the use of hard-wired power connections for devices that can be removed without tools.
SNS™ Digital Clock/Timer User Guide Page 25 Flush-mount clock/timer installation Follow these steps to install a flush-mount clock/timer: Step 3 Step 1 Step 3 Step 4 Step 7 Step 5 Faceplate Step 6 1. Prepare an opening using the following dimensions: 5.5”H x 14.25”W. 2. Inside the opening install an expandable fan brace bar between the wall studs.
Page 26 SNS™ Digital Clock/Timer User Guide 4. Connect the wires to the electrical box with the appropriate fittings. Then use a “U” clamp to attach the electrical box to the brace bar. Note: Leave enough extra wire length (armored cable) so that the electrical box can be wired in the 5.5”H x 14.25”W opening. 5. Connect the appropriate fitting to the clock/timer cord and then attach the fitting to the electrical box.
SNS™ Digital Clock/Timer User Guide Page 27 Timer control switch installation SNS elapsed timers and Code Blue timers include a control switch that must be mounted in a singlegang junction box (not included). These boxes are typically 2¼” x 2¾” x 4” (5.72cm x 6.99cm x 10.16cm). The switch’s wall plate cover is stainless steel. The switch’s buttons and wall plate cover may be cleaned with water and/or most common disinfectant.
Primex Wireless – United States 965 Wells Street Lake Geneva , Wisconsin 53147 Phone: (800) 537-0464 Fax: (262) 248-0061 Email: support@primexwireless.com Web: http://www.primexwireless.