IMS-310R
iPRECIO® IMS-310R Quick guide ver.1.0.0.E Read me Thank you for choosing iPRECIO®, programmable infusion pump for Lab animal for your research/experiments. This quick guide show you how to use iPRECIO® pump and operate iPRECIO® management software. The iPRECIO® is for use in Laboratory Animal Research ONLY. Not for human use. Please obey the Guide for the Care and use of laboratory animal by your organization and or institute when use iPRECIO®.
iPRECIO® IMS-310R Quick guide ver.1.0.0 E INFORMATION TO THE DIGITAL DEVICE USER REQUIREMENT by FCC (For Model UCD-X10R only) This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
iPRECIO® IMS-310R Quick guide ver.1.0.0.E Contents READ ME .................................................................................................................................. 2 CONTENTS ............................................................................................................................... 4 ABOUT IPRECIO® ...................................................................................................................
iPRECIO® IMS-310R Quick guide ver.1.0.0 E About iPRECIO® A subsequent of the first radio programmable infusion pump iPRECIO® SMP-310R model is the world first programmable pump which is complete implantable into a laboratory mouse. Utilize high precision mechanical pump technology that was unique developed and controlled by built in microprocessor.
iPRECIO® IMS-310R Quick guide ver.1.0.0.E iPRECIO® System construction ⑤ UCD-X10R ⑥ ⑦ Number ① ② ③ ④ ⑤ ⑥ ⑦ ⑧ ⑧ name Refill septum Outlet tube Reservoir Micro cam Pump ID print mark LAN cable connect port USB power adopter connect port Reset switch 6 www.iprecio.
iPRECIO® IMS-310R Quick guide ver.1.0.0 E Product Warranty PRIMETECH CORPORATION (hereinafter PRIMETECH) guarantee the product and it’s material are free from defect within the below period which was distributed through the official sales channel. PRIMETECH do not responsible with any problem that caused by using with other company product. Also the product performance is not guaranteed when a customer uses it beyond the original specification.
iPRECIO® IMS-310R Quick guide ver.1.0.0.E Battery life iPRECIO® SMP-310R can continuous operate time below table during product warranty period (After 16 months from manufacturing date) Flow rate (μl/hr) Battery life (hr) 0.1 408 0.5 384 1.0 360 5.0 216 10.0 144 Please note that below condition makes shorter battery life. : In case of kept certain period of time without use after power on.
iPRECIO® IMS-310R Quick guide ver.1.0.
iPRECIO® IMS-310R Quick guide ver.1.0.0.E 4. When install complete windows appears, click “Close”. 5. Check start menu that the following software installed. iPRECIO® Management Software IMS-X10R Utility Base Station Manager Utility Pump Database Manager 6. Three of those software has been installed, then the management software install is successful. 10 www.iprecio.
iPRECIO® IMS-310R Quick guide ver.1.0.0 E Cable connection of data communication unit UCD-X10R 1. Plug in the AC Adapter to data communication unit and connect with the PC which the management software installed by cross-over type LAN cable. Connect to LAN port of UCD-X10R Plug in the USB Adapter to a PC USB port (USB 2.0 or later) Connect to LAN port of Control PC Plug in the power plug to a UCD-X10R power in port. *LAN cable Ferrite core attached end shall be connected to UCD-X10R.
iPRECIO® IMS-310R Quick guide ver.1.0.0.E Then press OK to finalize. The Data communication unit factory default IP address configuration is 192.168.1.10. If IP address doesn’t work by usage environment with default configuration, please change IP address in accordance with “Appendix A: How to change IP address of the Data communication unit” 5. With that the Data communication unit and control PC is connected by Internet Protocol. Subsequently network connection should be made in the management software.
iPRECIO® IMS-310R Quick guide ver.1.0.0 E Preparation before software use For the first time execute management software For the first time run the management software, the user registration window will open automatically. To register user information, user management and access control function will be available. The language default setting is in English and after user registration the language selectable function will be active to change. User Registration 1.
iPRECIO® IMS-310R Quick guide ver.1.0.0.E Access Control of software To utilize Access Control function, administrator can confine and or control of user who can reach the management software. To permit to access the software, check the “Enable Access Control” in the user registration window. Once use control function is active, every time Login ID and Password is required whenever the software executed. Please note Login ID and Password. When forgot password, then software access will be denied.
iPRECIO® IMS-310R Quick guide ver.1.0.0 E Change Language 1. Click Language menu 2. Select language from pull down menu, then click Change. 3. Now the language has been changed. Network Setting 1. Click network setting menu in tab. 2. Input default IP address(192.168.1.10) in the Host IP address column for the data com unit. 3. Click “connect” 4. After confirm “Status: connected”, then close the window. 5. If the status column shows “disconnected”, check the IP address setting.
iPRECIO® IMS-310R Quick guide ver.1.0.0.E 2. Administration window comes up. 3. Add new administration profile, click “Add” button. 4. Group profile creating window will be opened. 5. Input and or select basic information. When chose the injected amount unit as μg/kg/hr(Dose) or mg/kg/hr(Dose), amount set by dose. It is therefore the animal weight range and concentration input are mandatory. 16 www.iprecio.
iPRECIO® IMS-310R Quick guide ver.1.0.0 E 6. Input dose amount and duration from Step1 to create the infusion schedule. Input the value to the each boxes and press Enter to finalize dose. The starting time and finish time will be shown in elapsed time that accumulate the injection period. The battery life shown in the bottom of window indicate the expected battery life which calculated as a new battery. It may help to create an administration schedule. Weight range should be input by maximum to minimum.
iPRECIO® IMS-310R Quick guide ver.1.0.0.E 9. When to change the existing Infusion Profile, select intended Infusion Profile and click “Edit”button. If want to eliminate the existing Infusion Profile on the list, select the intended Infusion profile to delete and click the “Delete” button. 10. Close the Infusion profile window by clicking “Close” button. 18 www.iprecio.
iPRECIO® IMS-310R Quick guide ver.1.0.0 E Customize information Pull down menu registration and elimination are possible for Study Setting. And KVO setting of flow rate and duration also set in advance. 1. Open customize window from “Customize(Z)” menu in the tool bar. 2. Input a desire information in the Animal Species, Animal Strain and Administration Route, then click Add button in the below of each boxes. 3.
iPRECIO® IMS-310R Quick guide ver.1.0.0.E Start Study Start New Study iPRECIO® Management software has a function to abort the study during the KVO and Administration with pumps which implanted in under study animals. For example, to be able to except individual animal from study that is slow-healing than others during KVO. Also even during Administration to be able to deselect individual animal that is difficult to continue Administration by some trouble.
iPRECIO® IMS-310R Quick guide ver.1.0.0 E 1. Click New from file menu bar. 2. Appear Study Header window. (*) marked items are mandatory. 3. Click Next after fill the information input boxes. 4. Pumps and Animals setting window comes up. Input intend animal number in the Number of Animals and click Set button. Default Number of Animal is 20. The information input column will be active in answer to input animal number. 5.
iPRECIO® IMS-310R Quick guide ver.1.0.0.E Catheter connection, plomb admin liquid and activation. Activate the pump by switch on to communication enable. If required connect additional catheter as necessary. To fill administration liquid till the end of catheter before power on, because once a pump switched on, the internal cam will start moving to the initial position to block the inner tube. 1. Open pump pre-sterilization pack in clean environment. 2.
iPRECIO® IMS-310R Quick guide ver.1.0.0 E 4. Slide the south pole of a magnet (100mT or stronger) on the surface of the protracted area of a pump to power on the pump. Under red marked area, magnet SW was built in. Pump detection 1. Place pumps by recommended position with a data com unit UCD-X10R. 2. Click Detect button. During Communication progress bar is shown, the powered on and communication enable pump will be detected.
iPRECIO® IMS-310R Quick guide ver.1.0.0.E environment. Verify PC and UCD-X10R connect properly. For detail, please refer “TCP/IP connection between data com unit and control PC” and “Network Setting”. Verify pump activation. For detail, please refer “Catheter connection, plomb admin liquid and activation”. 3. After all pumps detected, then click Next button.
iPRECIO® IMS-310R Quick guide ver.1.0.0 E Even if there is no need to change dead volume setting, it need to open every animal dead volume setting and determine the dead volume choice. If this determine was lost, the dead volume and flash rate will not apply to the administration start schedule. 4. Check KVO flow rate and KVO duration and if it’s ok then click to KVO start. The pump status will be KVO after start KVO. Pump status color will change in accordance with communication stats, red Yellow Green.
iPRECIO® IMS-310R Quick guide ver.1.0.0.E Infusion Protocol setting 1. Group information window appears. 2. Chose infusion group name (Profile) from Group ID pull down menu and set Administration Start Time, then click Set button. 3. When click Stagger, the administration will be staggered from set time in that value. 4. If the proper infusion group name does not found, then create new one. Please refer “Create Infusion Profile”. 5. After all animal are assigned to profile group, click Next>> button.
iPRECIO® IMS-310R Quick guide ver.1.0.0 E Monitor the running pump status 1. Open Monitor window by clicking Monitor (M) from menu bar. 2. Upper part of window shows Study Name, Group and Animal. Select Group ID from pull down menu in Group column and Animal ID from Animal column. 3. There is Refill Log table in the Right side. At first input the medical solution refill time and volume, then click Enter button. For detail, please refer “Replace and/or refill drag solution”. (Nest chapter) 4.
iPRECIO® IMS-310R Quick guide ver.1.0.0.E Replace and/or Refill the medical solution 1. 2. 3. 4. Open Monitor (M) window. Verify the estimated remain volume in the bottom area. Make pump implanted animal immobilization by weak anesthesia or retention. When replace the solution, aspirate remain fluid in reservoir by 27G syringe needle through the skin to port. Subsequently fill the replacing solution into syringe and refill it to reservoir.
iPRECIO® IMS-310R Quick guide ver.1.0.0 E End of Study After all infusion protocol finished, click “Study End” makes automatically record study date and finish study. If study should be abort during infusion schedule, click “AbortAll” then click “Study End” Save Study file 1. Click Save Study from the File (F) in menu bar. The data file stored in C:\Users\XXX\AppData\Local\iPRECIO\study 2. The save data can be loaded from “Open” in the File (F) in the menu bar. Export Study file 1.
iPRECIO® IMS-310R Quick guide ver.1.0.0.E Product Specification Micro infusion pump for small laboratory animal iPRECIO®(Model:SMP-310R) Administration method Rotary finger type (Patented: Peristaltic mechanism) Reservoir 130μL Built-in reservoir: (Material) Medical grade SEBS The Maximum capacity is 130 μ L, but out of accuracy guarantee range. To keep accuracy, only within 100μL is guaranteed. Tube Inner Tube: (Material) Medical grade SEBS Outer Tube: (Material) Medical grade SEBS (3Fr) (Size) ID=0.
iPRECIO® IMS-310R Quick guide ver.1.0.0 E STD accessory Management software Supported OS 31 www.iprecio.