WorkZone PreView™ WZPV4010 │ WZPV4015 │ WZPV4020 Operating Manual / Installation Guide www.PreViewRadar.
FCC STATEMENT This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Warning: Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
Contents Product Description ...................................................... 1 Sensor/Antenna Description ..................................... 2 Operator Display Description.................................... 2 Installation Instructions ................................................ 6 PreView™ DAILY MAINTENANCE ............................ 10 Troubleshooting ......................................................... 12 Specifications .............................................................
MANUFACTURER LIMITED WARRANTY AND LIMITATION OF LIABILITY Manufacturer warrants that on the Date of Purchase this Product will conform to Manufacturer's published specifications for the product, which are available from Manufacturer on request, and Manufacturer warrants that the product is free from defects in materials and workmanship. This Limited Warranty extends for twenty-four (24) months from the date of manufacture.
Sensor/Antenna Description Specifications SENSOR SPECIFICATIONS (Typical) Transmitter: Pulsed RF transmitter at 5.8GHz operating under FCC Part 15.249 Electronics: Solid state Connector: Conxall 72x1-8PG series Sealing: Encapsulated to protect from dust and moisture to IP67. Housing Material: Polycarbonate radome Dimensions: 4.38”H x 9.24"W x 1.75"D (11.1cm x 23.5cm x 4.4cm) Weight: 1.5 lb. (0.
Range Indications 5 Zones Buzzer Troubleshooting Display Status LED is not illuminated. • Verify that DC power (9-33V) is applied to the sensor. • Verify that the cable between the sensor and display is connected. Display Status LED is RED. • Check connection between display and sensor. Volume Control Switch Status LED Item Status LED Range Indications Buzzer Volume Control Switch Description Illuminates green continuously after power is applied to the system.
3. Set the park brakes, start the vehicle, depress and hold the vehicle brake and place the vehicle in reverse. 4. Verify the green “POWER” light is illuminated on the in-cab display. 5. The area to the rear of the vehicle should be clear of obstacles for a distance of 8 meters. If the display shows any indicator other than the green light then there are objects to the rear of the vehicle that will interfere with the test. Move the vehicle to a clear area and proceed. 6.
Minimal reflection Object surface at A 45 degree angle to the PreView™ sensor PreView™ sensor PreView™ DAILY MAINTENANCE Transmitted signal Detach this page and place with daily operator maintenance procedures. Safety Message to Operators of Vehicles with PreView tm Systems 1. Object in the PreView™ system detection zone Reflected signal doesn’t return to the PreView™ sensor 2. Full reflection PreView™ sensor Transmitted signal 3. 4.
Initial System Power Up and Test Once the sensor and display are installed, wired, and connected, power should be applied to test correct system operation. Upon power up, the display will go through its self-test by illuminating all LED’s and sounding the buzzer. When the system is operating correctly in an open field with no obstructions, the status LED indicating green will be the only light illuminated.
Sensor/Antenna Mounting 1. Select the appropriate sensor mounting location. 2. The standard mounting configuration is with the sensor’s stylized “V” logo pointing down. 3. Using the sensor’s mounting holes as a template, scribe position marks through the holes. Drill 1/4” (6mm) holes centered at the marks. 4. A 1” diameter clearance hole is required for the sensor connector and mating cable connector. 5.