PreView® Wireless Display WD7102 Operating Manual Proudly developed by 10335 W. Emerald St. Boise, Idaho 83704 Phone 1.844.787.2327 www.PreViewRadar.com (866) 977-7326 www.PreViewRadar.
Warranty Information: MANUFACTURER STANDARD LIMITED WARRANTY AND LIMITATION OF LIABILITY Manufacturer warrants that on the Date of Purchase this Product will conform to Manufacturer's published specifications for the product, which are available from Manufacturer on request, and Manufacturer warrants that the product is free from defects in materials and workmanship. This Limited Warranty extends for twelve (12) months from the date of shipment.
FCC STATEMENT Additional Options: Custom System Configurations – Thanks to the advanced engineering by the Preco Engineers, the technology behind PreView Sensors can easily integrate or control your machines existing or new safety systems. This device complies with Part 15 of the FCC Rules.
Troubleshooting: Display will not turn on: Verify that DC power (9-33V) is applied to the display. Verify that the display has a solid ground connection. Display cannot find or connect to the wireless sensor: Verify that DC power (9-33V) is applied to the sensor. Sensor may be out of range. Contact Preco Electronics for assistance. “Not In Reverse” message is present, but machine is in reverse: Verify display and sensor are configured properly, see page 6.
Contents Specifications: DISPLAY SPECIFICATIONS (Typical) Housing Material: CYCOLOY LG9000, TILO 1310 TPE Dimensions: 3.36”H x 3.60"W x 1.34"D (8.5cm x 8.4cm x 3.4cm) Weight: 0.27 lb. (0.12 kg) Mounting: User dependent, ¼-20 thread ELECTRICAL SPECIFICATIONS Input Voltage: 9-33VDC, over voltage protected to 150V Input current: 0.
Connection to Sensor Failed Screen: If installation method “A” (display wired to ignition and reverse) was used and the sensor does not communicate with the display when the machine is placed into reverse, the home screen will show a “Connection to Sensor Failed” (Figure 3.4) error. If installation method “B” (display wired only to ignition) was used and the sensor does not communicate with the display, the display will continue to show the “Not In Reverse” message (Figure 2.
When the sensor reports a detection within the maximum detection range set in the “Distance Alert Screen” (page 7), the check mark will be replaced by a yellow triangle (Figure 3.2). The audible will also change to the “Warning” sound to notify you that an object has been detected. Active Screen, Warning (Figure 3.2) Installation: Installation of the system requires up to three electrical connections – ignition power, ground, and/or reverse.
Configuring the Display: Operation: Before configuring the display, the display and sensor (see sensor manual for sensor installation instructions) must be installed and powered. When the display is powered up, the Home screen will be present. Home Screen: The Home screen is present when the display is powered and the system is not active (Figure 2.1). Home Screen (Figure 1.1) Settings Icon Home Screen, Generic (Figure 2.
Settings Screen (Figure 1.3) Brightness Screen (Figure 1.10) Quick Guide to the Menu Icons: Volume adjustment Distance Alert Screen (Mandatory) The Distance Alert screen is used to set the visual and audible warning Connect a sensor to the display distances. The Distance Alert screen is entered by pressing the Change the passcode Adjust the icon. slide bar to set the maximum detection distance; the available Brightness adjustment range is between 10-20FT (3-6M).
Wired Connection Screen (Mandatory) In order for the system to operate as intended, the display must be told how it was electrically connected during installation. The Wired Connection Screen can be reached by pressing the Wireless Connect Screen 2 (Figure 1.7) icon. As discussed earlier, there are two wiring options for the display. Select the option that represents how the display was wired by pressing the corresponding blue box. Display Wired Connection Screen (Figure 1.