PRELIMINARY EHP19 Integrated Power Transceiver Installation and Service Manual 044-05210 Rev.
© 2005 Powerwave Technologies Incorporated. All rights reserved. Powerwave Technologies, and the Powerwave logo are registered trademarks. This Powerwave product is intended only for installation in a RESTRICTED ACCESS LOCATION. This Powerwave product is designed to operate within the normal operating (typical operating) ranges or conditions specified in this document.
Warnings, Cautions, and Notes Warnings, Cautions, and Notes are found throughout this manual where applicable. The associated icons are used to quickly identify a potential condition that could result in the consequences described below if precautions are not taken. Notes clarify and provide additional information to assist the user. WARNING: This warning symbol means danger. You are in a situation that could cause bodily injury or death.
Revision Record ii Revision Letter Date of Change Reason for Change Rev. A September, 2005 Preliminary Release 044-05205 Rev.
Chapter 1 Product Description 1.1 Introduction This manual contains information and procedures for the installation, operation, and maintenance of the EHP19 Integrated Power Transceiver (IPT). 1.2 Scope of Manual This manual is intended for use by service technicians familiar with similar types of equipment. It contains service information required for the equipment described and is current as of the printing date.
Functional Description from this block: control data and signal data. The control data determines parameters such as channel frequencies, signal ramp-up/ramp down and transmit power level. These functions are implemented in a Field Programmable Gate Array (FPGA). 1.3.2.2 Digital Up Converter (DUC) The DUC modulates individual symbol streams from the signal data stream on to baseband carriers and applies root-raised cosine channel filtering.
Functional Description FRONT REAR Figure 1-1 Integrated Power Transceiver Front and Rear Isometric View 1.3.3 Power Module The P-Mod is a multi-stage amplifier, which amplifies the low level signal from the AUC up to the RF output power level of +47.8 dBm (60.25 W). The P-Mod consists of a two-stage pre-driver, a driver amplifier and an output stage.
Functional Description 1.3.5 Operational States The IPT has three operational states: Operational, Disabled and Not Ready. The IPT remains in the Not Ready state during start-up until all parameters are met for the IPT to become operational. The IPT is normally in the Operational state: no faults are present, the IPT internal temperature is within limits, appropriate DC power is applied, and the IPT is producing RF output. The green operational (O) LED on the Man Machine Interface is lit.
Functional Description 044-05210 Rev.
This page intentionally left blank. 1-6 044-05210 Rev.
Chapter 2 Installation 2.1 Introduction This chapter contains unpacking, inspection and installation instructions for the EHP19 Integrated Power Transceiver (IPT). 2.2 • Carefully read and understand all material in the chapter prior to installation. • Review any government and local codes applicable to this installation. • Before operating the equipment, read the operating instructions in Chapter 3. Unpacking and Inspection Perform the steps in Table 2-1 to unpack and inspect the IPT.
Installation Instructions Table 2-2 IPT Installation Step Action 1 Carefully slide the IPT into the subrack. 2 Secure the IPT in the subrack by tightening the thumbscrews. 3 Connect the TX cable, RX0 and RX1 cables as shown in Figure 2-1. Transmit Output (TX) Receive 0 (RX0) Input Receive 1 (RX1) Input Figure 2-1 IPT Connector Locations 2-2 044-05210 Rev.
Chapter 3 Operation 3.1 Introduction This chapter contains operating instructions for the EHP19 Integrated Power Transceiver (IPT). 3.2 Controls and Indicators The IPT provides one switch, four LED indicators, one ethernet connector, one serial connector and two RS-485 connectors as shown in Figure 3-1. Figure 3-1 IPT Indicators and Controls 3.2.1 Reset Switch The Reset recessed pushbutton switch allows the operator to reset the IPT control circuits.
Initial Start-Up and Operating Procedures 3.2.2 Status and Alarm Indicators MCPA alarm conditions are reported to the system as logic level signals through the rear connector. The front panel LED provides a visual reference for the operator of MCPA status. Refer to Table 3-1. The IPT ALARM (INT.) lights when a IPT fault occurs.
Chapter 4 Maintenance 4.1 Introduction This chapter contains the periodic maintenance, troubleshooting and removal and replacement instructions for the EHP19 Integrated Power Transceiver (IPT). NOTE 4.2 Check your sales order and equipment warranty before attempting any service or repair activity. Do not break the seals on equipment under warranty or the warranty will be null and void.
Return For Service Procedures 4.4.1 IPT Removal and Replacement Procedure Perform the following to remove and replace the IPT: WARNING: Ensure the RF power has been removed from the RF input cable before disconnecting or reconnecting the RF input cable. Table 4-3 IPT Removal and Replacement Step 4.5 Action 1 DIsconnect cables at the TX, RX0 and RX1 inputs. 2 Loosen the thumbscrews and slide the IPT out of the subrack.
Chapter 5 Specifications 5.1 Power Amplifier Unit (IPT) Specifications Table 5-1 IPT Functional and Physical Specifications Frequency Range 1925 to 1995 MHz Instantaneous Bandwidth 5 MHz Total Typical / Maximum Input Power 2.9 dBm (1.9 mW) typical / 12.0 dBm (15.8 mW) maximum Total Output Power 26.3 watts typical / 33.1 watts maximum Adjacent Channel Leakage Power Ratio ACLR1 less than -33.5 dBc ACLR2 less than -54.8 dBc RF Gain 42.
in in Figure 5-1 Model EHP19 IPT Front View 5-2 044-05210 Rev A
in Figure 5-2 Model EHP19 IPT Side View 044-05210 Rev.
5-4 044-05210 Rev A
Chapter 5 Specifications 5.1 Specifications Table 5-1 IPT Functional and Physical Specifications Frequency Range 1930 to 1990 MHz Instantaneous Bandwidth 15 MHz Total Typical / Maximum Input Power N/A Total Output Power 60.2 watts (47.8 dBm) typical Adjacent Channel Leakage Power Ratio ACLR1 less than -33.5 dBc ACLR2 less than -54.8 dBc RF Gain N/A Gain Flatness Better than +/- 0.
290 mm 357 mm Figure 5-1 EHP19 IPT Side View 5-2 044-05210 Rev A
356 mm 59 mm Figure 5-2 EHP19 IPT Front View 044-05210 Rev.
5-4 044-05210 Rev A
Powerwave Installation and Service Manual Corporate Headquarters Powerwave Technologies, Inc. 1801 East St. Andrew Place Santa Ana, CA 92705 USA Tel: 714-466-1000 Fax: 714-466-5800 www.powerwave.com Main European Office Antennvägen 6 SE-187 80 Täby Sweden Tel: +46 8 540 822 00 Fax: +46 8 540 823 40 Main Asia-Pacific Office 23 F Tai Yau Building 181 Johnston Road Wanchai, Hong Kong Tel: +852 2512 6123 Fax: +852 2575 4860 ©Copyright March 2005, Powerwave Technologies, Inc. All Rights reserved.