930-1990 MHz Installation & Service Manual Model SPA9323-30C Single-Channel Cellular Amplifier © Copyright Powerwave Technologies, Inc., October 2004. All rights reserved 044-05178 Rev.
SPA9323-30C Installation & Service Manual © 2004 Powerwave Technologies Incorporated. All rights reserved. Powerwave Technologies, and the Powerwave logo are registered trademarks Powerwave Technologies, Inc. reserves the right to make changes to the documentation and equipment, including but not limited to component substitution and circuitry changes. Changes that impact this manual may subsequently be incorporated in a later revision of this manual.
SPA9323-30C Installation & Service Manual Table Of Contents Par. No. 1-1 1-2 1-3 1-4 Section 1 General Description Page No. Introduction ...................................................................................................................... 1-1 General Description ......................................................................................................... 1-1 Functional and Physical Specifications............................................................................
SPA9323-30C Installation & Service Manual Section 6 Troubleshooting 6-1 6-2 6-3 6-3.1 6-3.2 Introduction ...................................................................................................................... 6-1 Trouble shooting .............................................................................................................. 6-1 Return for Service Procedures ........................................................................................ 6-1 Obtaining an RMA............
SPA9323-30C Installation & Service Manual Section 1 General Description 1-1 Introduction This manual contains information and procedures for installation, operation, and maintenance of Powerwave’s SPA9323-30C (Nortel Model No. NTQA50GA) single-channel cellular amplifier. The manual is organized into six sections as follows: Section 1. General Description Section 2. Installation Section 3. Operating Instructions Section 4. Principles of Operation Section 5. Maintenance Section 6.
SPA9323-30C Installation & Service Manual Table 1-1 SPA9323-30C Single-Channel Cellular Amplifier Functional Specifications Frequency Range Nominal Input Power Total Output Power RF Gain at 882 MHz Gain Variation Over All Conditions: Output Protection: Input Port Return Loss: Out of Band Spurious: Spectral Mask Duty Cycle: DC Input Power: Heat Dissipation Operating Temperature: Storage Temperature: Operating Humidity: Storage Humidity: RF Input / Output Connector DC Power Connector Data I/O Connector Dime
SPA9323-30C Installation & Service Manual All dimensions are in inches and are for reference only Figure 1-1. SPA9323-30C Amplifier © Copyright Powerwave Technologies, Inc., October 2004. All rights reserved All specifications are subject to change without notice. Contact the factory for complete performance data. 1-3 October 2004 044-05178 Rev.
SPA9323-30C Installation & Service Manual Section 2 Installation 2-1 Introduction This section contains installation recommendations, unpacking, inspection, and installation instructions for the SPA9323-30C single channel cellular amplifier. Carefully read all material in this section prior to equipment unpacking or installation. Also read and review the operating procedures in Section 3 prior to installing the equipment. It is important that the licensee perform these tasks correctly and in good faith.
SPA9323-30C Installation & Service Manual Installation Instructions (Refer to figures 1-1 and 2-1) The SPA9323-30C is intended for installation in a Restricted Access Location. The SPA9323-30C amplifier module is designed for installation in a subrack that permits access to the amplifier’s front panel for connection of DC power, RF, and monitor cables. To install the amplifier proceed as follows: 1. Install amplifier in the BTS rack and secure in place. 2.
SPA9323-30C Installation & Service Manual 2-4.1 Data I/O Connector The amplifier has a separate remote alarm and control connector that may be used by the host system to monitor and control the individual amplifier modules. The status, alarm, and control connections on the amplifier connector are made through a 20-pin SCSI connector (figure 2-2) and are listed and described in table 2-1.
SPA9323-30C Installation & Service Manual 2-4.2 Amplifier RF Connectors The amplifier has two RF connectors. The RF Input connector is a SMA female. The input power on this port should not exceed the level specified in table 1-1. The RF Output connector is Type N female. They are listed and described in table 2-2. Table 2-2 Amplifier RF Connector Definition Function Description RF Input SMA Female RF Output Type N Female 2-4.
SPA9323-30C Installation & Service Manual Section 3 Operating Instructions 3-1 Introduction This section contains operating instructions for the single channel cellular amplifier system. 3-2 Location And Function Of Amplifier Indicators The front panel LED, located to the right of the 20-pin data connector, indicates the amplifier status. • Green indicates the amplifier is operating properly. • Red indicates an alarm or off condition.
SPA9323-30C Installation & Service Manual Section 4 Principles of Operation 4-1 Introduction This section contains a functional description of the single-carrier SPA9323-30C amplifier. 4-2 RF Input Signal The maximum input power should not exceed the levels to produce the maximum rated RF output power in table 1-1. This level is approximately –3.2 dBm, but should be set through the basetransceiver station’s software interface. See the BTS manual for detailed instructions.
SPA9323-30C Installation & Service Manual 4-4.1 Driver Amplifier The driver amplifier is a two-stage amplifier that provides approximately 28 dB of gain in the 60 MHz frequency band from 1930 to 1960 MHz. The amplifier is mounted directly on a heat sink, which is temperature monitored by a thermal sensor. 4-4.2 Main Amplifier The main amplifier is a single-stage Class AB amplifier with approximately 13 dB gain and a P1dB of +50 dBm. The amplifier’s output is protected from output mismatches.
SPA9323-30C Installation & Service Manual Section 5 Maintenance 5-1 Introduction The amplifier is designed to be operated without any periodic maintenance other than that recommended by the manufacturer of the BTS. Please consult your BTS manual for guidance. © Copyright Powerwave Technologies, Inc., October 2004. All rights reserved 044-05178 Rev.
SPA9323-30C Installation & Service Manual Section 6 Troubleshooting 6-1 Introduction This section contains a list of problems and a few suggested actions that may correct the problem. If the suggested corrective action does not eliminate the problem, please contact your Powerwave field representative or the factory for further instructions. NOTE Check your sales order and equipment warranty before attempting to service or repair the unit.
SPA9323-30C Installation & Service Manual Field Failure Report: RMA No.: __________ S/N: __________ Region: ________________ Customer: ___________________ Technician: ___________________ Manufacture Date: ___________ Failure Date: ___________ Phone No.