Operating Manual – PowerXchanger® Double Conversion AC Power Converter Step-Up Series 22050UX-1000 22050UX-1500 22050UX-2000 22050UX-3000 Input Range: 100 Vac ~ 285 Vac Input Frequency: 60Hz Output Range: 200V-220V-230V-240V Selectable Output Frequency: 50 Hz Read this manual before using PowerXchanger®. Failure to follow the instructions and safety precautions in this manual can result in serious injury or death. Keep this manual in a safe location for future reference.
CAUTION: ● The Converter connection instructions and operation described in the manual must be followed in the indicated order. ● Converter must be connected to a nearby wall outlet that is easily accessible. ● ● ● ● ● ● The Converter can be disconnected from the AC-power source by removing the power cord. DO NOT install the Converter near liquids or in an excessively damp environment. DO NOT let a foreign body penetrate inside the Converter. DO NOT block the ventilation grates of the Converter.
Special Symbols The following are examples of symbols used on the Converter to alert you the important information. RISK OF ELECTRIC SHOCK Indicates that a risk of electric shock is present, and the associated warning should be observed CAUTION; REFER TO OPERATOR’S MANUAL Refer to your operator’s manual for additional information, such as important operating and maintenance. SAFETY EARTHING TERMINAL Indicates the primary safety ground.
TABLE of CONTENTS 1. Overview and Features --------------------------------------------------------------------- Page 4 2. Presentation------------------------------------------------------------------------------------- Page 5 2.1 Front panel 2.2 Rear Panels -------------------------------------------------------------------------------------- Page 6~7 3. Installation--------------------------------------------------------------------------------------- Page 8 4.
1. OVERVIEW AND FEATURES This series is a double conversion Power Converter which produces stable pure sine wave voltage and frequency output (O/P). With the Converter, you can protect your equipment from most of the power problems, including power sags, power surges, brownouts, and line noise, etc.
2. PRESENTATION 2.1 Front panel The following shows the LCD Display: 1. Data Select 2. Main Control Button 3.
2.
UX-1500, UX-2000, UX-3000 Circuit Breaker Power Cord Cooling Fan EPO (Emergency Power Off) 7
3. INSTALLATION SAVE THESE INSTRUCTION. Please follow these instructions for installation and maintenance of the Converter. Please read all instructions before operating the equipment and save this manual for future reference. Increased ambient temperature will shorten the life of the Converter, keep the Converter away from heating elements. If ambient temperature is over 40℃, the load level will be reduced.
4. OPERATION 4.1 After installation with normal city power, the Converter will turn on automatically. Confirm the output voltage and frequency from LCD display by pressing the up/down select button. 4.2 Converter OFF: Pushing the main control button for 3 seconds, the Inverter will turn off the output voltage. The CPU will run “OFF(idle) mode when LCD shows ‘OFF’. 4.3 In idle mode, Converter will turn on again when the main control button is pushed for 1 second.
4.4.1 To change the Converter O/P frequency When the frequency value is blinking, push any selection button, △ or ▽, for 1 second to change the frequency setting! The setting will keep changing every 2 seconds if you keep pushing the button. Push two selection buttons at the same time for next setting, or leave the LCD blinking without pushing any button for 30 seconds to end the setting. 4.4.
5. INDICATION AND CONTROL 5.1 LCD Display The Converter LCD display shows the input voltage, output voltage, output frequency, output load level, and temperature. 5.2 Thermal Protection If the Converter detects that it is starting to overheat, it will sound a sequence of 32 beeps every two seconds. The LCD will show high temperature symbol when the inside is too hot. If the Converter continues to overheat, it will eventually turn itself off to protect itself from damage.
5.4 Output Overload Alarm The Converter can accept up to 129% of full load(See spec. for each model's rating) before continuous alarm sounds. If the output current drawn by the load exceeds the Converter’s over current alarm threshold, the CPU timer will start to count. If the overload continues for more than one minute an audible alarm will sound as long as the overload is present. If the overload alarm continues for more than one minute, the Converter will turn off the output.
6. SPECIFICATIONS Output STEP-UP Voltage and Frequency Converter (UX-URX series) 1000VA/ 1500VA / 2000VA / 3000VA UX-1K /UX-1.5K /UX-2K /UX-3K Capacity 1000VA/900W 1500VA/1350W Output Voltage 2000VA/1800W 3000VA/2700W 200V/220V/230V/240V Selectable Voltage Waveform Sine wave Crest Factor 3:1 Output Frequency (sync to mains) 50/60Hz (selectable from LCD function button) Output Frequency (not sync to mains) 50±0.01Hz or 60±0.
Transit/storage Temp. -15℃ to 55℃ (5℉ to 131℉) Relative Humidity 5 - 95% non-condensing Operating Altitude 0 ~ 3000 meters Audible Noise ≦45 dBA(at 1 meter from surface of unit) Safety Markings BSMI Quality Control System CE ISO9001 Physical Unit Dimensions DxHxW Unit Weight Shipping Dimensions D x H x W; Weight UX-1K: 38×22×18cm 15×9×7in UX-1.5K: 45×22×18cm 18×9×7in UX-2K: 51×22×18cm 20×9×7in UX-3K: 51×22×18cm 20×9×7in UX-1K: 6.5kg 14 lbs UX-1.5K: 7kg 15.
LIMITED WARRANTY Adaptive Frequency Inc. warrants for two years from the date of shipment, the product is free of manufacturing defects and conforms to Adaptive’s product specifications in force as of the date of manufacture of the product shipped.
LIMITED LIABILITY Adaptive Frequency Inc.
Copyright © 2021 Adaptive Frequency, Inc. Document 1.