User Manual Model No: PN2000 Thank you for purchasing the Electricity Usage Monitor by Poniie. Please read this manual carefully before using this product.
The device can measure Watts (active power), Current (true RMS), Voltage (true RMS), Frequency, Cumulative Time (with hold over circuit memory), Electricity Consumption (with hold over circuit memory) and Power Factor (as Watts/Vrms*Arms). How to calculate your dollar cost of energy consumption over a period? Plug the PN2000 device into the outlet, then plug the electric appliance which you want to test into the Power Monitor. It will start measuring the kilowatts used over a measured period of time.
1. Be sure to read, understand and comply with all the instructions in this manual. 2. Before using this product, check to see if there is any crack or short of plastic parts on the shell, pay attention to the insulation around the connectors. Please do not use the product if it is damaged. 3. DO NOT use the device on anything that could possibly have a surge amp rating greater than 16 amp. The loading power of electrical appliances cannot exceed the rated power of this product (1840W at 115V). 4.
1. There are four functional buttons on the product “▼”, “▲”, “SET” & “OK” 2. LCD display is shown as above. 1. Device startup/shutdown Directly plug the monitor into the power supply socket, and connect to commercial power to start the device; disconnect the power supply to shut down. 2.
Under the “CUR” display interface, press “SET” for 2 seconds to enter backlight setting interface. It will display “LEd” after entering the interface, and the “ON or OFF” is flickering (as shown in Figure 1). At this time, you can select to turn “ON or OFF” by pressing “▼” or “▲” button momentarily, and after selection, press the “OK” to exit setting.
How to clear EC and CT data? Respectively switch to EC and CT monitoring interface. Press “SET” for 2s, the cumulative electricity consumption value and time will flicker. Press “OK” to reset. 3 Watts and Current ○ A E A Respectively switch to Watts (WATT) monitoring interface (as shown in Figure 4) and Current (CUR) monitoring interface (as shown in Figure 5) by pressing “▼” or “▲”, the measuring display ranges shall be above 0.20W and 1.000-16.000A (It displays mA when under 1A).
by pressing “▼” or “▲”, the measuring display ranges shall be 110.0-260.0V and 40.00-60.00Hz respectively. 5 Power Factor and Overload Indication ○ A E A Switch to Power Factor (PF) monitoring interface (as shown in Figure 8) by pressing “▼” or “▲”, the measuring display ranges shall be 0.001-1.000. Overload indication setting: After long pressing ”SET” on the Watts display interface for 2 seconds, the thousand-digit on LCD will flicker, then enter overload indication limit setting.
Note: The default factory value is 1800W (16A, 115V), you can set your own limit if needed. When the power of the electrical appliance exceeds the setting limit, the backlight will flicker to indicate overload (as shown in Figures 9), please turn off the power and remove appliance immediately. Applicable power supply 110-220V 50/60Hz Maximum rated current 16A Maximum power 1840W(@115V) / 3520W(@220V) Measurable range 0.
•1 x PN2000 Digital Electricity Monitor •1 x User Manual •1 x 1 Ft. 14AWG Extension Cord IMPORTANT: 1) It is not recommended a long uninterrupted use for loads over 15 amp (1725W at 115V). 2) Please do not overload (1840W at 115V) the device at any time. Failure to comply with the instructions given in this manual and/or using the device in ways other than the ones mentioned in this manual may result in serious injury and/or damage to the product. 3) The inner and outer device material is ABS fireproofing.