User Manual Model No: PN2000 Thank you for purchasing the Electricity Usage Monitor by Poniie. Please read this manual carefully before using this product. Note: Remove the soft protective film (if any) on the screen. The film itself may seems like have some scratches, but you can peel it off if needed.
The PN2000 can measure Watts (active power), Current (true RMS), Voltage (true RMS), Frequency, Cumulative Time (CT with power off memory), Electricity Consumption (EC with power off memory) and Power Factor (as Watts/Vrms*Arms). How to calculate your dollar cost of energy consumption over a period? Plug the PN2000 into the power socket, and then plug the appliance to be tested into the monitor. It will start measuring kilowatts used over time.
1. Before using this product, check the shell for cracks or shortage of plastic parts, pay attention to the insulation around the connector. Do not use if damaged. 2. DO NOT overload wall outlets, extension cords, or integral convenience receptacles as this can result in a risk of fire or electric shock. 3. DO NOT use for long periods near the maximum rated current (in most cases, the true RMS current will be around 15A) to avoid any unnecessary damage or accident. 4.
1. There are four functional keys on the product “▼”, “▲”, “SET” & “OK” 2. LCD display is shown as above. 1. Device Startup/Shutdown Plug the monitor directly into the power socket and connect to AC power to start the device; disconnect the power supply to shut down. 2.
Under the “CUR” display, press “SET” key for 2 seconds to enter the backlight setting. After entering the interface, "LEd" is displayed, and the “ON or OFF” is flickering (as shown in Figure 1). At this time, you can select to “ON or OFF” by pressing “▼” or “▲” key, after selection, press the “OK” key to exit setting. “OFF” means that the backlight will turn OFF automatically when the device is not operated by the keys within 10 seconds (factory setting for fault); ON” means the backlight is always on. 3.
the measurement display range is 0.00-99999KWH and 0-99999 minutes respectively. The measured power consumption will be automatically stored and will not be lost even after a long period of power failure, which is good for circuits that loose power. Note: CT do not means the elapsed time on PN2000 model, it is calculated only when there is load (cumulative working time of testing appliance). How to clear EC and CT data? Press "▼" or "▲" button until switched to EC and CT monitoring interface.
4 Voltage and Frequency ○ A E A Press “▼” or “▲” to switch to the voltage (volt) monitoring interface (as shown in Figure 6) and frequency (FREQ) monitoring interface (as shown in Figure 7). The measurement display range is 100-240.0 v and 40.00-60.00Hz respectively. 5 Power Factor and Overload Indication ○ A E A Press “▼” or “▲” to switch to Power Factor (PF) monitoring interface (as shown in Figure 8), the measuring display ranges is 0.001-1.000.
then enter the overload indication limit setting. Press “▼” or “▲” to adjust the value, after finishing the thousands of digits adjustment, press" SET "to set the hundreds of digits, and so on. Remember to press “OK” at the end to exit the Settings mode. Note: The default factory value is 1800W, and you can set the limit yourself if necessary. When the power of the appliance exceeds the set limit, the backlight flashes to indicate overload (as shown in Figures 9).
•1 x PN2000 Electricity Usage Monitor •1 x User Manual •1 x 1 Ft. 14AWG Extension Cord IMPORTANT: 1) Please do not overload the device at any time. Failure to comply with the instructions given in this manual and/or using the device in ways other than the ones mentioned in this manual may result in serious injury and/or damage to the product. 2) The material of the inner and outer parts is ABS fireproofing.