User's Manual

FCC ID: M5ZVM1
Installation and Operation Instructions for the Wireless Vibration Sensor.
Point Six, Inc.
Wireless Vibration Sensor Model Point Sensor
Vibration
Installation and Operation Instructions
The Point Sensor Vibration wireless pressure sensor transmits a digital value representing
vibration, or other vibration levels from various range sensor elements and a unique serial
number to a 418 MHz receiver. The Point Sensor Vibration is enclosed in a high impact
ABS enclosure for direct surface mounting in the environment to be measured. Point
Sensor Vibration is battery operated, the battery may be replaced by the user.
Application: Apply the sensor to a surface to with double-sided adhesive tape. Make
sure that the side labeled with FCC ID is visible and away from any metal surfaces.
Service Function: The wireless vibration sensor has an installation mode switch. A
momentary push of this switch will start the convert/transmit cycles. When new and until
this button is pushed the Point Sensor Vibration will not transmit. The Point Sensor
Vibration will transmit a special installation status mark in the data packet immediately
after the installation/start switch is pushed. After the start a push of the installation
switch will result in the immediate transmission of data and ID and installation status
mark.
Battery: A 3.6 Volt lithium battery powers the Point Sensor Vibration wireless sensor.
The battery will last for more than 10 years in the idle state (as shipped from the
manufacturer). The Point Sensor Vibration will transmit data for as long as 3 years at a
rate of once each 30 seconds once started. The Point Sensor Vibration is completely
covered with a conformal coating to protect the electronics from the environment and
condensation. The Point Sensor Vibration may be placed in a quiescent state (battery life
greater than 10 years) by holding the installation switch closed for more than 5 seconds.
THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES, OPERATION IS
SUBJECT TO THE FOLLOWING TWO CONDITIONS: (1) THIS DEVICE MAY
NOT CAUSE HARMFUL INTERFERENCE AND (2) THIS DEVICE MUST ACCEPT
A
NY INTERFERENCE RECEIVED, INCLUDING INTERFERENCE THAT MAY
CAUSE UNDESERED OPERATION
FCC ID: M5ZVM1
MADE IN USA