User Manual

Point Six, Inc. 2333 Alumni Park Plaza - Lexington, KY - 40517- http://www.pointsix.com - 859-266-3606 - Fax 859-266-0702
FCC ID: M5ZIRPROX2
Installation and Operation Instructions for the IR Proximity Counter.
Point Six, Inc.
Wireless IR Proximity Counter Model IRPROX2
Installation and Operation Instructions
Description
The new IRPROX2 people counter has a battery life of >2years. The pushbutton on the sensor has the following
functions:
Power Down: Press and hold the button for > 8 Seconds.
Test power state: Press briefly; LED comes on to indicate power down state.
Power Up : Press for >2 seconds and <8 seconds, LED goes out.
Transmit service packet: Briefly press while powered up.
IR Program: Press and hold the button for >8 seconds while sending IR program parameter commands from IR
transmitter attached to the serial port of a PC running Prox-Programmer software. When an IR command is properly
received and processed the LED will flash to indicate success.
This model has IR ranges of 6,4,3 and 2 feet, switch selectable.
The IR programmability includes:
In-beam time in ¼ second steps to 255 steps. Default: ¼ second.
Out-of-beam time in ¼ second steps to 255 steps. Default: 1 second.
Blocked beam time in ¼ second steps to 255 steps. Default: 16 seconds.
LED flash enable/disable during count. Default: LED flash.
Packet type enable/disable for automatic inclusion of the switch data in a new device type, type "09" the standard
people counter is type "11"
Note: IR programmed parameters are stored in EEPROM and are not lost when replacing the battery.
Note: the LED flashes at other times as normal even if disabled to flash during count.
Note: The packets are micro-randomized for 10 seconds +- 7 (1/4) second intervals.