PIRAMID XL3 US PIRAMID XL3 DUAL-TECHNOLOGY SENSOR Installation instructions - Pages 1-28 529 VISTA BLVD 89434 SPARKS, NV - USA Toll Free: 1-800-498-9662 / Phone: (775) 856-7333 / Fax: (775) 856-7658 Website: www.protechusa.com E-mail: sales@protechusa.com NT412 / V1.2 / 09.
PROTECH PIRAMID XL3 CONTENTS 1 GENERAL .............................................................................................................2 2 DESCRIPTION ......................................................................................................3 3 OPERATION .........................................................................................................4 4 INSTALLATION PRECAUTIONS ..........................................................................
PROTECH 1 PIRAMID XL3 GENERAL PIRAMID XL3 is a dual-technology sensor: • A passive infrared unit composed of a pyroelectric infrared (PIR) sensor that detects radiation emitted by the human body in the infrared spectrum. • A Microwave antenna using a 10,510 GHz frequency transmitter and a Doppler Effect receiver detect changes in the state of the radiation field caused by passage of an object or body in the lobe created by the antenna.
PROTECH 2 PIRAMID XL3 DESCRIPTION PIR Lens MW antenna cover Front view Back view Top view Side view -3-
PROTECH 3 PIRAMID XL3 OPERATION Characteristics of detection zone: SDI-78XL3-A SDI-78XL3-B Top view 98 ft / 30 m 33 ft / 10 m Top view 98 ft / 30 m Side view lens B 98 ft / 30 m Side view lens A Side view lens B-Pet Side view lens A-Pet SDI-78XL3-C SDI-78XL3-D Top view 19.7 ft / 6 m 9.
PROTECH PIRAMID XL3 SDI-78XL3-H SDI-78XL3-H60 Top view 85.3 ft / 26 m 45.9 ft / 14 m Top view 98.4 ft / 30 m Side view 98.4 ft / 30 m Side view SDI-78XL3-H40 SDI-78XL3-H20 Top view 23 ft / 7 m 3m Top view 98.4 ft / 30 m Side view 98.
PROTECH 4 PIRAMID XL3 INSTALLATION PRECAUTIONS It is important to follow certain rules to ensure proper installation of the detector: - ENSURE THAT NO VEGETATION IS FOUND IN THE DETECTION ZONE. CHECK THAT THE CLOSEST VEGETATION DOES NOT OBSTRUCT THE DETECTION ZONE IN CASE OF WIND. DON’T RESPECT THE RECOMMENDED INSTALLATION HEIGHT. Installation height must be between 6.
PROTECH - PIRAMID XL3 INSTALL THE DETECTOR ON A STABLE MOUNTING SURFACE DON’T mount the detector on a surface exposed to strong vibrations, such as a fence with no support or a flimsy metal surface. DO: Mount the detector on a wall or solid post If it is installed on a building with a metal surface, the support must be vibration-resistant.
PROTECH PIRAMID XL3 DON’T leave any bin in the range of the detector which could attract small animals and birds. When they are near to the detector, they may be identified as larger targets by the detector. DO: Place bins away from the range of the detector. DON’T DO Rubbish - Rubbish BE CAREFUL OF BIRDS WHICH COULD PERCH IN THE RANGE OF THE DETECTOR DON’T install the detector near to lighting fixtures or signage. They can be used as perches by birds and trigger false alarms.
PROTECH - PIRAMID XL3 BE CAREFUL OF ANIMALS PASSING THROUGH HOLES IN OR DUG UNDER A FENCE DON’T ignore openings which have been made in a fence and may provide an easy passage for small animals (dogs, cats, raccoons, etc.) in the protected area. DO: Repair holes in the fence (or fill in holes dug underneath) to block access to the protected area. DON’T DO - - WARNING IF INSTALLING THE SENSOR UNDER EAVES DON’T mount the detector under eaves which are not equipped with a gutter.
PROTECH INSTALLATION For optimum performance, the PIRAMID XL3 detector must be installed at a height between 6.6ft / 2m and 13ft / 4m. Drilling template for wall mounting: 2.4 in / 60mm REQUIRED ACCESSORIES TO MOUNT PIRAMID XL3: 3.2 in / 80mmm - 2,8 in 70 mm Drilling template for corner mounting: 2,8 in 70 mm 0,4 in 10 mm 5 PIRAMID XL3 ,7 19 m in m in 0,7 mm 19 - 10 - 4 Screws 4.
PROTECH PIRAMID XL3 Opening the cover Loosen the screw, raise, and then pull the cover up. 6 WIRING 6.
PROTECH PIRAMID XL3 6.2 Maximum length of 12VDC power supply cables (Wire type SYT1 shielded) ∅ Wire 0.02 in 0.6 mm 0.04 in 0.9 mm 0.06 in 1.4 mm Wire section 23 AWG 0.3 mm² 20 AWG 0.6 mm² 16 AWG 1.5 mm² Maximum length of cables 0.06 mi 94 m 0.13 mi 211 m 0.29 mi 470 m Note: When using the same cable to supply power to several components, the indicated distances should be divided by the number of connected components.
PROTECH PIRAMID XL3 1. Turn the “Test Mode” switch to the ON position to change to Settings mode. 2. Set the sensitivity to maximum (code selector set to 9). Code selector sensitivity setting 3. Set the maximum distance beyond which the PIRAMID XL3 should not detect. Code selector setting Max. distance Code selector value 1 2 3 4 5 6 7 8 9 Distance 16.
PROTECH PIRAMID XL3 4. Turn the product on, the PIR and MW LEDs will light up when the initiation phase has ended (5s). ALARM LED PIR LED MW LED 5. Determine the desired PIRAMID XL3 detection range by performing walk test in this area. Adjust detector orientation and sensitivity to the required settings. When one of the technologies, PIR or MW, switches to alarm status, the associated LED will light up red. When both PIR + MW technologies are in alarm status, the ALARM LED will light up red.
PROTECH PIRAMID XL3 6. Turn the "Test Mode" to the OFF position to switch to detection mode. 7. Close the cover. 8. In normal operation, the LEDs are off. It is possible to activate them via smartphone application (see §8.2). Note: “INTRUSION” and "MASKING” relays remain in alarm status when the "Test Mode" switch is in the ON position. 7.2 Anti-masking alarm The alarm is triggered when an obstacle obstructs the masking sensor located in the upper cover.
PROTECH PIRAMID XL3 7.3 Reading the parameters of the PIRAMID XL3: "READ" Mode Sensitivity and distance settings max. can be modified: - Either via the code selectors on the detector - Or via the smartphone application Note: In Settings mode, sensitivity and distance settings are stored in memory by the code selectors. In Detection mode, sensitivity and distance settings are stored in memory either by the application: last backup performed.
PROTECH PIRAMID XL3 4. Turn the code selector until the LED is permanently lit. The value displayed on the code selector corresponds to the stored setting. 5. Turn the "Test Mode" switch OFF to exit “Read” mode. 8 SMARTPHONE APPLICATION Note: The smartphone application is compatible from Android 4.1 or higher. 1. Download the “Sorhea Connect” smartphone application. Sorhea Connect 2. Launch the “Sorhea Connect” application. Authorize activation of Bluetooth if requested to do so by the application.
PROTECH PIRAMID XL3 4. Set a tamper alarm to activate the BLE connection with the smartphone application: leave the tamper contact pressed down for 2 seconds, then release. Note: the connection remains active for as long as the PIRAMID XL3 is connected to the smartphone application. It is disconnected when the cover is shut (tamper contact closed) or after 1 minute of inactivity (application closed). Tamper contact 5. Launch the search. 6. Click on the product found.
PROTECH PIRAMID XL3 8.1 Managing settings Setting the time on the PIRAMID XL3 Name of PIRAMID XL3: Click on the name to change it then click on Save. 8.2 PIRAMID XL3 settings 1. Click on Menu Menu 2.
PROTECH PIRAMID XL3 3. PIRAMID XL3 settings Legend: Enable Disable Sensor ejected Sensor not ejected LEDS enabled / disabled Buzzer enabled / disabled Relay outputs enabled / disabled Antimask enabled / disabled MW ejection PIR ejection Moving direction: Settings save above MW Range settings 1 : 16 ft / 5 m 9 : 148 ft / 45 m MW Sensitivity settings 1 : Not very sensitive 9 : Very sensitive Max. speed settings: 0.62 to 31 mph / 1 to 50 km/h Distance to be covered settings: 0.33 to 16 ft / 0.
PROTECH PIRAMID XL3 8.3 Real-time Information 1. Click on Menu Menu 2. Click on Real-time Real-time 3.
PROTECH PIRAMID XL3 8.4 Event log 1. Click on Menu Menu 2.
PROTECH PIRAMID XL3 3.
PROTECH 9 PIRAMID XL3 PERIODIC MAINTENANCE To guarantee performance over time, basic maintenance operations should be performed to confirm the status of the PIR filter. If necessary, clean the filter with a soft, moist cloth. 10 MAINTENANCE Default settings: - LEDs status Buzzer status : disable : enable Failure Permanent alarm No triggering of the intrusion alarm Anti-masking alarm in permanent alarm (see §8.2 for led settings) (see §8.
PROTECH PIRAMID XL3 11 TECHNICAL SPECIFICATIONS Maximum outdoor range Detection mode Antenna MW frequency Power supply voltage Power supply current Typical intrusion alarm duration Typical anti-masking alarm duration NC Tamper relay rating NC Intrusion relay rating NC Anti-masking relay rating Operating temperature Relative humidity Protection Index Weight Electromagnetic compatibility Detector orientation SDI-78XL3-A: 98ftx98ft / 30mx30m SDI-78XL3-B: 98ftx33ft / 30mx10m SDI-78XL3-C: 131ftx19.
PROTECH PIRAMID XL3 12 PRODUCT REFERENCES • • • • • • • • • • • • • • SDI-78XL3-A range 98x98ft / 30x30m white SDI-78XL3-B range 98x33ft / 30x10m white SDI-78XL3-C range 131x19.7ft / 40x6m white SDI-78XL3-D range 131x9.8ft / 40x3m white SDI-78XL3-A PET range 98x98ft / 30x30m white SDI-78XL3-B PET range 98x33ft / 30x10m white SDI-78XL3-C PET range 131x19.7ft / 40x6m white SDI-78XL3-A range 98x98ft / 30x30m gray anthracite SDI-78XL3-B range 98x33ft / 30x10m gray anthracite SDI-78XL3-C range 131x19.
PROTECH PIRAMID XL3 ISED Licence-Exempt Radio Apparatus This device contains license-exempt transmitter(s)/receiver(s) that comply with Innovation, Science and Economic Development Canada’s license-exempt RSS(s). Operation is subject to the following two conditions: 1. This device may not cause interference. 2. This device must accept any interference, including interference that may cause undesired operation of the device.
PROTECH PIRAMID XL3 In compliance with the European environmental directives, this product must not be thrown away but recycled through an appropriate subsidiary.