Retrofit Instruction

UST106 Pro
PREPARATORY MEASUREMENTS AND ADJUSTMENTS:
The following adjustments are recommended to ensure that the transmitter
is working properly before any changes are made.
1. Measure the output of the up-converter and be certain the level is set at
+24dBm. The front panel Power adjustment knob should vary the +24 dBm by
+1 to -4 dB only. If the output is out of range adjust the variable resistor (see the
UST-106A instruction Manual) on the upconverter to insure that the proper range
is maintained. This is important to protect the power amplifier from damage by
overdrive. Over drive damage is not covered by warranty.
2. Measure the purity of the up-converted signal. This measurement is made
to insure that the mixing products are at least
-60dBc or better. The power
amplifier is broadband and will amplify these unwanted signals making filtering
necessary if they are out of specs to start with.
3. Adjust the aural/visual ratio to -13 dB (5%). This is a typical setting for
most applications, however, the Power Amplifier can be used at higher levels if
necessary with only minor degradation in performance.
***WARNING***
BEFORE REMOVING ANY PARTS OR WIRE, THE TRANSMITTER OR
TRANSPOSER MUST BE TURNED OFF AND DISCONNECTED FROM
THE PRIMARY AC POWER SOURCE. ALL OTHER EXTERNAL
CONNECTIONS INCLUDING ANTENNA MUST BE DISCONNECTED.
USE A GROUNDING ROD TO DISCHARGE ANY RESIDUAL CHARGES
FROM THE HIGH VOLTAGE SUPPLY, CAVITY ECT. MOVE THE
EQUIPMENT AWAY FROM OTHER EQUIPMENT SO THAT THERE
WILL BE PLENTY OF ROOM TO WORK ON THE FRONT AND REAR
OF THE EQUIPMENT TO BE MODIFIED.
***WARNING***